What is the Pepperl Fuchs KFD2-SRA-Ex4?
4-channel isolated barrier
24 V DC supply (Power Rail)
Dry contact or NAMUR inputs
50 % less wiring, 2:1 technology
Relay contact output
Line fault detection (LFD)
Reversible mode of operation
4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Housing width: 20 mm, Number of channels: 4-channel, 2:1 Method, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 4 x relay (NO contact), Reversible mode of operation
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 190176 |
| Signal type | Digital Input |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Supply
| Connection | Power Rail or terminals 14+, 15- |
| Rated voltage | 19 ... 30 V DC Ur |
| Ripple | ≤ 10 % |
| Rated current | 45 ... 70 mA Ir |
| Power dissipation | 1.2 W |
Input
| Connection side | field side |
| Connection | terminals 1-, 2+, 3-; 4-, 5+, 6- |
| Rated values | acc. to EN 60947-5-6 (NAMUR), see manual for electrical data |
| Open circuit voltage/short-circuit current | approx. 8 V DC / approx. 8 mA |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA |
| Pulse/Pause ratio | min. 35 ms / min. 35 ms (non-AC operation) min. 70 ms / min. 70 ms (AC operation) |
| Line fault detection | breakage I ≤ 0.15 mA , short-circuit I > 6 mA |
Output
| Connection side | control side |
| Connection | output I: terminals 7, 8 ; output II: terminals 8, 9 ; output III: terminals 10, 11 ; output IV: terminals 11, 12 |
| Output I ... IV | Signal I ... Signal IV ; relay |
| Contact loading | 253 V AC/2 A /cos φ > 0.7; 40 V DC/2 A resistive load; |
| Energized/De-energized delay | approx. 30 ms / approx. 30 ms |
| Mechanical life | 5 x 106 switching cycles |
| Collective error message | Power Rail |
Transfer characteristics
| Switching frequency | ≤ 10 Hz (non-AC operation) ≤ 3 Hz (AC operation) |
Galvanic isolation
| Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Input/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output/Output | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Low voltage: Directive 2014/35/EU | EN 61010-1:2010 |
Conformity
| Electromagnetic compatibility | NE 21:2006 |
| Degree of protection | IEC 60529:2001 |
| Input | EN 60947-5-6:2000 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 150 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Height | 119 mm |
| Width | 20 mm |
| Depth | 115 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | ZELM 99 ATEX 0009 |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Input | Ex ia IIC |
| Voltage | 10 V Uo |
| Current | 14 mA Io |
| Power | 35 mW (linear characteristic) Po |
| Supply: Maximum safe voltage | 40 V DC (Attention! Um is no rated voltage.) Um |
| Output: Contact loading | 230 V AC + 10 % / 2 A / 100 VA / cos φ ≥ 0.7; 40 V DC / 2 A resistive load |
| Fault indication output: Maximum safe voltage | 40 V DC Um |
| Galvanic isolation: Input/input | not available |
| Galvanic isolation: Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Galvanic isolation: Input/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000 |
International approvals
| UL approval: Control drawing | 116-0145 |
| IECEx approval: IECEx certificate | IECEx TUN 04.0003 |
| IECEx approval: IECEx marking | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (9)
- Taiwan OSHA (ML151200720676)
- China SITIIAS CCC Ex Certificate (2021322316003615 (Singapore))
- EU Declaration of Conformity (Pepperl+Fuchs)
- South Africa MASC (MASC MS/19-6054)
- DNV Marine (TAA00001WX)
- Canada USA UL Certificate of Compliance Hazardous Location UL E106378 cULus (CoC 20160608 - E106378 RepRef 19970520)
- Australia SIMTARS (ANZEx 13.2005)
- Europe ZELM ATEX Category (1) GD ATEX Category (M1) (ZELM 99 ATEX 0009)
- United Kingdom CML UK-Type Examination Certificate UKEX Category (1) D UKEX Category (1) G UKEX Category (M1) (CML 21UKEX2936)
KFD2-SRA-Ex4: frequently asked questions
When can KFD2-SRA-Ex4 be shipped?
KFD2-SRA-Ex4 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-SRA-Ex4 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-SRA-Ex4 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-SRA-Ex4, subject to availability and destination.
More Pepperl Fuchs parts