R60RD8-G Mitsubishi MELSEC iQ-R Series Temperature input
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi MELSEC iQ-R Series – Analog |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can R60RD8-G be shipped?
R60RD8-G is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up R60RD8-G in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for R60RD8-G and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for R60RD8-G, subject to availability and destination.
The Mitsubishi Electric R60RD8-G is a temperature input in the MELSEC iQ-R Series. 8 channels, RTD (Pt100, JPt100, Ni100, Pt50), conversion speed: 10 ms/channel, 40-pin connector, channel isolated. Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | MELSEC iQ-R Series |
| Category | Temperature input |
| Type | RTD input |
| Subtype | Channel isolated |
| Outline | 8 channels, RTD (Pt100, JPt100, Ni100, Pt50), conversion speed: 10 ms/channel, 40-pin connector, channel isolated |
Specifications
| Number of analog input points | 8 points (8 channels) |
| Digital output: Temperature measured value | 16-bit signed binary value (-2000...8500) |
| Digital output: Scaling value | 16-bit signed binary value |
| Applicable resistance temperature detector | Pt100, JPt100, Ni100, Pt50 |
| Measured temperature range: Pt100 | -200...850 ˚C |
| Measured temperature range: JPt100 | -180...600 ˚C |
| Measured temperature range: Pt50 | -200...650 ˚C |
| Measured temperature range: Ni100 | -60...250 ˚C |
| Temperature detecting output current | 1.0 mA or less |
| Resolution | 0.1 ˚C |
| Accuracy | Accuracy (゚C) = (Conversion accuracy) + (Allowable difference of resistance temperature detector used) |
| Conversion accuracy: Pt100: -200...850 ゚C | ±0.8 ˚C (ambient temperature: 25±5 ゚C), ±2.4 ˚C (ambient temperature: 0...55 ゚C) |
| Conversion accuracy: Pt100: -20...120 ゚C | ±0.3 ˚C (ambient temperature: 25±5 ゚C), ±1.1 ˚C (ambient temperature: 0...55 ゚C) |
| Conversion accuracy: Pt100: 0...200 ゚C | ±0.4 ˚C (ambient temperature: 25±5 ゚C), ±1.2 ˚C (ambient temperature: 0...55 ゚C) |
| Conversion accuracy: JPt100: -180...600 ゚C | ±0.8 ˚C (ambient temperature: 25±5 ゚C), ±2.4 ˚C (ambient temperature: 0...55 ゚C) |
| Conversion accuracy: JPt100: -20...120 ゚C | ±0.3 ˚C (ambient temperature: 25±5 ゚C), ±1.1 ˚C (ambient temperature: 0...55 ゚C) |
| Conversion accuracy: JPt100: 0...200 ゚C | ±0.4 ˚C (ambient temperature: 25±5 ゚C), ±1.2 ˚C (ambient temperature: 0...55 ゚C) |
| Conversion accuracy: Pt50: -200...650 ゚C | ±0.8 ˚C (ambient temperature: 25±5 ゚C), ±2.4 ˚C (ambient temperature: 0...55 ゚C) |
| Conversion accuracy: Ni100: -60...250 ゚C | ±0.4 ˚C (ambient temperature: 25±5 ゚C), ±1.2 ˚C (ambient temperature: 0...55 ゚C) |
| Conversion speed | 10 ms/channel |
| Disconnection detection | Available |
| Isolation method | Between RTD input and programmable controller power supply, between RTD input channels: Transformer |
| Dielectric withstand voltage | Between RTD input channels and programmable controller power supply: 500 V AC rms for 1 minute Between RTD input channels: 1000 V AC rms for 1 minute |
| Insulation resistance | Between RTD input channels and programmable controller power supply, between RTD input channels: 500 V DC, 10 MΩ or higher |
| External interface | 40-pin connector |
| External interface: Applicable connector | A6CON1, A6CON2, A6CON4 (sold separately) |
| Number of occupied I/O points | 16 points (I/O assignment: Intelligent 16 points) |
| Internal current consumption (5 V DC) | 0.35 A |
| External dimensions: Height | 106 mm |
| External dimensions: Width | 27.8 mm |
| External dimensions: Depth | 110 mm |
| Weight | 0.19 kg |
Specifications
| General specifications | Refer to the general specifications of the CPU module or remote head module. |
Downloads & documentation
Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.
Data sheets & manuals
More Mitsubishi Electric (Factory Automation) parts
Available on requestR60DA8-G Mitsubishi MELSEC iQ-R Series Analog output
Available on requestR60DAH4 Mitsubishi MELSEC iQ-R Series Analog output
Available on requestR60DAI8 Mitsubishi MELSEC iQ-R Series Analog output
Available on requestR60DAV8 Mitsubishi MELSEC iQ-R Series Analog output
Available on requestR60TCRT4 Mitsubishi MELSEC iQ-R Series Temperature control
Available on requestR60TCRT4-TS Mitsubishi MELSEC iQ-R Series Temperature control
Available on requestR60TCRT4BW Mitsubishi MELSEC iQ-R Series Temperature control
Available on requestR60TCTRT2TT2 Mitsubishi MELSEC iQ-R Series Temperature control