What is the Siemens 6DL1135-6TB00-0HX1?
SIMATIC ET 200SP HA, ET 200SP, analog Ex-i HART output module, Ex-AQ 2xI HART, suitable for BaseUnit type X1, channel diagnostics, 16-bit, +/-0.3%
Specifications
General information
| Product type designation | Ex-AQ 2xI HART |
| Firmware version | V1.0 |
| Firmware version — FW update possible | Yes |
| usable BaseUnits | BU type X1 |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Isochronous mode | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | V16 |
| Engineering with — STEP 7 configurable/integrated from version | V5.6 SP2 |
| Engineering with — PCS 7 configurable/integrated from version | V9.1 |
| Engineering with — PCS neo can be configured/integrated from version | V3.1 |
| Engineering with — PROFINET from GSD version/GSD revision | GSDML V2.35 |
| Operating mode — MSO | Yes |
| Redundancy — Redundancy capability | No |
CiR - Configuration in RUN
| Reparameterization possible in RUN | Yes |
| Calibration possible in RUN | No |
Input current
| Current consumption (rated value) | 65 mA |
| Current consumption, max. | 70 mA |
Power loss
| Power loss, typ. | 1.2 W |
Address area
| Address space per module — Address space per module, max. | 4 byte; + 0/1 byte for QI information |
| Address space per module — Address space per module with HART, max. | 24 byte; + 0/1 byte for QI information |
| Address space per module — Address space per module with MultiHART, max. | 11 byte; + 0/1 byte for QI information |
Hardware configuration
| Automatic encoding — Mechanical coding element | Yes |
Analog outputs
| Number of analog outputs | 2 |
| Cycle time (all channels), min. | 3 ms |
| Output ranges, current — 0 to 20 mA | Yes; 15 bit |
| Output ranges, current — 4 mA to 20 mA | Yes; 16 bit incl. sign |
| Connection of actuators — for current output two-wire connection | Yes |
| Load impedance (in rated range of output) — for current outputs, min. | 50 Ω |
| Load impedance (in rated range of output) — with current outputs, max. | 500 Ω |
| Load impedance (in rated range of output) — with current outputs, inductive load, max. | Ex characteristic values must be observed |
| Cable length — shielded, max. | 500 m; Ex characteristic values must be observed |
| Cable length — unshielded, max. | 300 m; Ex characteristic values must be observed |
Analog value generation for the outputs
| Settling time — for resistive load | 1 ms; 500 ohms |
Errors/accuracies
| Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) | 0.02 % |
| Linearity error (relative to output range), (+/-) | 0.01 % |
| Temperature error (relative to output range), (+/-) | 0.005 %/K |
| Crosstalk between the outputs, min. | -70 dB |
| Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) | 0.02 % |
| Operational error limit in overall temperature range — Current, relative to output range, (+/-) | 0.5 %; 0 ... 60 °C: 0.3% |
| Basic error limit (operational limit at 25 °C) — Current, relative to output range, (+/-) | 0.2 % |
Protocols
| HART protocol | Yes |
Interrupts/diagnostics/status information
| Diagnostics function | Yes |
| Substitute values connectable | Yes |
| Alarms — Diagnostic alarm | Yes |
| Diagnoses — Monitoring the supply voltage | Yes; module-wise |
| Diagnoses — Wire break | Yes; From output value > 240 µA |
| Diagnoses — short-circuit | Yes; < 20 ohms as of 1 mA output value |
| Diagnoses — Group error | Yes |
| Diagnoses — Overflow/Underflow | Yes; channel by channel |
| Diagnostics indication LED — MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED — Channel status display | Yes; green LED |
| Diagnostics indication LED — for channel diagnostics | Yes; red LED |
| Diagnostics indication LED — for module diagnostics | Yes; green/red DIAG LED |
Ex(i) characteristics
| maximum values for connecting terminals for gas group IIC — Uo (no-load voltage), max. | 22 V |
| maximum values for connecting terminals for gas group IIC — Io (short-circuit current), max. | 91 mA |
| maximum values for connecting terminals for gas group IIC — Po (power output), max. | 501 mW |
| maximum values for connecting terminals for gas group IIC — Co (permissible external capacity), max. | 151 nF |
| maximum values for connecting terminals for gas group IIC — Lo (permissible external inductivity), max. | 4.1 mH |
| maximum values for connecting terminals for gas group IIC — Ui (intrinsically safe input voltage), max. | 10 V |
| maximum values for connecting terminals for gas group IIC — Um (voltage at non-intrinsically safe connecting terminals), max. | 60 V |
Potential separation
| Potential separation channels — between the channels | No |
| Potential separation channels — between the channels and backplane bus | Yes |
| Potential separation channels — between the channels and the power supply of the electronics | Yes; Electrical isolation between the channels and input voltage PME |
Isolation
| Isolation tested with | further information on insulation can be found in the "ET 200SP HA / ET 200SP modules for devices in hazardous areas” System Manual |
| insulation of the field circuits to local ground acc. to IEC/EN 60079-11 tested with | 707 V DC (type test) |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C |
| Ambient temperature during operation — horizontal installation, max. | 70 °C |
| Ambient temperature during operation — vertical installation, min. | -40 °C |
| Ambient temperature during operation — vertical installation, max. | 60 °C |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 2 000 m |
Dimensions
| Width | 20 mm |
| Height | 73 mm |
| Depth | 58 mm |
Weights
| Weight, approx. | 55 g |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6DL1135-6TB00-0HX1: frequently asked questions
When can 6DL1135-6TB00-0HX1 be shipped?
6DL1135-6TB00-0HX1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6DL1135-6TB00-0HX1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6DL1135-6TB00-0HX1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6DL1135-6TB00-0HX1, subject to availability and destination.