What is the Mitsubishi Electric R60TCRT4BW?

The Mitsubishi Electric R60TCRT4BW is a temperature control in the MELSEC iQ-R Series. 4 channels, platinum RTD (Pt100, JPt100), heater disconnection detection, sampling cycle: 250 ms/4 cannels, 500 ms/4 channels, 18-point terminal block x 2, channel isolated, heating-cooling control. Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesMELSEC iQ-R Series
CategoryTemperature control
TypeRTD input
SubtypeWith heater disconnection detection
Outline4 channels, platinum RTD (Pt100, JPt100), heater disconnection detection, sampling cycle: 250 ms/4 cannels, 500 ms/4 channels, 18-point terminal block x 2, channel isolated, heating-cooling control

Specifications

Control outputTransistor output
Number of temperature input points4 channels/module
Applicable resistance temperature detectorPt100, JPt100
Accuracy: Indication accuracy: Ambient temperature: 25±5 ˚CFull scale × (±0.3 %)
Accuracy: Indication accuracy: Ambient temperature: 0...55 ˚CFull scale × (±0.7 %)
Sampling cycle250 ms/4 channels, 500 ms/4 channels
Control output cycle0.5...100 s
Input impedance1 MΩ
Input filter0...100 s (0: Input filter OFF)
Sensor correction value settingWhen the R mode is used: (-(full scale of input range)) to full scale of input range When the Q compatible mode function is used: -50.00...50.00 %
Operation at sensor input disconnectionUp-scale processing
Temperature control methodPID ON/OFF pulse or two-position control
PID constants range: PID constants settingCan be set by auto tuning.
PID constants range: Proportional band (P)When the R mode is used: 0(0.0) to full scale of input range (depending on the decimal point position) (0: Two-position control) When the Q compatible mode function is used: 0.0...1000.0 % (0: Two-position control)
PID constants range: Integral time (I)0...3600 s (set 0 for P control and PD control)
PID constants range: Derivative time (D)0...3600 s (set 0 for P control and PI control)
Set value (SV) setting rangeWithin the temperature range set by the platinum resistance thermometer to be used.
Dead band setting rangeWhen the R mode is used: 0(0.0) to full scale of input range (depending on the decimal point position) When the Q compatible mode function is used: 0.1...10.0 %
Transistor output: Output signalON/OFF pulse
Transistor output: Rated load voltage10...30 V DC
Transistor output: Maximum load current0.1 A/point, 0.4 A/common
Transistor output: Maximum inrush current0.4 A, 10 ms
Transistor output: Leakage current at OFF0.1 mA or less
Transistor output: Maximum voltage drop at ON1.0 V DC (TYP.) 0.1 A, 2.5 V DC (MAX.) 0.1 A
Transistor output: Response time: OFF to ON2 ms or less
Transistor output: Response time: ON to OFF2 ms or less
Isolation methodBetween input terminals and programmable controller power supply, between input channels: Transformer
Dielectric withstand voltageBetween input terminals and programmable controller power supply, between input channels: 500 V AC for 1 minute
Insulation resistanceBetween input terminals and programmable controller power supply, between input channels: 500 V DC, 20 MΩ or higher
Heater disconnection detection specifications: Current sensorU.R.D. Co., LTD. ・ CTL-12-S36-10 (0.0...100.0 A) ・ CTL-12-S56-10 (0.0...100.0 A) ・ CTL-6-P-H (0.00...20.00 A) ・ CTL-6-S-H (0.00...20.00 A) ・ CTL-12L-8 (0.00...100.00 A)
Heater disconnection detection specifications: Input accuracyFull scale × (±1.0 %)
Heater disconnection detection specifications: Number of alert delay3...255
External interface18-point terminal block (M3 screw) × 2
Number of occupied I/O points32 points, 2 slots (I/O assignment: Empty 16 points + Intelligent 16 points)
Internal current consumption (5 V DC)0.31 A
External dimensions: Height106 mm (base unit mounting side: 98 mm)
External dimensions: Width56 mm
External dimensions: Depth131 mm
Weight0.35 kg

Specifications

General specificationsRefer to the general specifications of the CPU module or remote head module.

R60TCRT4BW: frequently asked questions

When can R60TCRT4BW be shipped?

R60TCRT4BW is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up R60TCRT4BW in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for R60TCRT4BW and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for R60TCRT4BW, subject to availability and destination.

More Mitsubishi Electric (Factory Automation) parts

Mitsubishi Electric R60DAV8 – Mitsubishi MELSEC iQ-R Series Analog output
Mitsubishi Electric
R60DAV8

Mitsubishi MELSEC iQ-R Series Analog output

Mitsubishi Electric R60RD8-G – Mitsubishi MELSEC iQ-R Series Temperature input
Mitsubishi Electric
R60RD8-G

Mitsubishi MELSEC iQ-R Series Temperature input

Mitsubishi Electric R60TCRT4 – Mitsubishi MELSEC iQ-R Series Temperature control
Mitsubishi Electric
R60TCRT4

Mitsubishi MELSEC iQ-R Series Temperature control

Mitsubishi Electric R60TCRT4-TS – Mitsubishi MELSEC iQ-R Series Temperature control
Mitsubishi Electric
R60TCRT4-TS

Mitsubishi MELSEC iQ-R Series Temperature control

Mitsubishi Electric R60TCTRT2TT2 – Mitsubishi MELSEC iQ-R Series Temperature control
Mitsubishi Electric
R60TCTRT2TT2

Mitsubishi MELSEC iQ-R Series Temperature control

Mitsubishi Electric R60TCTRT2TT2-TS – Mitsubishi MELSEC iQ-R Series Temperature control
Mitsubishi Electric
R60TCTRT2TT2-TS

Mitsubishi MELSEC iQ-R Series Temperature control

Mitsubishi Electric R60TCTRT2TT2BW – Mitsubishi MELSEC iQ-R Series Temperature control
Mitsubishi Electric
R60TCTRT2TT2BW

Mitsubishi MELSEC iQ-R Series Temperature control

Mitsubishi Electric R60TD8-G – Mitsubishi MELSEC iQ-R Series Temperature input
Mitsubishi Electric
R60TD8-G

Mitsubishi MELSEC iQ-R Series Temperature input

Mitsubishi Electric R60TCRT4BWPrice and lead time confirmed within 1 business day
Request a Quote