EMU4-LM Mitsubishi Energy measuring EcoMonitorLight EcoMonitorPlus
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi Energy measuring – Energy Measuring Unit |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can EMU4-LM be shipped?
EMU4-LM is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up EMU4-LM in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for EMU4-LM and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for EMU4-LM, subject to availability and destination.
The Mitsubishi Electric EMU4-LM is a ecoMonitorLight EcoMonitorPlus in the Energy measuring. Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | Energy measuring |
| Category | EcoMonitorLight EcoMonitorPlus |
| Type | Logging Unit |
Specifications
| Category | Energy Saving Supporting Devices |
| Group | Energy Measuring Unit |
| Model | EcoMonitorLight EcoMonitorPlus |
| Use | Logging Unit |
| Model name | EMU4-LM |
| Ratings | 6.4V DC (supplied from energy measuring unit) |
| Power interruption backup | Total power interruption backup time of the battery (EMU4-BT) is one year (ave. daily temp. of 35℃ or lower). It is recommended to replace the battery every three years. |
| Power interruption backup: Set value | Saved in non-volatile memory * Data will not be lost even if power outage occurs. |
| Power interruption backup: Logging data System log data | Saved in volatile memory * Data will be lost if power outage occurs when the battery voltage is low (BAT.LED is lit). |
| Power interruption backup: Timer operation | Timer operation continues by using the battery in the event of power outage. * Timer operation stops if the battery voltage is low (BAT.LED is lit) when power outage occurs. After power is recovered, timer operation starts from 2013/01/01 00:00:00. |
| Clock accuracy | 1 min/month |
| Output data storage media *1 | SD memory card (SD, SDHC) |
| Compatible model | Energy measuring unit (EcoMonitorLight) Model: EMU4-BD1-MB, EMU4-HD1-MB Energy measuring unit (EcoMonitorPlus) Model: EMU4-BM1-MB, EMU4-HM1-MB, EMU4-LG1-MB, EMU4-CNT-MB, EMU4-VA2, EMU4-A2, EMU4-AX4, EMU4-PX4 |
| Compatible standard | EMC: EN-61326-1: 2013 |
| Usage environment: Operating temperature | -5℃ to +55℃ (ave. daily temp. of +35℃ or lower) |
| Usage environment: Operating humidity | 30% to 85%RH (no condensation) |
| Usage environment: Storage temperature | -10℃ to +60℃ (ave. daily temp. of +35℃ or lower) |
| Usage environment: Altitude | 2,000m or lower |
| Weight | 0.1 kg (Wight of logging unit only) |
| External dimensions (unit: mm) | 25 (W) x 90 (H) x 60 (D) (excluding protruding parts) |
| Parts sold separately | SD memory card (EMU4-SD2GB, EMU4-SD16GB) *1*2 |
| Consumables sold separately | Battery (EMU4-BT) *2 |
| Logging Specification: Logging mode: Automatic update | Automatic overwrite/update |
| Logging Specification: Logging mode: Date/time designation | Automatic start/stop according to start time setting |
| Logging Specification: Logging data type: Detailed data | Measurement data is saved according to set "Detailed Data Logging Cycle" (1 sec, 1 min, 5 min, 10 min, 15 min, 30 min). * Output as a detailed data file |
| Logging Specification: Logging data type: 1-Hour data | Measurement data is saved in 1-hour cycles. * Output as 1-hour and 1-day data files. |
| Logging Specification: Number of logging elements: Detailed data | Detailed data logging cycle of 1 sec → Maximum of 4 elements Detailed data logging cycle of other than 1 sec → Maximum of 10 elements |
| Logging Specification: Number of logging elements: 1-Hour data | Maximum of 10 elements |
| Logging Specification: System log data | 3,600 records |
| Logging Specification: Logging data and system log data output format | CSV format (ASCII code) |
Downloads & documentation
Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.
Data sheets & manuals
More Mitsubishi Electric (Factory Automation) parts
Available on requestEMU4-HD1-MB Mitsubishi Energy measuring EcoMonitorLight
Available on requestEMU4-HD1A-MB Mitsubishi Energy measuring EcoMonitorLight
Available on requestEMU4-HM1-MB Mitsubishi Energy measuring EcoMonitorPlus
Available on requestEMU4-LG1-MB Mitsubishi Energy measuring EcoMonitorPlus
Available on requestEMU4-PX4 Mitsubishi Energy measuring EcoMonitorPlus
Available on requestEMU4-VA2 Mitsubishi Energy measuring EcoMonitorPlus
Available on requestET-N150 150A Mitsubishi Low-voltage switchgear Related Equipment
Available on requestET-N360 360A Mitsubishi Low-voltage switchgear Related Equipment