What is the Siemens 6DL1134-6JD00-0HX1?
SIMATIC ET 200SP HA, ET 200SP, analog ex-i input module, Ex-AI 4xTC/2xRTD 2-/3-/4-wire, suitable for BaseUnit type X1, channel diagnostics, 16bit, +/-0.05%
Specifications
General information
| Product type designation | Ex-AI 4xTC/2xRTD 2-/3-/4-wire |
| Firmware version | V1.0 |
| Firmware version — FW update possible | Yes |
| usable BaseUnits | BU type X1 |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Isochronous mode | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | V16 |
| Engineering with — STEP 7 configurable/integrated from version | V5.6 SP2 |
| Engineering with — PCS 7 configurable/integrated from version | V9.1 |
| Engineering with — PCS neo can be configured/integrated from version | V3.1 |
| Engineering with — PROFINET from GSD version/GSD revision | GSDML V2.35 |
| Operating mode — MSI | Yes |
| Redundancy — Redundancy capability | No |
CiR - Configuration in RUN
| Reparameterization possible in RUN | Yes |
Input current
| Current consumption (rated value) | 33 mA |
| Current consumption, max. | 40 mA |
Power loss
| Power loss, typ. | 0.8 W |
Address area
| Address space per module — Address space per module, max. | 16 byte; + 1 byte for QI information |
| Address space per module — Inputs | 16 byte; + 1 byte for QI information |
Hardware configuration
| Automatic encoding — Mechanical coding element | Yes |
| Selection of BaseUnit for connection variants — 2-wire connection | BU type X1 |
| Selection of BaseUnit for connection variants — 3-wire connection | BU type X1 |
| Selection of BaseUnit for connection variants — 4-wire connection | BU type X1 |
Analog inputs
| Number of analog inputs — For voltage measurement | 4 |
| Number of analog inputs — For resistance/resistance thermometer measurement | 2 |
| Number of analog inputs — For thermocouple measurement | 4 |
| Constant measurement current for resistance-type transmitter, typ. | 0.5 mA |
| Technical unit for temperature measurement adjustable | Yes; °C/°F/K |
| Input ranges (rated values), voltages — 1 V to +1 V | Yes; 16 bit incl. sign |
| Input ranges (rated values), voltages — 1 V to +1 V — Input resistance (-1 V to +1 V) | 1 MΩ |
| Input ranges (rated values), voltages — 250 mV to +250 mV | Yes; 16 bit incl. sign |
| Input ranges (rated values), voltages — 250 mV to +250 mV — Input resistance (-250 mV to +250 mV) | 1 MΩ |
| Input ranges (rated values), voltages — 50 mV to +50 mV | Yes; 16 bit incl. sign |
| Input ranges (rated values), voltages — 50 mV to +50 mV — Input resistance (-50 mV to +50 mV) | 1 MΩ |
| Input ranges (rated values), voltages — 80 mV to +80 mV | Yes; 16 bit incl. sign |
| Input ranges (rated values), voltages — 80 mV to +80 mV — Input resistance (-80 mV to +80 mV) | 1 MΩ |
| Input ranges (rated values), thermocouples — type B | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — type B — Input resistance (Type B) | 1 MΩ |
| Input ranges (rated values), thermocouples — type C | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — type C — Input resistance (Type C) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type E | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type E — Input resistance (Type E) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type J | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type J — Input resistance (type J) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type K | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type K — Input resistance (Type K) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type L | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type L — Input resistance (Type L) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type N | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type N — Input resistance (Type N) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type R | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type R — Input resistance (Type R) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type S | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type S — Input resistance (Type S) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type T | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type T — Input resistance (Type T) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type U | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type U — Input resistance (Type U) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type TXK/TXK(L) to GOST | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type TXK/TXK(L) to GOST — Input resistance (Type TXK/TXK(L) to GOST) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Cu 10 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Cu 10 — Input resistance (Cu 10) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 100 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 100 — Input resistance (Ni 100) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 1000 — Input resistance (Ni 1000) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — LG-Ni 1000 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 120 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 120 — Input resistance (Ni 120) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 200 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 200 — Input resistance (Ni 200) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 500 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 500 — Input resistance (Ni 500) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Pt 100 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Pt 100 — Input resistance (Pt 100) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Pt 1000 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Pt 1000 — Input resistance (Pt 1000) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Pt 200 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Pt 200 — Input resistance (Pt 200) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Pt 500 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Pt 500 — Input resistance (Pt 500) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 150 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 150 ohms — Input resistance (0 to 150 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 300 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 300 ohms — Input resistance (0 to 300 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 600 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 600 ohms — Input resistance (0 to 600 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 3000 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 3000 ohms — Input resistance (0 to 3000 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 6000 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 6000 ohms — Input resistance (0 to 6000 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — PTC | Yes; 15 bit |
| Input ranges (rated values), resistors — PTC — Input resistance (PTC) | 1 MΩ |
| Thermocouple (TC) — Temperature compensation — Parameterizable | Yes |
| Thermocouple (TC) — Temperature compensation — internal comparison point | Yes; BU type X1 |
| Thermocouple (TC) — Temperature compensation — Reference channel of the group | Yes |
| Thermocouple (TC) — Temperature compensation — Number of reference channel groups | 4 |
| Thermocouple (TC) — Temperature compensation — fixed reference temperature | Yes |
| Cable length — shielded, max. | 200 m; Ex characteristic values must be observed; line resistance at RTD (simple) max. 25 ohm; loop resistance at TC max. 8 kOhm |
Analog value generation for the inputs
| Measurement principle | integrating (Sigma-Delta) |
| Integration and conversion time/resolution per channel — Resolution with overrange (bit including sign), max. | 16 bit |
| Integration and conversion time/resolution per channel — Integration time, parameterizable | Yes; Channel-by-channel, results from the selected interference frequency suppression |
| Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms) — additional processing time for wire-break check | 20 ms; In the ranges resistance thermometers, resistors and thermocouples |
| Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms) — additional power line wire-break check | 20 ms, for 3/4-wire transducer (resistance thermometer and resistor) |
| Integration and conversion time/resolution per channel — Interference voltage suppression for interference frequency f1 in Hz | 16.6 / 50 / 60 Hz, channel-by-channel |
| Integration and conversion time/resolution per channel — Conversion time (per channel) | 180 / 60 / 50 ms, results from the selected interference frequency suppression |
| Smoothing of measured values — Parameterizable | Yes; none, weak, medium, strong, channel-by-channel |
Errors/accuracies
| Linearity error (relative to input range), (+/-) | 0.01 %; ±0.1 % for resistance thermometers and resistance |
| Temperature error (relative to input range), (+/-) | 0.0009 %/K; ±0.005 % / K at thermocouple |
| Crosstalk between the inputs, min. | 50 dB |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.05 % |
| Operational error limit in overall temperature range — Voltage, relative to input range, (+/-) | 0.1 % |
| Operational error limit in overall temperature range — Resistance, relative to input range, (+/-) | 0.1 % |
| Basic error limit (operational limit at 25 °C) — Voltage, relative to input range, (+/-) | 0.05 % |
| Basic error limit (operational limit at 25 °C) — Resistance, relative to input range, (+/-) | 0.05 % |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Series mode interference (peak value of interference < rated value of input range), min. | 70 dB |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode voltage, max. | 60 V; Applicable for use in non-hazardous areas; no common mode voltage permissible in hazardous areas |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode interference, min. | 90 dB |
Interrupts/diagnostics/status information
| Diagnostics function | Yes |
| Alarms — Diagnostic alarm | Yes |
| Alarms — Limit value alarm | Yes; two upper and two lower limit values in each case |
| Diagnoses — Monitoring the supply voltage | Yes |
| Diagnoses — Wire break | Yes; channel by channel |
| Diagnoses — Overflow/Underflow | Yes; channel by channel |
| Diagnostics indication LED — MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED — Channel status display | Yes; green LED |
| Diagnostics indication LED — for channel diagnostics | Yes; red LED |
| Diagnostics indication LED — for module diagnostics | Yes; green/red DIAG LED |
Ex(i) characteristics
| maximum values for connecting terminals for gas group IIC — Uo (no-load voltage), max. | 5.9 V |
| maximum values for connecting terminals for gas group IIC — Io (short-circuit current), max. | 18 mA |
| maximum values for connecting terminals for gas group IIC — Po (power output), max. | 27 mW |
| maximum values for connecting terminals for gas group IIC — Co (permissible external capacity), max. | 43 µF |
| maximum values for connecting terminals for gas group IIC — Lo (permissible external inductivity), max. | 110 mH |
| maximum values for connecting terminals for gas group IIC — Um (voltage at non-intrinsically safe connecting terminals), max. | 60 V |
Potential separation
| Potential separation channels — between the channels | No |
| Potential separation channels — between the channels and backplane bus | Yes |
| Potential separation channels — between the channels and the power supply of the electronics | Yes; Electrical isolation between the channels and input voltage PME |
Isolation
| Isolation tested with | further information on insulation can be found in the "ET 200SP HA / ET 200SP modules for devices in hazardous areas” System Manual |
| insulation of the field circuits to local ground acc. to IEC/EN 60079-11 tested with | 707 V DC (type test) |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C |
| Ambient temperature during operation — horizontal installation, max. | 70 °C |
| Ambient temperature during operation — vertical installation, min. | -40 °C |
| Ambient temperature during operation — vertical installation, max. | 60 °C |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 2 000 m |
Dimensions
| Width | 20 mm |
| Height | 73 mm |
| Depth | 58 mm |
Weights
| Weight, approx. | 55 g |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6DL1134-6JD00-0HX1: frequently asked questions
When can 6DL1134-6JD00-0HX1 be shipped?
6DL1134-6JD00-0HX1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6DL1134-6JD00-0HX1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6DL1134-6JD00-0HX1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6DL1134-6JD00-0HX1, subject to availability and destination.