What is the Siemens 6DL1131-6TD00-0HX1?
SIMATIC ET 200SP HA, ET 200SP, digital ex-i input module, DI 4xNAMUR, suitable for BaseUnit type X1, channel diagnostics
Specifications
General information
| Product type designation | Ex-DI 4xNAMUR |
| Firmware version | V1.0 |
| Firmware version — FW update possible | Yes |
| usable BaseUnits | BU type X1 |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Isochronous mode | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | V16 |
| Engineering with — STEP 7 configurable/integrated from version | V5.6 SP2 |
| Engineering with — PCS 7 configurable/integrated from version | V9.1 |
| Engineering with — PCS neo can be configured/integrated from version | V3.1 |
| Engineering with — PROFINET from GSD version/GSD revision | GSDML V2.35 |
| Operating mode — DI | Yes |
| Operating mode — Counter | Yes |
| Operating mode — MSI | Yes |
| Redundancy — Redundancy capability | No |
Input current
| Current consumption (rated value) | 50 mA |
| Current consumption, max. | 55 mA |
Encoder supply
| Number of outputs | 4 |
| Output voltage (DC) | 8.2 V |
| Short-circuit protection | Yes |
Power loss
| Power loss, typ. | 1.2 W |
Address area
| Address space per module — Inputs | 10 byte; + 1 byte for QI information |
| Address space per module — Outputs | 10 byte |
Hardware configuration
| Automatic encoding — Mechanical coding element | Yes |
| Selection of BaseUnit for connection variants — 2-wire connection | BU type X1 |
Digital inputs
| Number of digital inputs | 4; NAMUR |
| Digital inputs, parameterizable | Yes |
| Pulse extension | Yes; 0.5 s, 1 s, 2 s |
| Time stamp | Yes; Resolution 10 ms |
| Time stamp (with precision of 1 ms) | No |
| Edge evaluation | Yes; Positive edge, negative edge |
| Signal change flutter | Yes; 2 to 32 signal changes |
| Flutter observation window | Yes; 0.5 s, 1 s to 100 s in 1-s steps |
| Digital input functions, parameterizable — Counter — Number, max. | 2; Channel 0 and 1 |
| Digital input functions, parameterizable — Counter — Counting frequency, max. | 5 kHz |
| Digital input functions, parameterizable — Counter — Counting direction up/down | Yes; Up |
| Input voltage — Rated value (DC) | 8.2 V |
| Input current — for 10 k switched contact — for signal "0", max. | 1.2 mA |
| Input current — for 10 k switched contact — for signal "1", min. | 2.1 mA |
| Input current — for unswitched contact — for signal "0", max. (permissible quiescent current) | 0.5 mA |
| Input current — for unswitched contact — for signal "1", typ. | 8 mA |
| Input current — for NAMUR encoders — for signal "0", min. | 0.35 mA |
| Input current — for NAMUR encoders — for signal "0", max. | 1.2 mA |
| Input current — for NAMUR encoders — for signal "1", min. | 2.1 mA |
| Input current — for NAMUR encoders — for signal "1", max. | 6.4 mA |
| Input delay (for rated value of input voltage) — for NAMUR inputs — at "0" to "1", max. | 12 ms |
| Input delay (for rated value of input voltage) — for NAMUR inputs — at "1" to "0", max. | 12 ms |
| Cable length — shielded, max. | 500 m; Ex characteristic values must be observed; without shield applied on both sides and cable lengths of more than 200 m, measured value distortions can occur when using the inputs as counter/ frequency meter |
| Cable length — unshielded, max. | 300 m; Ex characteristic values must be observed; without shield applied on both sides and cable lengths of more than 200 m, measured value distortions can occur when using the inputs as counter/ frequency meter |
Encoder
| Connectable encoders — NAMUR encoder/changeover contact according to EN 60947 | Yes |
| Connectable encoders — Single contact / changeover contact unconnected | Yes |
| Connectable encoders — Single contact / changeover contact connected with 10 kΩ | Yes |
Interrupts/diagnostics/status information
| Diagnostics function | Yes |
| Alarms — Diagnostic alarm | Yes |
| Alarms — Maintenance interrupt | Yes |
| Alarms — Hardware interrupt | Yes; channel by channel |
| Diagnoses — Diagnostic information readable | Yes |
| Diagnoses — Monitoring the supply voltage | Yes |
| Diagnoses — Monitoring the supply voltage — parameterizable | Yes |
| Diagnoses — Monitoring of encoder power supply | Yes |
| Diagnoses — Wire break | Yes; channel by channel |
| Diagnoses — Short-circuit | Yes; channel by channel |
| Diagnoses — Group error | Yes |
| Diagnostics indication LED — MAINT LED | Yes; Yellow LED |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED — Channel status display | Yes; green LED |
| Diagnostics indication LED — for channel diagnostics | Yes; red LED |
| Diagnostics indication LED — for module diagnostics | Yes; green/red DIAG LED |
Integrated Functions
| Measuring functions — Accuracy — Frequency measurement | 1 % |
Ex(i) characteristics
| maximum values for connecting terminals for gas group IIC — Uo (no-load voltage), max. | 9.6 V |
| maximum values for connecting terminals for gas group IIC — Io (short-circuit current), max. | 61 mA; applies for up to four circuits connected in parallel |
| maximum values for connecting terminals for gas group IIC — Po (power output), max. | 145 mW; applies for up to four circuits connected in parallel |
| maximum values for connecting terminals for gas group IIC — Co (permissible external capacity), max. | 3.6 µF; applies for up to four circuits connected in parallel |
| maximum values for connecting terminals for gas group IIC — Lo (permissible external inductivity), max. | 13 mH; applies for up to four circuits connected in parallel |
| maximum values for connecting terminals for gas group IIC — Um (voltage at non-intrinsically safe connecting terminals), max. | 60 V |
Potential separation
| Potential separation channels — between the channels | No |
| Potential separation channels — between the channels and backplane bus | Yes |
| Potential separation channels — between the channels and the power supply of the electronics | Yes; Electrical isolation between the channels and input voltage PME |
Isolation
| Isolation tested with | further information on insulation can be found in the "ET 200SP HA / ET 200SP modules for devices in hazardous areas” System Manual |
| insulation of the field circuits to local ground acc. to IEC/EN 60079-11 tested with | 707 V DC (type test) |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C |
| Ambient temperature during operation — horizontal installation, max. | 70 °C |
| Ambient temperature during operation — vertical installation, min. | -40 °C |
| Ambient temperature during operation — vertical installation, max. | 60 °C |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 2 000 m |
Dimensions
| Width | 20 mm |
| Height | 73 mm |
| Depth | 58 mm |
Weights
| Weight, approx. | 55 g |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6DL1131-6TD00-0HX1: frequently asked questions
When can 6DL1131-6TD00-0HX1 be shipped?
6DL1131-6TD00-0HX1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6DL1131-6TD00-0HX1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6DL1131-6TD00-0HX1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6DL1131-6TD00-0HX1, subject to availability and destination.
More Siemens parts