What is the Siemens 6ES7155-5MU00-0CN0?

SIMATIC ET 200MP,multi-fieldbus interface module, IM 155-5 MF HF, EtherNet/IP and Modbus TCP, 2 flexible ports via plug-in SIMATIC BusAdapter (sold separately), max. 30 I/O modules, multi-hot- swap with active backplane (sold separately), IRT with 250 µs, shared device with 4 controllers (1440 bytes each), 256 bytes per I/O module, MRP, MRPD, S2 redundancy, PN security class 1, optional cable grip (sold separately) PN security class 1, optional cable grip (sold separately)

Specifications

General information

Product type designationIM 155-5 MF HF
HW functional statusfrom FS01
Firmware versionV5.3.1
Firmware version — FW update possibleYes
Vendor identification (VendorID)002AH
Device identifier (DeviceID)0312H
Manufacturer ID according to ODVA (VendorID)0x04E3
Device ID according to ODVA (Product code)0x0FA3
Product function — I&M dataYes; I&M0 to I&M4
Product function — Module swapping during operation (hot swapping)Yes; In combination with active backplane bus
Product function — Isochronous modeYes
Product function — IRTYes
Product function — Tool changerYes; Docking station
Product function — Local coupling, IO dataYes
Product function — Local coupling, IO data — Number of coupling modules6; 1x MSO local output + max. 5x MSO local input
Engineering with — STEP 7 configurable/integrated from versionuse GSD file
Engineering with — PROFINET from GSD version/GSD revisionGSDML V2.45

Configuration control

via datasetYes

CiR - Configuration in RUN

Reparameterization possible in RUNYes
reconfiguration possible in RUNYes; add IO device only

Supply voltage

Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Short-circuit protectionYes
Mains buffering — Mains/voltage failure stored energy time10 ms

Input current

Current consumption (rated value)0.16 A; at 24 V DC and without load
Current consumption, max.1.2 A
Inrush current, max.13 A
I²t0.1 A²·s

Power

Infeed power to the backplane bus16 W
Power consumption from the backplane bus3.4 W; in case of operation with separate system power supply to the left of IM

Power loss

Power loss, typ.4.3 W

Address area

Address space per module — Address space per module, max.256 byte; For input and output data respectively
Address space per station — Address space per station, max.1 440 byte; For input and output data respectively

Hardware configuration

Integrated power supplyYes; 16 W
System power supply can be plugged in to left of IMYes; only with design with U-connectors
Number of permissible power segments3; incl. interface module
Rack — Modules per rack, max.30; I/O modules
Submodules — Number of submodules per station, max.256; 9 per I/O module

Interfaces

Transmission procedure100BASE-TX
Number of PROFINET interfaces1; 2 ports (switch)

1. Interface

Interface types — RJ 45 (Ethernet)Yes; with BusAdapter
Interface types — Number of ports2; with BusAdapter
Interface types — integrated switchYes
Interface types — BusAdapter (PROFINET)Yes; BA 2x RJ45, BA 2x FC, BA 2x M12
Protocols — PROFINET IO DeviceYes
Protocols — Open IE communicationYes
Protocols — Media redundancyYes; PROFINET MRP client / HRP client
PROFINET IO Device — Services — IRTYes; 250 µs to 4 ms in 125 µs frame
PROFINET IO Device — Services — Dynamic Frame Packing (DFP)No
PROFINET IO Device — Services — PROFIenergyNo
PROFINET IO Device — Services — Prioritized startupNo
PROFINET IO Device — Services — Shared deviceYes
PROFINET IO Device — Services — Number of IO Controllers with shared device, max.4; for multi-fieldbus mixed operation: 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master

Interface types

RJ 45 (Ethernet) — Transmission procedurePROFINET with 100 Mbit/s full duplex (100BASE-TX)
RJ 45 (Ethernet) — 100 MbpsYes
RJ 45 (Ethernet) — AutonegotiationYes
RJ 45 (Ethernet) — AutocrossingYes

Protocols

Supports protocol for PROFINET IOYes
PROFIsafeYes
PROFIBUSNo
EtherNet/IPYes
Modbus TCPYes
Redundancy mode — PROFINET system redundancy (S2)Yes; NAP S2
Redundancy mode — PROFINET system redundancy (S2) — on S7-1500R/HYes
Redundancy mode — PROFINET system redundancy (S2) — on S7-400HYes; use GSD file
Redundancy mode — PROFINET system redundancy (R1)No
Redundancy mode — H-Sync forwardingYes
Redundancy mode — Media redundancy — MRPYes
Redundancy mode — Media redundancy — MRPDYes
EtherNet/IP — Services — CIP Implicit MessagingYes
EtherNet/IP — Services — CIP Explicit MessagingYes
EtherNet/IP — Services — CIP SafetyNo
EtherNet/IP — Services — Configuration control via Explicit MessagingNo
EtherNet/IP — Services — Shared deviceYes; for multi-fieldbus mixed operation: 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master
EtherNet/IP — Services — Number of scanners with shared device, max.2
EtherNet/IP — Updating times — Requested Packet Interval (RPI)2 ms
EtherNet/IP — Address area — Address space per module, max.256 byte; 246 byte outputs / 256 byte inputs
EtherNet/IP — Address area — ForwardOpen (Class1 & 32 bit Header)500 byte; (246 byte outputs / 500 byte inputs)
EtherNet/IP — Address area — LargeForwardOpen (Class3)4 002 byte
EtherNet/IP — Connections — Number of rack connections2
Modbus TCP — Services — read coils (code=1)Yes
Modbus TCP — Services — read discrete inputs (code=2)Yes
Modbus TCP — Services — Read Holding Registers (Code=3)Yes
Modbus TCP — Services — write single coil (code=5)Yes
Modbus TCP — Services — write multiple coils (code=15)Yes
Modbus TCP — Services — Write Multiple Registers (Code=16)Yes
Modbus TCP — Services — Parameter change by masterYes
Modbus TCP — Services — Modbus TCP Security ProtocolNo
Modbus TCP — Address space per station — Address space per station, max.500 byte; (246 byte outputs / 500 byte inputs)
Modbus TCP — Address space per station — Access-consistent address space250 byte; (246 byte outputs / 250 byte inputs)
Modbus TCP — Updating time — I/O request interval2 ms
Modbus TCP — Connections — number of connections per device9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info)
Open IE communication — TCP/IPYes
Open IE communication — UDPYes
Open IE communication — SNMPYes
Open IE communication — LLDPYes
Open IE communication — ARPYes
Open IE communication — IGMPYes
Open IE communication — MulticastYes
Open IE communication — BroadcastYes
Open IE communication — IPv4Yes
Open IE communication — IPv6No

Isochronous mode

EquidistanceYes
shortest clock pulse250 µs
max. cycle4 ms
Bus cycle time (TDP), min.250 µs
Jitter, max.1 µs

Interrupts/diagnostics/status information

Status indicatorYes
AlarmsYes
Diagnostics functionYes
Diagnostics indication LED — RUN LEDYes; green LED
Diagnostics indication LED — ERROR LEDYes; red LED
Diagnostics indication LED — MAINT LEDYes; Yellow LED
Diagnostics indication LED — NS LEDYes; green/red LED
Diagnostics indication LED — MS LEDYes; green/red LED
Diagnostics indication LED — IO LEDYes; red-green-yellow LED
Diagnostics indication LED — Connection display LINK TX/RXYes; 2x green LEDs on BusAdapter

Potential separation

between backplane bus and electronicsNo
between PROFINET and all other circuitsYes; 1500 V AC (type test)
between supply and all other circuitsNo

Permissible potential difference

between different circuitsSafety extra low voltage SELV

Isolation

Isolation tested with707 V DC (type test)

Standards, approvals, certificates

Siemens Eco Profile (SEP)Siemens EcoTech
Network loading class3
Ecological footprint — environmental product declarationYes
Ecological footprint — Global warming potential — global warming potential, (total) [CO2 eq]64.1 kg
Ecological footprint — Global warming potential — global warming potential, (during production) [CO2 eq]11.1 kg
Ecological footprint — Global warming potential — global warming potential, (during operation) [CO2 eq]53.6 kg
Ecological footprint — Global warming potential — global warming potential, (after end of life cycle) [CO2 eq]-0.669 kg

Security

PROFINET Security Class1
signed firmware updateYes
Secure BootYes
securely removing dataYes
data integrityYes

Ambient conditions

Ambient temperature during operation — horizontal installation, min.-30 °C
Ambient temperature during operation — horizontal installation, max.60 °C
Ambient temperature during operation — vertical installation, min.-30 °C
Ambient temperature during operation — vertical installation, max.40 °C
Altitude during operation relating to sea level — Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Absolute humidity — dew point, min.-60 °C; suitable for dry room applications

Connection method

ET-Connection — via BU/BA SendNo

Mechanics/material

Strain reliefYes; Optional

Dimensions

Width35 mm
Height147 mm
Depth129 mm

Weights

Weight, approx.260 g; without BusAdapter

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

6ES7155-5MU00-0CN0: frequently asked questions

When can 6ES7155-5MU00-0CN0 be shipped?

6ES7155-5MU00-0CN0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 6ES7155-5MU00-0CN0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 6ES7155-5MU00-0CN0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6ES7155-5MU00-0CN0, subject to availability and destination.

More Siemens parts

Siemens 6ES7148-7JH00-0BB0 – SIMATIC ET 200clean, CM 8x IO-Link + DIQ 4x 24 V DC, 8x M12, 4x port class A + 4x port class B
Siemens
6ES7148-7JH00-0BB0

SIMATIC ET 200clean, CM 8x IO-Link + DIQ 4x 24 V DC, 8x M12

Siemens 6ES7155-5AA01-0AB0 – SIMATIC ET 200MP. PROFINET IO-DEVICE INTERFACEMODULE IM 155-5 PN ST FOR ET 200MP ELEKTRONIKMODULES
Siemens
6ES7155-5AA01-0AB0

SIMATIC ET 200MP. PROFINET IO-DEVICE INTERFACEMODULE IM…

Siemens 6ES7155-5BA00-0AB0 – SIMATIC ET 200MP. PROFIBUS connection IM 155-5 DP ST for max. 12 S7-1500 modules including PROFIBUS…
Siemens
6ES7155-5BA00-0AB0

SIMATIC ET 200MP. PROFIBUS connection IM 155-5 DP ST for…

Siemens 6ES7155-6AU30-0CN0
Siemens
6ES7155-6AU30-0CN0

SIMATIC ET 200SP, PROFINET, 3-port interface module

Siemens 6ES7155-6AW02-0BN0 – SIMATIC ET 200SP, PROFINET interface module IM 155-6 PN ST without server module
Siemens
6ES7155-6AW02-0BN0

SIMATIC ET 200SP, PROFINET interface module IM 155-6 PN ST…

Siemens 6ES7155-6BA01-0CN0 – SIMATIC ET 200SP, bundle PROFIBUS IM, IM 155-6DP HF, max. 32 I/O modules and 16 ET 200AL modules
Siemens
6ES7155-6BA01-0CN0

SIMATIC ET 200SP, bundle PROFIBUS IM, IM 155-6DP HF

Siemens 6ES7157-1AA00-0AB0 – SIMATIC ET 200AL, PROFIBUS interface module IM 157-1 DP, degree of protection IP67
Siemens
6ES7157-1AA00-0AB0

SIMATIC ET 200AL, PROFIBUS interface module IM 157-1 DP

Siemens 6ES7155-5MU00-0CN0Price and lead time confirmed within 1 business day
Request a Quote