Siemens 6AG1132-6FD00-7CU0
SIPLUS ET 200SP DQ 4x24..230VAC/2A HF based on 6ES7132-6FD00-0CU0 with conformal coating, -40…+70 °C
- MPN
- 6AG1132-6FD00-7CU0
- Category
- SIPLUS digital outputs
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Siemens 6AG1132-6FD00-7CU0?
SIPLUS ET 200SP DQ 4x24..230VAC/2A HF based on 6ES7132-6FD00-0CU0 with conformal coating, -40…+70 °C, digital output module, suitable for BU type U0, color code CC20, channel diagnostics two alternative operating modes: DQ and power control,
Specifications
General information
| Product type designation | DQ 4x24 ... 230 V AC/2 A HF |
| Firmware version — FW update possible | Yes |
| based on | 6ES7132-6FD00-0CU0 |
| usable BaseUnits | BU type U0 |
| Color code for module-specific color-coded label | CC20 |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Isochronous mode | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Operating mode — DQ | Yes |
| Operating mode — DQ with energy-saving function | Yes |
| Operating mode — PWM | No |
| Operating mode — Oversampling | No |
| Operating mode — MSO | No |
| Operating mode — Phase control | Yes; Control area: 8.5 ... 100% of the phase angle |
| Operating mode — Trailing-edge phase | No |
| Operating mode — Half-wave | Yes |
| Operating mode — Full-wave | Yes |
Supply voltage
| Rated value (AC) | 230 V; 47 ... 63 Hz, max. rate of change of frequency 1 mHz/s |
| permissible range, lower limit (AC) | 20.4 V |
| permissible range, upper limit (AC) | 264 V |
Input current
| Current consumption (rated value) | 8 mA; without load |
Output voltage
| Rated value (AC) | 230 V; 24V AC to 230V AC |
Power loss
| Power loss, typ. | 9 W; Active power, load voltage 230 V, all outputs loaded with 2 A, 50 Hz |
Address area
| Address space per module — Inputs | + 1 byte for QI information |
| Address space per module — Outputs | 8 byte |
Hardware configuration
| Automatic encoding | Yes |
| Automatic encoding — Mechanical coding element | Yes |
| Automatic encoding — Type of mechanical coding element | type C |
| Selection of BaseUnit for connection variants — 1-wire connection | BU type U0 |
| Selection of BaseUnit for connection variants — 2-wire connection | BU type U0 |
| Selection of BaseUnit for connection variants — 3-wire connection | BU type U0 + Potential distributor module |
Digital outputs
| Type of digital output | Triac |
| Number of digital outputs | 4 |
| Current-sinking | No |
| Current-sourcing | Yes |
| Digital outputs, parameterizable | Yes |
| Short-circuit protection | No; external fusing necessary |
| Open-circuit detection | Yes; channel by channel |
| Open-circuit detection — Response threshold, typ. | 1 mA; 40 V AC or more |
| Overload protection | No; A miniature fuse with 10 tripping current and tripping characteristic "quick response" must be provided in the module supply |
| Controlling a digital input | Yes |
| Switching capacity of the outputs — with resistive load, max. | 2 A; Max. 4 A, see additional description in manual |
| Switching capacity of the outputs — with inductive load, max. | 2 A |
| Switching capacity of the outputs — on lamp load, max. | 100 W; Tungsten rating in accordance with UL; for thermistors with higher power ratings, see the notes in the manual |
| Output voltage — for signal "1", min. | 20.4 V |
| Output current — for signal "1" rated value | 2 A |
| Output current — for signal "1" permissible range, min. | 10 mA |
| Output current — for signal "1" permissible range, max. | 4 A; note derating data in the manual |
| Output current — for signal "0" residual current, max. | 3 mA |
| Output delay with resistive load — "0" to "1", max. | 40 ms; 2 AC cycles |
| Output delay with resistive load — "1" to "0", max. | 20 ms; 1 AC cycle |
| Parallel switching of two outputs — for logic links | No |
| Parallel switching of two outputs — for uprating | No |
| Parallel switching of two outputs — for redundant control of a load | Yes |
| Switching frequency — with resistive load, max. | 10 Hz; Applies to DQ mode; limited by line frequency in PC mode |
| Switching frequency — with inductive load (acc. to IEC 60947-5-1, AC15), max. | 10 Hz; Applies to DQ mode; limited by line frequency in PC mode |
| Switching frequency — on lamp load, max. | 1 Hz; Applies to DQ mode; limited by line frequency in PC mode |
| Total current of the outputs — Current per channel, max. | 2 A; Max. 4 A, see additional description in manual |
| Total current of the outputs — Current per module, max. | 8 A |
| Total current of the outputs (per module) — horizontal installation — up to 40 °C, max. | 8 A; Applicable for current channels up to 2 A. For current channels between 2 A and 4 A, note derating data in the manual |
| Total current of the outputs (per module) — horizontal installation — up to 50 °C, max. | 6 A; Applicable for current channels up to 2 A. For current channels between 2 A and 4 A, note derating data in the manual |
| Total current of the outputs (per module) — horizontal installation — up to 60 °C, max. | 4 A; Applicable for current channels up to 2 A. For current channels between 2 A and 4 A, note derating data in the manual |
| Total current of the outputs (per module) — horizontal installation — up to 70 °C, max. | 2 A; Applicable for current channels up to 2 A |
| Total current of the outputs (per module) — vertical installation — up to 30 °C, max. | 8 A |
| Total current of the outputs (per module) — vertical installation — up to 40 °C, max. | 6 A |
| Total current of the outputs (per module) — vertical installation — up to 50 °C, max. | 4 A |
| Cable length — shielded, max. | 1 000 m |
| Cable length — unshielded, max. | 600 m |
Interrupts/diagnostics/status information
| Diagnostics function | Yes |
| Substitute values connectable | Yes |
| Alarms — Diagnostic alarm | Yes |
| Diagnoses — Diagnostic information readable | Yes |
| Diagnoses — Monitoring the supply voltage | Yes |
| Diagnoses — Wire break | Yes; channel by channel |
| Diagnoses — Short-circuit | No |
| Diagnoses — Group error | Yes |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED — Channel status display | Yes; green LED |
| Diagnostics indication LED — for channel diagnostics | Yes; red Fn LED |
| Diagnostics indication LED — for module diagnostics | Yes; green/red DIAG LED |
Potential separation
| Potential separation channels — between the channels | No |
| Potential separation channels — between the channels and backplane bus | Yes |
| Potential separation channels — between the channels and the power supply of the electronics | No |
Isolation
| Isolation tested with | 2 545 V DC/2 s (routine test) |
Standards, approvals, certificates
| Suitable for safety functions | No |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation — horizontal installation, max. | 70 °C; = Tmax |
| Ambient temperature during operation — vertical installation, min. | -40 °C; = Tmin |
| Ambient temperature during operation — vertical installation, max. | 50 °C; = Tmax |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 2 000 m |
| Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
| Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
| Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Resistance — Use in stationary industrial systems — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Use on ships/at sea — to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) |
| Resistance — Use on ships/at sea — to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use on ships/at sea — to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * |
| Resistance — Use on ships/at sea — Against mechanical environmental conditions acc. to EN 60721-3-6 | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Conformal coating — Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Conformal coating — Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
Dimensions
| Width | 20 mm |
| Height | 73 mm |
| Depth | 58 mm |
Weights
| Weight, approx. | 50 g |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6AG1132-6FD00-7CU0: frequently asked questions
When can 6AG1132-6FD00-7CU0 be shipped?
6AG1132-6FD00-7CU0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6AG1132-6FD00-7CU0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6AG1132-6FD00-7CU0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG1132-6FD00-7CU0, subject to availability and destination.
More Siemens parts