Siemens 6AG1134-6JD00-2CA1
SIPLUS ET 200SP AI 4xRTD/TC high feature based on 6ES7134-6JD00-0CA1 with conformal coating, -40…+60 °C
- MPN
- 6AG1134-6JD00-2CA1
- Category
- SIPLUS analog inputs
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Siemens 6AG1134-6JD00-2CA1?
SIPLUS ET 200SP AI 4xRTD/TC high feature based on 6ES7134-6JD00-0CA1 with conformal coating, -40…+60 °C, analog input module, suitable for BU type A0, A1, color code CC00, channel diagnostics, 16-bit, +/-0.1%, 2/3/4-wire
Specifications
General information
| Product type designation | AI 4xRTD/TC 2-/3-/4-wire HF |
| Firmware version — FW update possible | Yes |
| based on | 6ES7134-6JD00-0CA1 |
| usable BaseUnits | BU type A0, A1 |
| Color code for module-specific color-coded label | CC00 |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Isochronous mode | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Operating mode — Oversampling | No |
| Operating mode — MSI | No |
CiR - Configuration in RUN
| Reparameterization possible in RUN | Yes |
| Calibration possible in RUN | Yes |
Supply voltage
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
Input current
| Current consumption (rated value) | 30 mA |
| Current consumption, max. | 32 mA |
Power loss
| Power loss, typ. | 0.75 W |
Address area
| Address space per module — Address space per module, max. | 8 byte; + 1 byte for QI information |
Hardware configuration
| Automatic encoding — Mechanical coding element | Yes |
| Automatic encoding — Type of mechanical coding element | Type A |
Analog inputs
| Number of analog inputs | 4 |
| permissible input voltage for voltage input (destruction limit), max. | 30 V |
| Constant measurement current for resistance-type transmitter, typ. | 2 mA |
| Cycle time (all channels), min. | Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels); for line compensation in case of a three-wire connection, an additional cycle is necessary |
| Technical unit for temperature measurement adjustable | Yes; °C/°F/K |
| Input ranges (rated values), voltages — 1 V to +1 V | Yes; 16 bit incl. sign |
| Input ranges (rated values), voltages — 1 V to +1 V — Input resistance (-1 V to +1 V) | 1 MΩ |
| Input ranges (rated values), voltages — 250 mV to +250 mV | Yes; 16 bit incl. sign |
| Input ranges (rated values), voltages — 250 mV to +250 mV — Input resistance (-250 mV to +250 mV) | 1 MΩ |
| Input ranges (rated values), voltages — 50 mV to +50 mV | Yes; 16 bit incl. sign |
| Input ranges (rated values), voltages — 50 mV to +50 mV — Input resistance (-50 mV to +50 mV) | 1 MΩ |
| Input ranges (rated values), voltages — 80 mV to +80 mV | Yes; 16 bit incl. sign |
| Input ranges (rated values), voltages — 80 mV to +80 mV — Input resistance (-80 mV to +80 mV) | 1 MΩ |
| Input ranges (rated values), thermocouples — type B | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — type B — Input resistance (Type B) | 1 MΩ |
| Input ranges (rated values), thermocouples — type C | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — type C — Input resistance (Type C) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type E | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type E — Input resistance (Type E) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type J | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type J — Input resistance (type J) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type K | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type K — Input resistance (Type K) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type L | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type L — Input resistance (Type L) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type N | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type N — Input resistance (Type N) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type R | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type R — Input resistance (Type R) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type S | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type S — Input resistance (Type S) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type T | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type T — Input resistance (Type T) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type U | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type U — Input resistance (Type U) | 1 MΩ |
| Input ranges (rated values), thermocouples — Type TXK/TXK(L) to GOST | Yes; 16 bit incl. sign |
| Input ranges (rated values), thermocouples — Type TXK/TXK(L) to GOST — Input resistance (Type TXK/TXK(L) to GOST) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Cu 10 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Cu 10 — Input resistance (Cu 10) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 100 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 100 — Input resistance (Ni 100) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 1000 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 1000 — Input resistance (Ni 1000) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — LG-Ni 1000 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — LG-Ni 1000 — Input resistance (LG-Ni 1000) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 120 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 120 — Input resistance (Ni 120) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 200 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 200 — Input resistance (Ni 200) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Ni 500 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Ni 500 — Input resistance (Ni 500) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Pt 100 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Pt 100 — Input resistance (Pt 100) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Pt 1000 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Pt 1000 — Input resistance (Pt 1000) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Pt 200 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Pt 200 — Input resistance (Pt 200) | 1 MΩ |
| Input ranges (rated values), resistance thermometer — Pt 500 | Yes; 16 bit incl. sign |
| Input ranges (rated values), resistance thermometer — Pt 500 — Input resistance (Pt 500) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 150 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 150 ohms — Input resistance (0 to 150 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 300 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 300 ohms — Input resistance (0 to 300 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 600 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 600 ohms — Input resistance (0 to 600 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 3000 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 3000 ohms — Input resistance (0 to 3000 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — 0 to 6000 ohms | Yes; 15 bit |
| Input ranges (rated values), resistors — 0 to 6000 ohms — Input resistance (0 to 6000 ohms) | 1 MΩ |
| Input ranges (rated values), resistors — PTC | Yes; 15 bit |
| Input ranges (rated values), resistors — PTC — Input resistance (PTC) | 1 MΩ |
| Thermocouple (TC) — Temperature compensation — Parameterizable | Yes |
| Thermocouple (TC) — Temperature compensation — Reference channel of the module | Yes |
| Thermocouple (TC) — Temperature compensation — internal comparison point | Yes; with BaseUnit type A1 |
| Thermocouple (TC) — Temperature compensation — Reference channel of the group | Yes |
| Thermocouple (TC) — Temperature compensation — Number of reference channel groups | 4; Group 0 to 3 |
| Thermocouple (TC) — Temperature compensation — fixed reference temperature | Yes |
| Cable length — shielded, max. | 200 m; 50 m with thermocouples |
Analog value generation for the inputs
| Measurement principle | integrating (Sigma-Delta) |
| Integration and conversion time/resolution per channel — Resolution with overrange (bit including sign), max. | 16 bit |
| Integration and conversion time/resolution per channel — Integration time, parameterizable | Yes |
| Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms) — additional processing time for wire-break check | 2 ms; In the ranges resistance thermometers, resistors and thermocouples |
| Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms) — additional power line wire-break check | 2 ms; for 3/4 wire transducer (resistance thermometer and resistor) |
| Integration and conversion time/resolution per channel — Interference voltage suppression for interference frequency f1 in Hz | 16.6 / 50 / 60 Hz |
| Integration and conversion time/resolution per channel — Conversion time (per channel) | 180 / 60 / 50 / (67.5 / 22.5 / 18.75) ms |
| Smoothing of measured values — Number of smoothing levels | 4; None; 4/8/16 times |
| Smoothing of measured values — Parameterizable | Yes |
Encoder
| Connection of signal encoders — for voltage measurement | Yes |
| Connection of signal encoders — for resistance measurement with two-wire connection | Yes |
| Connection of signal encoders — for resistance measurement with three-wire connection | Yes |
| Connection of signal encoders — for resistance measurement with four-wire connection | Yes |
Errors/accuracies
| Linearity error (relative to input range), (+/-) | 0.01 % |
| Temperature error (relative to input range), (+/-) | 0.0009 %/K; ±0.005 % / K at thermocouple |
| Crosstalk between the inputs, min. | 50 dB |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.05 % |
| Operational error limit in overall temperature range — Voltage, relative to input range, (+/-) | 0.2 % |
| Operational error limit in overall temperature range — Resistance, relative to input range, (+/-) | 0.2 % |
| Basic error limit (operational limit at 25 °C) — Voltage, relative to input range, (+/-) | 0.05 % |
| Basic error limit (operational limit at 25 °C) — Resistance, relative to input range, (+/-) | 0.05 % |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Series mode interference (peak value of interference < rated value of input range), min. | 70 dB |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode voltage, max. | 10 V |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode interference, min. | 90 dB |
Interrupts/diagnostics/status information
| Diagnostics function | Yes |
| Alarms — Diagnostic alarm | Yes |
| Alarms — Limit value alarm | Yes; two upper and two lower limit values in each case |
| Diagnoses — Monitoring the supply voltage | Yes |
| Diagnoses — Wire break | Yes; channel by channel |
| Diagnoses — Group error | Yes |
| Diagnoses — Overflow/Underflow | Yes; channel by channel |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED — Channel status display | Yes; green LED |
| Diagnostics indication LED — for channel diagnostics | Yes; red LED |
| Diagnostics indication LED — for module diagnostics | Yes; green/red DIAG LED |
Potential separation
| Potential separation channels — between the channels | No |
| Potential separation channels — between the channels and backplane bus | Yes |
| Potential separation channels — between the channels and the power supply of the electronics | Yes |
Permissible potential difference
| between the inputs (UCM) | 10 V DC |
Isolation
| Isolation tested with | 707 V DC (type test) |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation — horizontal installation, max. | 60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or configured slots to the left and right of the module |
| Ambient temperature during operation — vertical installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation — vertical installation, max. | 50 °C; = Tmax |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 5 000 m |
| Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) |
| Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
| Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Resistance — Use in stationary industrial systems — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Use on ships/at sea — to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request |
| Resistance — Use on ships/at sea — to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use on ships/at sea — to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * |
| Resistance — Use on ships/at sea — Against mechanical environmental conditions acc. to EN 60721-3-6 | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Conformal coating — Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Conformal coating — Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
Dimensions
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
Weights
| Weight, approx. | 30 g |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6AG1134-6JD00-2CA1: frequently asked questions
When can 6AG1134-6JD00-2CA1 be shipped?
6AG1134-6JD00-2CA1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6AG1134-6JD00-2CA1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6AG1134-6JD00-2CA1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG1134-6JD00-2CA1, subject to availability and destination.
More Siemens parts