Siemens 6AG1134-6HB00-2CA1

SIPLUS ET 200SP AI 2xU/I 2/4-W HF based on 6ES7134-6HB00-0CA1 with conformal coating, -40…+60 °C

MPN
6AG1134-6HB00-2CA1
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 6AG1134-6HB00-2CA1?

SIPLUS ET 200SP AI 2xU/I 2/4-W HF based on 6ES7134-6HB00-0CA1 with conformal coating, -40…+60 °C, analog input module, suitable for BU type A0, A1, color code CC05, channel diagnostics, 16-bit, +/-0.1%

Specifications

General information

Product type designationAI 2xU/I 2-/4-wire HF
Firmware versionV1.0
Firmware version — FW update possibleYes
based on6ES7134-6HB00-0CA1
usable BaseUnitsBU type A0, A1
Color code for module-specific color-coded labelCC03
Product function — I&M dataYes; I&M0 to I&M3
Product function — Isochronous modeYes
Product function — Measuring range scalableNo
Engineering with — STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Operating mode — OversamplingNo
Operating mode — MSIYes

CiR - Configuration in RUN

Reparameterization possible in RUNYes
Calibration possible in RUNYes

Supply voltage

Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes

Input current

Current consumption (rated value)39 mA; without sensor supply

Encoder supply

24 V encoder supply — 24 VYes
24 V encoder supply — Short-circuit protectionYes
24 V encoder supply — Output current, max.20 mA; max. 50 mA per channel for a duration < 10 s (two-wire)
Additional 24 V encoder supply — Short-circuit protectionYes; channel by channel
Additional 24 V encoder supply — Output current, max.100 mA; max. 150 mA for a duration of < 10 s (four-wire)

Power loss

Power loss, typ.0.95 W; without sensor supply

Address area

Address space per module — Address space per module, max.4 byte; + 1 byte for QI information

Hardware configuration

Automatic encodingYes
Automatic encoding — Mechanical coding elementYes
Automatic encoding — Type of mechanical coding elementType A
Selection of BaseUnit for connection variants — 2-wire connectionBU type A0, A1
Selection of BaseUnit for connection variants — 4-wire connectionBU type A0, A1

Analog inputs

Number of analog inputs2; Differential inputs
Number of analog inputs — For current measurement2
Number of analog inputs — For voltage measurement2
permissible input voltage for voltage input (destruction limit), max.30 V
permissible input current for current input (destruction limit), max.50 mA
Analog input with oversamplingNo
Standardization of measured valuesYes
Input ranges (rated values), voltages — 0 to +10 VYes; 15 bit
Input ranges (rated values), voltages — 0 to +10 V — Input resistance (0 to 10 V)75 kΩ
Input ranges (rated values), voltages — 1 V to 5 VYes; 15 bit
Input ranges (rated values), voltages — 1 V to 5 V — Input resistance (1 V to 5 V)75 kΩ
Input ranges (rated values), voltages — 10 V to +10 VYes; 16 bit incl. sign
Input ranges (rated values), voltages — 10 V to +10 V — Input resistance (-10 V to +10 V)75 kΩ
Input ranges (rated values), voltages — 5 V to +5 VYes; 16 bit incl. sign
Input ranges (rated values), voltages — 5 V to +5 V — Input resistance (-5 V to +5 V)75 kΩ
Input ranges (rated values), currents — 0 to 20 mAYes; 15 bit
Input ranges (rated values), currents — 0 to 20 mA — Input resistance (0 to 20 mA)130 Ω
Input ranges (rated values), currents — 20 mA to +20 mAYes; 16 bit incl. sign
Input ranges (rated values), currents — 20 mA to +20 mA — Input resistance (-20 mA to +20 mA)130 Ω
Input ranges (rated values), currents — 4 mA to 20 mAYes; 15 bit
Input ranges (rated values), currents — 4 mA to 20 mA — Input resistance (4 mA to 20 mA)130 Ω
Cable length — shielded, max.1 000 m; 200 m for voltage measurement

Analog value generation for the inputs

Measurement principleSigma Delta
Integration and conversion time/resolution per channel — Resolution with overrange (bit including sign), max.16 bit
Integration and conversion time/resolution per channel — Integration time, parameterizableYes
Integration and conversion time/resolution per channel — Integration time (ms)67.5 / 22.5 / 18.75 / 10 / 5 / 2.5 / 1.25 / 0.625 ms
Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms)68.03 / 22.83 / 19.03 / 10.28 / 5.23 / 2.68 / 1.43 / 0.730 ms
Integration and conversion time/resolution per channel — Interference voltage suppression for interference frequency f1 in Hz16.6 / 50 / 60 / 300 / 600 / 1 200 / 2 400 / 4 800
Integration and conversion time/resolution per channel — Conversion time (per channel)68.2 / 23 / 19.2 / 10.45 / 5.40 / 2.85 / 1.6 / 0.9 ms
Integration and conversion time/resolution per channel — Basic execution time of the module (all channels released)1 ms
Smoothing of measured values — Number of smoothing levels6; none; 2-/4-/8-/16-/32-fold
Smoothing of measured values — ParameterizableYes

Encoder

Connection of signal encoders — for voltage measurementYes
Connection of signal encoders — for current measurement as 2-wire transducerYes
Connection of signal encoders — for current measurement as 2-wire transducer — Burden of 2-wire transmitter, max.650 Ω
Connection of signal encoders — for current measurement as 4-wire transducerYes

Errors/accuracies

Linearity error (relative to input range), (+/-)0.01 %
Temperature error (relative to input range), (+/-)0.003 %/K
Crosstalk between the inputs, min.-50 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.01 %
Operational error limit in overall temperature range — Voltage, relative to input range, (+/-)0.2 %
Operational error limit in overall temperature range — Current, relative to input range, (+/-)0.2 %
Basic error limit (operational limit at 25 °C) — Voltage, relative to input range, (+/-)0.05 %; 0.1 % at SFU 4.8 kHz
Basic error limit (operational limit at 25 °C) — Current, relative to input range, (+/-)0.05 %; 0.1 % at SFU 4.8 kHz
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode voltage, max.35 V
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode interference, min.90 dB

Isochronous mode

Filtering and processing time (TCI), min.800 µs
Bus cycle time (TDP), min.1 ms
Jitter, max.5 µs

Interrupts/diagnostics/status information

Diagnostics functionYes
Alarms — Diagnostic alarmYes
Alarms — Limit value alarmYes; two upper and two lower limit values in each case
Diagnoses — Monitoring the supply voltageYes
Diagnoses — Wire breakYes; Measuring range 4 to 20 mA only
Diagnoses — Short-circuitYes; channel-by-channel, at 1 to 5 V or for short-circuit in encoder supply
Diagnoses — Group errorYes
Diagnoses — Overflow/UnderflowYes
Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Diagnostics indication LED — Channel status displayYes; green LED
Diagnostics indication LED — for channel diagnosticsYes; red LED
Diagnostics indication LED — for module diagnosticsYes; green/red DIAG LED

Potential separation

Potential separation channels — between the channelsYes
Potential separation channels — between the channels and backplane busYes
Potential separation channels — between the channels and the power supply of the electronicsYes

Isolation

Isolation tested with707 V DC (type test)

Ambient conditions

Ambient temperature during operation — horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
Ambient temperature during operation — horizontal installation, max.60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or configured slots to the left and right of the module including derating of the encoder supply to max. 50 mA per channel
Ambient temperature during operation — vertical installation, min.-40 °C; = Tmin (incl. condensation/frost); start-up @ -30 °C
Ambient temperature during operation — vertical installation, max.50 °C; = Tmax
Altitude during operation relating to sea level — Installation altitude above sea level, max.5 000 m
Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Resistance — Use in stationary industrial systems — Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Resistance — Use on ships/at sea — to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
Resistance — Use on ships/at sea — to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Resistance — Use on ships/at sea — to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Resistance — Use on ships/at sea — Against mechanical environmental conditions acc. to EN 60721-3-6Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Conformal coating — Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Conformal coating — Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A

Dimensions

Width15 mm
Height73 mm
Depth58 mm

Weights

Weight, approx.32 g

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

6AG1134-6HB00-2CA1: frequently asked questions

When can 6AG1134-6HB00-2CA1 be shipped?

6AG1134-6HB00-2CA1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 6AG1134-6HB00-2CA1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 6AG1134-6HB00-2CA1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG1134-6HB00-2CA1, subject to availability and destination.

More Siemens parts

Siemens 6AG1131-6TF00-7CA0 – SIPLUS ET 200SP DI 8xNAMUR HF based on 6ES7131-6TF00-0CA0 with conformal coating, -40…+70 °C
Siemens
6AG1131-6TF00-7CA0

SIPLUS ET 200SP DI 8xNAMUR HF based on 6ES7131-6TF00-0CA0…

Siemens 6AG1132-6HD01-7BB1 – SIPLUS ET 200SP RQ 4x 120V DC..230VAC/5A ST based on 6ES7132-6HD01-0BB1 with conformal coating, -40…+70 °C
Siemens
6AG1132-6HD01-7BB1

SIPLUS ET 200SP RQ 4x 120V DC..230VAC/5A ST based on…

Siemens 6AG1134-6JD00-2CA1 – SIPLUS ET 200SP AI 4xRTD/TC high feature based on 6ES7134-6JD00-0CA1 with conformal coating, -40…+60 °C
Siemens
6AG1134-6JD00-2CA1

SIPLUS ET 200SP AI 4xRTD/TC high feature based on…

Siemens 6AG1134-6JD00-2DA1 – SIPLUS ET 200SP AI 4xTC HS based on 6ES7134-6JD00-0DA1 with conformal coating, -40…+60 °C
Siemens
6AG1134-6JD00-2DA1

SIPLUS ET 200SP AI 4xTC HS based on 6ES7134-6JD00-0DA1 with…

Siemens 6AG1137-6EA00-2BA0 – SIPLUS ET 200SP CM CAN based on 6ES7137-6EA00-0BA0 with conformal coating, -40…+60 °C
Siemens
6AG1137-6EA00-2BA0

SIPLUS ET 200SP CM CAN based on 6ES7137-6EA00-0BA0 with…

Siemens 6AG1134-6HB00-2CA1Price and lead time confirmed within 1 business day