B&R 8EI034HCSS0.XXXX-1

ACOPOS P3 servo drive, 3x 200-480 VAC, 34 A, SafeMOTION

MPN
8EI034HCSS0.XXXX-1
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the B&R 8EI034HCSS0.XXXX-1?

ACOPOS P3 servo drive, 3x 200-480 VAC, 34 A, SafeMOTION, 1 axis, AS, cold plate or pass-through mounting

Specifications

General information

Support – Dynamic node allocation (DNA)Yes
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ULcULus E225616; Power conversion equipment
Slots for plug-in modules1

Mains connection

Terminal connection cross section – With wire end sleeve0.75 to 16 mm²
Terminal connection cross section – UL/C-UL-US20 to 4 AWG
Terminal connection cross section – CSA20 to 4 AWG
Network configurationsTT, TN, TN-S, TN-C-S, IT (note: Operation on TT and IT power systems and on TN power systems that are not grounded to a star point is only permitted for 8EI servo drives with 8ZELxxxx Rev. D0 and higher. See the device information on the left side cover of the 8EI servo drive. Remove IT jumper X10 before operating in IT networks!)
Mains input voltage3x 200 VAC to 480 VAC ±10%
Frequency50 / 60 Hz ±4%
Installed loadMax. 26.4 kVA
Inrush currentMax. 100 A
Switch-on interval120 s
Integrated line filter per EN 61800-3, category C3No (note: A line filter must be connected. CE compliance can only be ensured by connecting an upstream B&R line filter (8B0F...). In extreme cases, using line filters from 3rd-party manufacturers can result in irreparable damage to the ACOPOS P3 8EI servo drive.)
Power dissipation at device nominal power without braking resistor[81 W + 9.7 V * I + 8.4 W/kW * P out + 0.25 Ω * I 2 BR + P VSLOT ] * 1.1
Power dissipation remaining in the control cabinetPv_inside = 0.510 * Pv + 1.624 * (T_amb – T_inside)
Max. line length3 m (note: Maximum line length between line filter and mains connection on the module.)

DC bus connection

Reduction of continuous power depending on mains input voltage – Mains input voltage <3x 400 VAC14 kW * (Mains input voltage [V] / 400 V)
Terminal connection cross sections – With wire end sleeves0.75 to 16 mm²
Terminal connection cross sections – UL/C-UL-US20 to 4 AWG
Terminal connection cross sections – CSA20 to 4 AWG
Continuous power14 kW (note: Valid for mains input voltage ≥3x 400 VAC. The sum of the continuous power values on all motor connections and the power of the DC bus connector is not permitted to exceed this value.)
DC bus capacitance1680 µF
Max. line length3 m (note: This value applies to unshielded wiring inside a control cabinet. Maximum length of the DC bus wiring inside a control cabinet.)

24 VDC power supply

Terminal connection cross sections – With wire end sleeves0.25 to 4 mm²
Terminal connection cross sections – UL/C-UL-US24 to 8 AWG
Terminal connection cross sections – CSA24 to 8 AWG
Input voltage24 VDC ±25%
Input capacitance5500 μF
Current consumption2 A + Current for motor holding brake (note: Current consumption depends on the respective configuration of the ACOPOS P3 8EI servo drive. The inrush current of the 24 VDC power supply is not limited by the module.)
Max. line length30 m

Motor connection

Accuracy of the safe current – SIL 2 / PL d / Cat. 3Hardware upgrade 1.10.2.x: 9.098 A; Hardware upgrade 1.10.3.0 or later: 7.614 A
Accuracy of the safe current – SIL 2 / PL d / Cat. 23.804 A
Accuracy of the safe current – SIL 2 / PL d / Cat. 3Hardware upgrade 1.10.2.x: 7.732 A; Hardware upgrade 1.10.3.0 or later: 6.196 A
Accuracy of the safe current – SIL 2 / PL d / Cat. 22.666 A
Reduction of continuous current depending on ambient temperature – Switching frequency 5 kHzIn preparation
Reduction of continuous current depending on ambient temperature – Switching frequency 10 kHzIn preparation
Reduction of continuous current depending on ambient temperature – Switching frequency 20 kHzIn preparation
Reduction of continuous current depending on ambient temperature – Switching frequency 5 kHzIn preparation
Reduction of continuous current depending on ambient temperature – Switching frequency 10 kHzIn preparation
Reduction of continuous current depending on ambient temperature – Switching frequency 20 kHzIn preparation
Reduction of continuous current depending on installation elevation – Starting at 500 m above sea level3.4 A eff per 1000 m
Protective measures – Overload protectionYes
Protective measures – Short-circuit and ground fault protectionYes
Variant – U, V, W, PEConnector
Variant – Shield connectionYes; Clamping range of the grounding clamp: 17 to 30 mm
Terminal connection cross section – With wire end sleeve0.75 to 16 mm²
Terminal connection cross section – UL/C-UL-US20 to 4 AWG
Terminal connection cross section – CSA20 to 4 AWG
Max. motor line length depending on switching frequency – Switching frequency 5 kHz75 m
Max. motor line length depending on switching frequency – Switching frequency 10 kHz35 m
Max. motor line length depending on switching frequency – Switching frequency 20 kHz20 m
Quantity1
Continuous power per motor connection14 kW (note: Valid under the following conditions: 560 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.)
Continuous current per motor connection34 A eff (note: Valid under the following conditions: 560 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.)
Peak current per motor connection85 A eff
Peak power output35 kW
Nominal switching frequency5 kHz
Possible switching frequencies2.5 / 5 / 10 / 20 kHz (note: B&R recommends operating the module at its nominal switching frequency. Operating the module at a higher switching frequency for application-specific reasons reduces the continuous current and increases CPU utilization.)
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A (note: Only applies when using B&R motor cables and B&R motors.)
Max. output frequency598 HzPower unit: Limit speed exceeded").">

Motor holding brake connection

Terminal connection cross section – With wire end sleeve0.75 to 16 mm²
Terminal connection cross section – UL/C-UL-US20 to 4 AWG
Terminal connection cross section – CSA20 to 4 AWG
Protective measures – Overload and short-circuit protectionYes
Protective measures – Open-circuit monitoringYes
Protective measures – Undervoltage monitoringYes
Quantity1
Output voltageDepends on the input voltage on connector X2 (note: At values <22.9 V, under voltage monitoring is triggered and the servo drive signals error 6029 or 6055. In this case, the input voltage at connection X2 (24 VDC power supply) is too low and must be increased.)
Continuous current per connection6.5 A
Max. internal resistance0.25 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation15 Ws
Max. switching frequency0.5 Hz
Response threshold for open-circuit monitoringApprox. 120 mA
Response threshold for undervoltage monitoringApprox. 23 V
Max. breaking current SBC200 mA
Max. line length75 m (note: During configuration, it is necessary to check if the minimum voltage can be maintained on the holding brake with the intended line length. For the permissible operating voltage range of the holding brake, see the user documentation for the motor being used.)

Braking resistor

Protective measures – Overload protectionNo
Protective measures – Short-circuit and ground fault protectionShort-circuit protection: Yes; Ground fault protection: No
Peak power output45 kW
Continuous power4 kW
Minimum braking resistance (ext.)13 Ω
Max. line length3 m

Fieldbus

TypePOWERLINK V2 controlled node (CN)
Variant2x RJ45, shielded, 2-port hub
Line lengthMax. 100 m between 2 stations (segment length)
Transfer rate100 Mbit/s

Encoder interfaces

Electrical isolation – Encoder - ACOPOS P3No
Encoder power supply – Short-circuit proofYes
Encoder power supply – Overload-proofYes
Encoder power supply – Output voltageConfigurable; Typ. 11.45 V ±0.1 V / 5.2 V ±0.1 V
Encoder power supply – Load capacityMax. 300 mA
Encoder power supply – Sense lines2, compensation of max. 2x 0.7 V
Synchronous serial interface – Minimum2.0 V
Synchronous serial interface – Maximum6.0 V
Synchronous serial interface – Signal transmissionRS485 (note: Except encoder type HIPERFACE DSL.)
Synchronous serial interface – Data transfer rateDepends on the configured encoder type
Quantity1
TypeDigital multi-encoder interface, configurable (note: The encoder type is not predefined from the factory. The encoder type necessary in each case must be configured in Automation Studio.)
Connections8-pin female Mini I/O connector
Status indicatorsNone (note: The direction of rotation of the encoder can be displayed on the 8EAD0000.000-1 display module.)
Max. encoder cable length75 m ; Depends on the cross section of the power supply wires in the encoder cable
Max. power consumption per encoder interfaceP ENCODER [W] = U 24V [V] * (I ENCODER [A] * 0.7) + 0.5 W (note: I ENCODER ... Current consumption of the encoder U 24V ... Input voltage on the +24 VDC input of the module)

Trigger inputs

Electrical isolation – Input - ACOPOS P3Yes
Electrical isolation – Input - InputYes
Input voltage – Nominal24 VDC
Input voltage – Maximum30 VDC
Switching threshold – Low<5 V
Switching threshold – High>15 V
Switching delay – Rising edge<51 µs
Switching delay – Falling edge<52 µs
Terminal connection cross section – With wire end sleeve0.25 to 2.5 mm²
Terminal connection cross section – UL/C-UL-US26 to 12 AWG
Terminal connection cross section – CSA26 to 12 AWG
Quantity2
CircuitSink
Input current at nominal voltage7 mA
Modulation compared to ground potentialMax. ±38 V
Max. line length100 m

Temperature sensor connection

Quantity1
Resistance range500 Ω to 5 kΩ

Support

Motion system – mapp Motion5.05.0 and higher
Motion system – ACP10/ARNC05.03.0 and higher

Electrical properties

Energy efficiency (IE classification) – Power dissipation relative to continuous apparent powerIE2 (10,25) 1% ; IE2 (50,25) 1% ; IE2 (10,50) 1.2% ; IE2 (50,50) 1.3% ; IE2 (90,50) 1.4% ; IE2 (10,100) 1.9% ; IE2 (50,100) 2.1% ; IE2 (90,100) 2.4%
Energy efficiency (IE classification) – Nominal losses in standby mode15.8 W

Operating conditions

Permissible mounting orientations – Hanging verticallyYes
Permissible mounting orientations – Horizontal, face upNo
Permissible mounting orientations – Standing horizontallyNo
Installation elevation above sea level – Nominal0 to 500 m
Installation elevation above sea level – Maximum4000 m (note: For operation on phase-grounded/center-grounded delta networks (TT and TN) and IT networks, the value is reduced to 2000 m.)
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20 (note: The specified degree of protection is only met if either the slot cover is installed on the module or an 8EAC plug-in module is installed and suitable terminals are connected to all connectors and all fans are installed.)

Ambient conditions

Temperature – Minimum-25°C
Temperature – Nominal5 to 40°C
Temperature – Maximum55°C
Temperature – Storage-25 to 55°C
Temperature – Transport-25 to 70°C
Relative humidity – Operation5 to 85 %, non-condensing
Relative humidity – Storage5 to 95%
Relative humidity – Transport95% at 40°C

Mechanical properties

Dimensions – Cold plate281.5 mm (with 8EXA front cover: 284 mm) (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
Dimensions – Pass-through mounting277.5 mm (with 8EXA front cover: 280 mm) (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
Dimensions – Width133 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
Dimensions – Height374 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
Dimensions – Depth264.50 mm (with 8EXA front cover: 267 mm) (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
Weight9.4 kg

Accessories

Required accessories (order separately)

8EMC0060000.0000-2Cold-plate mounting — ACOPOS P3 mounting plate, 6 slots, cold plate mounting
8EMC0040000.0000-2Cold-plate mounting — ACOPOS P3 mounting plate, 4 slots, cold plate mounting
8EMC0020000.0000-2Cold-plate mounting — ACOPOS P3 mounting plate, 2 slots, cold plate mounting
8EXF500.0000-00Fan modules — ACOPOS P3 fan module for mounting plate 8EMFxxx0000.0000-1 single-width
8EXF400.0000-00Fan modules — ACOPOS P3 fan module for mounting plate 8EMFxxx0000.0000-1 double-width
Optional accessories (26)
8EAD0000.000-1Display modules — An 8EAD display module can be plugged into the X9 interface of an 8EI servo drive to display information about the drive and set its parame…
8EXF300.0000-00Fan modules — ACOPOS P3 ELKO fan module, replacement fan for ACOPOS P3 servo drive double-width (8EI017xxD/8EI022xxD/ 8EI024/8EI034/8EI044)
8EXF200.0000-00Fan modules — ACOPOS P3 fan module, replacement fan for ACOPOS P3 servo drive double-width (8EI017xxD/8EI022xxD/ 8EI024/8EI034/8EI044)
8EXA300.0020-00Front covers — 8EXA covers protect the interfaces on the front of ACOPOS P3 8EI servo drives and contribute to a uniform appearance inside the control cab…
8EXA300.0010-00Front covers — 8EXA covers protect the interfaces on the front of ACOPOS P3 8EI servo drives and contribute to a uniform appearance inside the control cab…
8B0F0550H000.000-1Line filters passive — Wide mains input voltage range; Optimally suited for ACOPOSmulti 8B0P power supply modules; Compliance with limit values per CISPR11, group…
8B0F0300H000.000-1Line filters passive — Wide mains input voltage range; Optimally suited for ACOPOSmulti 8B0P power supply modules; Compliance with limit values per CISPR11, group…
8B0F0160H000.000-1Line filters passive — Wide mains input voltage range; Optimized for ACOPOSmulti 8B0P power supply modules and ACOPOS P3; Compliance with limit values per CISPR11…
8EAC0152.001-1Plug-in modules — ACOPOS P3 plug-in module, analog multi-encoder interface
8EAC0151.001-1Plug-in modules — ACOPOS P3 plug-in module, incremental encoder interface
8EAC0150.001-1Plug-in modules — ACOPOS P3 plug-in module, digital multi-encoder interface
8EAC0130.000-1Plug-in modules — ACOPOS P3 plug-in module, 8 digital I/O 24 V (4x 400 mA, 4x 100 mA) individually configurable as inputs or outputs, 2 digital I/O 24 V 2 A…
8EAC0122.001-1Plug-in modules — Resolver interface for installation in ACOPOS P3 servo drives; Encoder monitoring; High resolution ACOPOS P3 plug-in module, resolver inter…
8SCSE02.0200-00Shield component sets — ACOPOS P3 shield component set: 1x shield connection clamp type SK20
8SCSE02.0100-00Shield component sets — ACOPOS P3 shield component set: 1x shield connection clamp type SK14
8SCSE01.0200-00Shield component sets — Shield component set 8SCSE01.0200-00 is installed on the underside of ACOPOS P3 8EI servo drives with a width of 133 mm and consists of a s…
8TB4104.227F-10Terminal blocks — 4-pin push-in terminal block, 1-row, pitch: 10.16 mm, label 4: DC-, DC-, DC+, DC+ coding F: 0101
8TB4104.224G-10Terminal blocks — 4-pin push-in terminal block, 1-row, pitch: 10.16 mm, label 4: PE W V U, coding G: 0110
8TB4104.222L-10Terminal blocks — 4-pin push-in terminal block, 1-row, pitch: 10.16 mm, label 2: PE L3 L2 L1, coding L: 1010
8TB4103.222A-10Terminal blocks — 3-pin push-in terminal block, one-row, pitch: 10.16 mm, label 2: PE RB- RB+, coding A: 000
8TB3202.222C-40Terminal blocks — 2-pin push-in terminal block, 2-row, with locking mechanism, pitch: 7.62 mm, label 2: COM 24 V, coding C: 10
8TB3102.222C-20Terminal blocks — 2-pin push-in terminal block, 1-row, with locking mechanism, pitch: 7.62 mm, label 2: COM 24 V, coding C: 10
8TB2104.223L-00Terminal blocks — 4-pin push-in terminal block, 1-row, pitch: 5.08 mm, label 3: T- T+ B- B+, coding L: 1010
8TB2104.2210-00Terminal blocks — 4-pin push-in terminal block, 1-row, pitch: 5.08 mm, label 1: Numbered consecutively
8EZI044HSS.2302-0Terminal set — Terminal block set for ACOPOS P3 modules 8EI0*4**SS0.****-1: 1x 8TB2104.2210-00, 1x 8TB3202.222C-40, 1x 8TB4104.224G-10, 1x 8TB2104.223L-00…
8EZI044HSS.2201-0Terminal set — Terminal block set for ACOPOS P3 modules 8EI024H*SS, 8EI034H*SS, 8EI044H*SS: 1x 8TB2104.2210-00, 1x 8TB3102.222C-20, 1x 8TB4104.224G-10, 1x…

8EI034HCSS0.XXXX-1: frequently asked questions

When can 8EI034HCSS0.XXXX-1 be shipped?

8EI034HCSS0.XXXX-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8EI034HCSS0.XXXX-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8EI034HCSS0.XXXX-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8EI034HCSS0.XXXX-1, subject to availability and destination.

More B&R parts

B&R 8EI024HCSS0.XXXX-1 – ACOPOS P3 servo drive, 3x 200-480 VAC, 24 A, SafeMOTION
B&R
8EI024HCSS0.XXXX-1

ACOPOS P3 servo drive, 3x 200-480 VAC, 24 A, SafeMOTION

B&R 8EI024HWS10.XXXX-1 – ACOPOS P3 servo drive, 1 digital multi-standard encoder…
B&R
8EI024HWS10.XXXX-1

ACOPOS P3 servo drive, 1 digital multi-standard encoder…

B&R 8EI024HWSS0.XXXX-1 – ACOPOS P3 servo drive, 3x 200-480 VAC, 24 A, SafeMOTION
B&R
8EI024HWSS0.XXXX-1

ACOPOS P3 servo drive, 3x 200-480 VAC, 24 A, SafeMOTION

B&R 8EI034HCS10.XXXX-1 – ACOPOS P3 servo drive, 1 digital multi-standard encoder…
B&R
8EI034HCS10.XXXX-1

ACOPOS P3 servo drive, 1 digital multi-standard encoder…

B&R 8EI034HWS10.XXXX-1 – ACOPOS P3 servo drive, 1 digital multi-standard encoder…
B&R
8EI034HWS10.XXXX-1

ACOPOS P3 servo drive, 1 digital multi-standard encoder…

B&R 8EI034HWSS0.XXXX-1 – ACOPOS P3 servo drive, 3x 200-480 VAC, 34 A, SafeMOTION
B&R
8EI034HWSS0.XXXX-1

ACOPOS P3 servo drive, 3x 200-480 VAC, 34 A, SafeMOTION

B&R 8EI044HCS10.XXXX-1 – ACOPOS P3 servo drive, 1 digital multi-standard encoder…
B&R
8EI044HCS10.XXXX-1

ACOPOS P3 servo drive, 1 digital multi-standard encoder…

B&R 8EI034HCSS0.XXXX-1Price and lead time confirmed within 1 business day
Request a Quote