Siemens 6AG1137-6EA00-2BA0
SIPLUS ET 200SP CM CAN based on 6ES7137-6EA00-0BA0 with conformal coating, -40…+60 °C
- MPN
- 6AG1137-6EA00-2BA0
- Category
- SIPLUS CM CAN
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Siemens 6AG1137-6EA00-2BA0?
SIPLUS ET 200SP CM CAN based on 6ES7137-6EA00-0BA0 with conformal coating, -40…+60 °C, gateway to CAN Bus or CANopen networks, CAN 2.0A/B, CANopen Manager to CiA301/302, CANopen Slave to CiA301/302, IP20
Specifications
General information
| Product type designation | CM 1x CAN ST |
| Firmware version — FW update possible | Yes |
| based on | 6ES7137-6EA00-0BA0 |
| usable BaseUnits | BU type A0 |
| Color code for module-specific color-coded label | CC00 |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Module swapping during operation (hot swapping) | Yes |
| Product function — Isochronous mode | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
Supply voltage
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
Input current
| Current consumption, typ. | 20 mA |
| Current consumption, max. | 25 mA |
Power loss
| Power loss, typ. | 0.5 W |
Address area
| Address space per module — Address space per module, max. | 256 byte |
1. Interface
| Interface type | CAN according to CiA 303-1 |
| Isolated | Yes; 500 V AC or 707 V DC |
| Interface types — Number of ports | 1 |
| Interface types — Design of the connection | Push-in terminal |
| CAN — CAN operating modes | CAN Standard CAN 2.0A/B; CANopen Manager / Slave acc. to CiA |
| CAN — Specification acc. to CiA | CiA 301 & CiA 302 |
| CAN — Transmission rate, min. | 10 kbit/s |
| CAN — Transmission rate, max. | 1 000 kbit/s |
| CAN — max. number of devices | 60 |
| CAN — Number of SDOs in parallel | 16; Parallel |
| CAN — Number of PDOs | 128; Send / receive |
| CAN — Services — Node/life-guarding | Yes |
| CAN — Services — Heartbeat | Yes |
| CAN — Services — SYNC | Yes |
Interrupts/diagnostics/status information
| Alarms | Yes |
| Diagnostics function | Yes |
| Diagnostics indication LED — RUN LED | Yes |
| Diagnostics indication LED — ERROR LED | Yes |
| Diagnostics indication LED — MAINT LED | No |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Potential separation
| between backplane bus and interface | Yes |
Isolation
| Isolation tested with | 707 V DC (type test) |
Standards, approvals, certificates
| Ecological footprint — environmental product declaration | Yes |
| Ecological footprint — Global warming potential — global warming potential, (total) [CO2 eq] | 25.2 kg |
| Ecological footprint — Global warming potential — global warming potential, (during production) [CO2 eq] | 6.15 kg |
| Ecological footprint — Global warming potential — global warming potential, (during operation) [CO2 eq] | 19.4 kg |
| Ecological footprint — Global warming potential — global warming potential, (after end of life cycle) [CO2 eq] | -0.289 kg |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation — horizontal installation, max. | 60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or configured slots to the left and right of the module |
| Ambient temperature during operation — vertical installation, min. | -40 °C; = Tmin |
| Ambient temperature during operation — vertical installation, max. | 50 °C; = Tmax |
| Ambient temperature during operation — ceiling installation, min. | -40 °C; = Tmin |
| Ambient temperature during operation — ceiling installation, max. | 50 °C; = Tmax |
| Ambient temperature during operation — floor installation, min. | -40 °C; = Tmin |
| Ambient temperature during operation — floor installation, max. | 50 °C; = Tmax |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 5 000 m |
| Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) |
| Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
| Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Resistance — Use in stationary industrial systems — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Use on ships/at sea — to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) |
| Resistance — Use on ships/at sea — to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use on ships/at sea — to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * |
| Resistance — Use on ships/at sea — Against mechanical environmental conditions acc. to EN 60721-3-6 | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Conformal coating — Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Conformal coating — Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
Decentralized operation
| to SIMATIC S7-300 | No |
| to SIMATIC S7-400 | No |
| to SIMATIC S7-1200 | Yes |
| to SIMATIC S7-1500 | Yes |
Dimensions
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
Weights
| Weight, approx. | 32 g |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6AG1137-6EA00-2BA0: frequently asked questions
When can 6AG1137-6EA00-2BA0 be shipped?
6AG1137-6EA00-2BA0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6AG1137-6EA00-2BA0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6AG1137-6EA00-2BA0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG1137-6EA00-2BA0, subject to availability and destination.