Siemens 6ES7132-8BH00-0AN0
SIMATIC ET 200BL, digital output module, DQ 16x24 V DC/0.5 A
- MPN
- 6ES7132-8BH00-0AN0
- Category
- CPU & Controllers
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Siemens 6ES7132-8BH00-0AN0?
SIMATIC ET 200BL, digital output module, DQ 16x24 V DC/0.5 A, output characteristic according to IEC 61131 source output (PNP,sourcing output) packing unit: 1 unit, color code CC00
Specifications
General information
| Product type designation | DQ 16x24VDC/0.5A |
| HW functional status | from FS01 |
| Firmware version — FW update possible | No |
| Color code for module-specific color-coded label | CC00 |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Isochronous mode | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | STEP 7 V18 or higher; MicroWin V3.0 or higher; Configuration in ES via GSDML; |
| Engineering with — PROFINET from GSD version/GSD revision | GSDML V2.45 |
| Operating mode — DQ | Yes |
| Operating mode — DQ with energy-saving function | No |
| Operating mode — PWM | No |
| Operating mode — Cam control (switching at comparison values) | No |
| Operating mode — Oversampling | No |
| Operating mode — MSO | No |
Supply voltage
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 20.4 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
| external protection for power supply lines | Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic |
Input current
| Current consumption (rated value) | 55 mA |
| Current consumption, max. | 8.1 A; with 8 A output to load |
Output voltage
| Rated value (DC) | 24 V |
Current carrying capacity
| For P1 and P2 bus, max. | 10 A |
Power loss
| Power loss, typ. | 1 W; rated voltage, 50 % load, 50 % active channels |
Address area
| Address space per module — Address space per module, max. | 2 byte |
| Address space per module — Outputs | 2 byte |
Hardware configuration
| Automatic encoding | No |
| Automatic encoding — Mechanical coding element | No |
| Formation of potential groups — support of potential groups | No |
Digital outputs
| Type of digital output | Source output (PNP, current-sourcing) |
| Number of digital outputs | 16 |
| Current-sinking | No |
| Current-sourcing | Yes |
| Digital outputs, parameterizable | Yes |
| output type acc. to IEC 61131, type 0.5 | Yes |
| Short-circuit protection | Yes; per channel, electronic |
| Short-circuit protection — Response threshold, typ. | 1.45 A; 0.7 to 1.7 A |
| Limitation of inductive shutdown voltage to | typ. (L+) -52 V |
| Controlling a digital input | Yes |
| Switching capacity of the outputs — with resistive load, max. | 0.5 A |
| Switching capacity of the outputs — on lamp load, max. | 5 W |
| Load resistance range — lower limit | 48 Ω |
| Load resistance range — upper limit | 100 kΩ |
| Output current — for signal "1" rated value | 0.5 A |
| Output current — for signal "1" permissible range, max. | 0.5 A |
| Output current — for signal "0" residual current, max. | 5 µA |
| Output delay with resistive load — "0" to "1", max. | 100 µs |
| Output delay with resistive load — "1" to "0", max. | 300 µs |
| Parallel switching of two outputs — for uprating | No |
| Switching frequency — with resistive load, max. | 100 Hz |
| Switching frequency — with inductive load, max. | 2 Hz |
| Switching frequency — on lamp load, max. | 10 Hz |
| Total current of the outputs — Current per channel, max. | 0.5 A |
| Total current of the outputs — Current per module, max. | 8 A |
| Cable length — shielded, max. | 1 000 m |
| Cable length — unshielded, max. | 600 m |
Interrupts/diagnostics/status information
| Diagnostics function | Yes |
| Substitute values connectable | Yes |
| Alarms — Diagnostic alarm | Yes |
| Diagnoses — Monitoring the supply voltage | Yes |
| Diagnoses — Wire break | No |
| Diagnoses — short-circuit | No |
| Diagnoses — Group error | No |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED — Channel status display | Yes; green LED |
| Diagnostics indication LED — for channel diagnostics | No |
| Diagnostics indication LED — for module diagnostics | Yes; green/red DIAG LED |
Potential separation
| between backplane bus and supply voltage | Yes |
| Potential separation digital outputs — between the channels | No |
| Potential separation digital outputs — between the channels and backplane bus | Yes |
| Potential separation digital outputs — between the channels and the power supply of the electronics | No |
Isolation
| Isolation tested with | 500 V AC/707 V DC, type test |
Standards, approvals, certificates
| Suitable for safety functions | No |
| Ecological footprint — environmental product declaration | Yes |
| Ecological footprint — Global warming potential — global warming potential, (total) [CO2 eq] | 28.7 kg |
| Ecological footprint — Global warming potential — global warming potential, (during production) [CO2 eq] | 4.87 kg |
| Ecological footprint — Global warming potential — global warming potential, (during operation) [CO2 eq] | 24.5 kg |
| Ecological footprint — Global warming potential — global warming potential, (after end of life cycle) [CO2 eq] | -0.623 kg |
| Use in hazardous areas — EAC Ex | No |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -30 °C |
| Ambient temperature during operation — horizontal installation, max. | 60 °C |
| Ambient temperature during operation — vertical installation, min. | -30 °C |
| Ambient temperature during operation — vertical installation, max. | 50 °C |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200BL system manual |
Connection method
| Terminals — Conductor cross-section, min. | 0.14 mm²; follow detailed information in System manual of ET 200BL |
| Terminals — Conductor cross-section, max. | 2.5 mm²; follow detailed information in System manual of ET 200BL |
| Terminals — Number of process terminals to I/O module | 16 |
| Terminals — Number of terminals with connection to P1 and P2 bus | 0 |
Dimensions
| Width | 15 mm |
| Height | 117 mm |
| Depth | 74 mm |
Weights
| Weight, approx. | 80 g |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6ES7132-8BH00-0AN0: frequently asked questions
When can 6ES7132-8BH00-0AN0 be shipped?
6ES7132-8BH00-0AN0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6ES7132-8BH00-0AN0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6ES7132-8BH00-0AN0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6ES7132-8BH00-0AN0, subject to availability and destination.