B&R 8B0F0160H000.000-1

Wide mains input voltage range

MPN
8B0F0160H000.000-1
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

What happens next
  1. We check stock, condition and lead time
  2. You get a written quote by email
  3. Approve it and we ship — in-stock parts within 1 business day
  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via
  • 100% positive eBay feedback

Have spare B&R parts? We buy surplus →

What is the B&R 8B0F0160H000.000-1?

Wide mains input voltage range

Optimized for ACOPOSmulti 8B0P power supply modules and ACOPOS P3

Compliance with limit values per CISPR11, group 2, class A

In order to conform to the EMC limit values, all 8BVI inverter modules in the drive system connected to the 8B0F line filter must be operated at the nominal switching frequency (5 kHz). The total length of all motor cables on each drive system (and for each 8B0F line filter) is not permitted to exceed 250 m. The cable length between the 8B0F line filter and the 8B0P power supply module is not permitted to exceed 5 m. The maximum permissible motor cable length per motor connection must also be taken into account (see 8BVI inverter modules).

Specifications

General information

Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)Not applicable
Certifications – ULUL E225616; Power conversion equipment
Certifications – ULcULus E225616; Power conversion equipment
Cooling and mounting typeWall mounting

Mains connection

Reduction of continuous current depending on ambient temperature – Starting at 50°C0.164 A/K
Reduction of continuous current depending on installation elevation – Starting at 2000 m above sea level15 A up to 3000 m; 14.2 A up to 4000 m
Variant – On mainsNo
Variant – On deviceNo
Variant – L1, L2, L3 and L1´, L2´, L3´Terminals
Variant – PEM5 threaded bolt
Terminal connection cross section – With wire end sleeve0.25 to 6 mm²
Terminal connection cross section – UL/C-UL-US28 to 8 AWG
Terminal connection cross section – CSA28 to 8 AWG
Permissible network configurationsTT, TNDelta/Wye with grounded wye neutral" in the USA."> (note: TT and TN power systems are commonly referred to as)
Mains input voltageMax. 3x 528 VAC
FrequencyMax. 60 Hz
Continuous current16 A eff (note: Valid under the following conditions: 3x 528 VAC mains input voltage, 50°C ambient temperature, cos phi = 0.8. The exact value depends on the application.)
Peak current24 A eff (<1 min), 1x/h
Power dissipation6.1 W (note: Valid under the following conditions: 25°C ambient temperature, frequency 50 Hz.)
Line filter per EN 61800-3, category C3Yes (note: Limit values from EN 61800-3 C3 (second environment).)

Electrical properties

Discharge capacitance0.4 µF (note: To simplify the design, the converted capacity on the DC bus is specified here.)
Leakage current33 mA

Operating conditions

Permissible mounting orientations – Hanging verticallyYes
Permissible mounting orientations – Horizontal, face upYes
Permissible mounting orientations – Standing horizontallyYes
Installation elevation above sea level – Nominal0 to 2000 m
Installation elevation above sea level – Maximum4000 m (note: Continuous operation at an installation elevation of 2000 m to 4000 m above sea level is possible taking the specified reduction of continuous current into account. Requirements that go beyond this must be arranged with B&R.)
Pollution degree per EN 61800-5-1PD 3 per EN 61800-5-1 and IEC 60664-1
Overvoltage category per IEC 60950III
Overvoltage category per EN 61800-5-1III per EN 60664-1
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Nominal5 to 40°C
Temperature – Maximum55°C
Temperature – Storage-25 to 55°C
Temperature – Transport-25 to 70°C
Relative humidity – Operation5 to 85%
Relative humidity – Storage5 to 95%
Relative humidity – TransportMax. 95% at 40°C

Mechanical properties

Dimensions – Width45 mm
Dimensions – Height263.8 mm
Dimensions – Depth70 mm
Vibration and shock3M4 per IEC 60721-3-3
Weight0.85 kg

8B0F0160H000.000-1: frequently asked questions

When can 8B0F0160H000.000-1 be shipped?

8B0F0160H000.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8B0F0160H000.000-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8B0F0160H000.000-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8B0F0160H000.000-1, subject to availability and destination.

More B&R parts

B&R 8B0C0320HW00.000-1 – ACOPOSmulti auxiliary supply module, 32 A, AS, wall mounting
B&R
8B0C0320HW00.000-1

ACOPOSmulti auxiliary supply module, 32 A, AS, wall mounting

B&R 8B0C0320HW00.00A-1 – Input for connecting an external 24 VDC source (e.g. UPS)
B&R
8B0C0320HW00.00A-1

Input for connecting an external 24 VDC source (e.g. UPS)

B&R 8B0F0160H000.000-1Price and lead time confirmed within 1 business day
Request a Quote