What is the B&R 5ACCIF01.FPLS-001?

1x POWERLINK interface managing or controlled node

1x RS232 interface

512 kB nvSRAM

Compatible with APC2x00 / PPC2x00

Interface option 5ACCIF01.FPLS-001 is equipped with a POWERLINK and RS232 interface. In addition, 512 kB nvSRAM is installed.

Specifications

General information

Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccULus HazLoc E180196; Industrial control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T4 (note: Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.)
Certifications – DNVTemperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: A (0.7 g); EMC: B (bridge and open deck) (note: Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV certificate for the product family.)
Certifications – CCSYes
Certifications – LRENV3
Certifications – KRYes
Certifications – ABSYes
Certifications – BVEC31B ; Temperature: 5 - 55°C; Vibration: 0.7 g; EMC: Bridge and open deck
LEDsL2, L3
B&R ID code0xE9B9

Controller

nvSRAM – Size512 kB
nvSRAM – Data retention20 years
nvSRAM – Read/Write enduranceMin. 1,000,000
nvSRAM – Remanent variables in power failure mode256 kB (for e.g. Automation Runtime, see Automation Help)

Interfaces

COM – Quantity1
COM – TypeRS232, modem supported, not galvanically isolated
COM – Execution10-pin, male
COM – UART16550-compatible, 16-byte FIFO buffer
COM – Max. baud rate115 kbit/s
POWERLINK – Quantity1
POWERLINK – TypeType 4 (note: For additional information, see Automation Help ( Communication / POWERLINK / General information / Hardware - IF / LS ).)
POWERLINK – ExecutionRJ45, shielded
POWERLINK – Transfer rate100 Mbit/s
POWERLINK – Transfer100BASE-TX
POWERLINK – Line lengthMax. 100 m between two stations (segment length)

Electrical properties

Power consumption1.5 W

Operating conditions

Pollution degree per EN 61131-2Pollution degree 2

Ambient conditions

Temperature – Operation-20 to 55°C
Temperature – Storage-20 to 60°C
Temperature – Transport-20 to 60°C
Relative humidity – Operation5 to 90%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

Weight25 g

Accessories

Optional accessories (1)
0TB1210.3100Terminal blocks — Two-row 10-pin terminal block 0TB1210.3100 is used to connect to the button/switch interface of the Automation Panel 9xD and to the interfa…

5ACCIF01.FPLS-001: frequently asked questions

When can 5ACCIF01.FPLS-001 be shipped?

5ACCIF01.FPLS-001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 5ACCIF01.FPLS-001 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 5ACCIF01.FPLS-001 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 5ACCIF01.FPLS-001, subject to availability and destination.

More B&R parts

B&R 5ACCIF01.FPCC-000 – 1x POWERLINK interface managing or controlled node2x CAN…
B&R
5ACCIF01.FPCC-000

1x POWERLINK interface managing or controlled node2x CAN…

B&R 5ACCIF01.FPCS-000 – Interface card, 1x RS485 interface, 1x CAN interface
B&R
5ACCIF01.FPCS-000

Interface card, 1x RS485 interface, 1x CAN interface

B&R 5ACCIF01.FPLK-000 – 1x POWERLINK interface for real-time communication
B&R
5ACCIF01.FPLK-000

1x POWERLINK interface for real-time communication

B&R 5ACCIF01.FPLS-000 – 1x POWERLINK interface managing or controlled node1x RS232…
B&R
5ACCIF01.FPLS-000

1x POWERLINK interface managing or controlled node1x RS232…

B&R 5ACCIF01.FPSC-000 – 1x POWERLINK interface managing or controlled node1x CAN…
B&R
5ACCIF01.FPSC-000

1x POWERLINK interface managing or controlled node1x CAN…

B&R 5ACCIF01.FPSC-001 – 1x POWERLINK interface managing or controlled node1x CAN…
B&R
5ACCIF01.FPSC-001

1x POWERLINK interface managing or controlled node1x CAN…

B&R 5ACCIF01.FPLS-001Price and lead time confirmed within 1 business day
Request a Quote