Siemens 6AG1155-6AU00-7HM0
SIPLUS ET 200SP IM155-6PN R1 based on 6ES7155-6AU00-0HM0 with conformal coating -40...+70 °C . 2-port…
- MPN
- 6AG1155-6AU00-7HM0
- Category
- SIPLUS interface modules
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Siemens 6AG1155-6AU00-7HM0?
SIPLUS ET 200SP IM155-6PN R1 based on 6ES7155-6AU00-0HM0 with conformal coating -40...+70 °C . 2-port interface module IM 155-6 PN R1, 1 slot for BusAdapter, max. 64 I/O modules R1 redundancy, multi hot swap, 0.25 ms, optional PN strain relief,
Specifications
General information
| Product type designation | IM 155-6 PN R1 |
| Firmware version | V6.1 |
| Firmware version — FW update possible | Yes |
| based on | 6ES7155-6AU00-0HM0 |
| Product function — I&M data | Yes; I&M0 to I&M4 |
| Product function — Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| Product function — Isochronous mode | No |
| Product function — IRT | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | V19 |
| Engineering with — STEP 7 configurable/integrated from version | use GSD file |
| Engineering with — PROFINET from GSD version/GSD revision | GSDML V2.45 |
Configuration control
| via dataset | No |
Supply voltage
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| Short-circuit protection | Yes |
| Mains buffering — Mains/voltage failure stored energy time | 10 ms |
Input current
| Current consumption, max. | 700 mA |
| Inrush current, max. | 5 A |
| I²t | 0.36 A²·s |
Power loss
| Power loss, typ. | 2.4 W |
Address area
| Address space per module — Address space per module, max. | 288 byte |
| Address space per station — Address space per station, max. | 1 440 byte |
Hardware configuration
| Rack — Quantity of operable ET 200SP modules, max. | 64 |
| Rack — Quantity of operable ET 200AL modules, max. | 0 |
| Submodules — Number of submodules per station, max. | 256 |
Interfaces
| Transmission procedure | 100BASE-TX |
| Number of PROFINET interfaces | 1; 2 ports (switch) |
1. Interface
| Interface types — RJ 45 (Ethernet) | Yes; with BusAdapter |
| Interface types — Number of ports | 2; with BusAdapter |
| Interface types — integrated switch | Yes |
| Interface types — BusAdapter (PROFINET) | Yes |
| Protocols — PROFINET IO device | Yes |
| Protocols — Open IE communication | Yes |
| Protocols — Media redundancy | Yes; PROFINET MRP client |
| PROFINET IO Device — Services — IRT | No |
| PROFINET IO Device — Services — Dynamic Frame Packing (DFP) | No |
| PROFINET IO Device — Services — PROFIenergy | No |
| PROFINET IO Device — Services — Prioritized startup | No |
| PROFINET IO Device — Services — Shared device | No |
Interface types
| RJ 45 (Ethernet) — Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
| RJ 45 (Ethernet) — 100 Mbps | Yes |
| RJ 45 (Ethernet) — Autonegotiation | Yes |
| RJ 45 (Ethernet) — Autocrossing | Yes |
Protocols
| PROFINET IO | Yes |
| PROFIsafe | Yes |
| PROFIBUS | No |
| EtherNet/IP | No |
| Modbus TCP | No |
| Redundancy mode — PROFINET system redundancy (S2) | No |
| Redundancy mode — PROFINET system redundancy (R1) | Yes |
| Redundancy mode — H-Sync forwarding | Yes |
| Redundancy mode — Media redundancy — MRP | Yes |
| Redundancy mode — Media redundancy — MRPD | No |
| Open IE communication — TCP/IP | Yes |
| Open IE communication — SNMP | Yes |
| Open IE communication — LLDP | Yes |
Interrupts/diagnostics/status information
| Status indicator | Yes |
| Alarms | Yes |
| Diagnostics function | Yes |
| Diagnostics indication LED — RUN LED | Yes; green LED |
| Diagnostics indication LED — ERROR LED | Yes; red LED |
| Diagnostics indication LED — MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED — ACT LED | Yes; green LED |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED — Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter |
Potential separation
| between backplane bus and electronics | No |
| between PROFINET and all other circuits | Yes; 1500 V AC (type test) |
| between supply and all other circuits | Yes |
Permissible potential difference
| between different circuits | Safety extra low voltage SELV |
Isolation
| Isolation tested with | 707 V DC (type test) |
Standards, approvals, certificates
| Network loading class | 3 |
| Ecological footprint — environmental product declaration | Yes |
| Ecological footprint — Global warming potential — global warming potential, (total) [CO2 eq] | 105 kg |
| Ecological footprint — Global warming potential — global warming potential, (during production) [CO2 eq] | 13.7 kg |
| Ecological footprint — Global warming potential — global warming potential, (during operation) [CO2 eq] | 91.9 kg |
| Ecological footprint — Global warming potential — global warming potential, (after end of life cycle) [CO2 eq] | -0.617 kg |
Security
| PROFINET Security Class | 1 |
| signed firmware update | Yes |
| Secure Boot | No |
| safely removing data | No |
| data integrity | Yes |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation — horizontal installation, max. | 70 °C; = Tmax |
| Ambient temperature during operation — vertical installation, min. | -40 °C; = Tmin |
| Ambient temperature during operation — vertical installation, max. | 50 °C; = Tmax |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 5 000 m |
| Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m) |
| Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
| Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Resistance — Use on ships/at sea — to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna) |
| Resistance — Use on ships/at sea — to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use on ships/at sea — to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * |
| Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Conformal coating — Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Conformal coating — Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
Connection method
| ET-Connection — via BU/BA Send | No |
Dimensions
| Width | 50 mm |
| Height | 138 mm |
| Depth | 89 mm |
Weights
| Weight, approx. | 192 g; without BusAdapter |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6AG1155-6AU00-7HM0: frequently asked questions
When can 6AG1155-6AU00-7HM0 be shipped?
6AG1155-6AU00-7HM0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6AG1155-6AU00-7HM0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6AG1155-6AU00-7HM0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG1155-6AU00-7HM0, subject to availability and destination.
More Siemens parts