Pepperl Fuchs KFD2-ST3-Ex1.LB

Switch Amplifier

MPN
KFD2-ST3-Ex1.LB
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs KFD2-ST3-Ex1.LB?

1-channel isolated barrier

24 V DC supply (Power Rail)

Dry contact or NAMUR inputs

2 active transistor outputs

Usable as signal splitter (1 input and 2 outputs)

Reversible mode of operation

Line fault detection (LFD)

Up to SIL 2 (SC 3) acc. to IEC/EN 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection

Specifications

General specifications

Order code (Pepperl+Fuchs part number)262110
Signal typeDigital Input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3

Supply

ConnectionPower Rail or terminals 14+, 15-
Rated voltage19 ... 30 V DC Ur
Ripple≤ 10 %
Rated current15 ... 10 mA + Iout Ir
Power dissipation≤ 800 mW including maximum power dissipation in the output

Input

Connection sidefield side
Connectionterminals 1+, 2+, 3-
Rated valuesacc. to EN 60947-5-6 (NAMUR), see manual for electrical data
Open circuit voltage/short-circuit currentapprox. 10 V DC / approx. 8 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Pulse/Pause ratiomin. 100 µs / min. 100 µs

Output

Connection sidecontrol side
Connectionoutput I: terminal 7+ ; output II: terminal 9+
Rated voltage30 V DC Ur
Rated current100 mA Ir
Response time≤ 200 µs
Signal level1-signal: (supply voltage) - 3 V max. for 100 mA 0-signal: blocked output (off-state current ≤ 10 µA)
Output Isignal ; Transistor
Output IIsignal or fault message ; Transistor
Collective error messagePower Rail

Transfer characteristics

Switching frequency≤ 5 kHz

Galvanic isolation

Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2012 , EN 61326-3-2:2008
Degree of protectionIEC 60529:2001
InputEN 60947-5-6:2000

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Height119 mm
Width20 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateEXA 16 ATEX 0016 X
MarkingII 3(1)G Ex nA [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
InputEx ia
Voltage10.5 V Uo
Current17.1 mA Io
Power45 mW (linear characteristic) Po
Supply: Maximum safe voltage253 V AC (Attention! Um is no rated voltage.) Um
Output: Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.) Um
Galvanic isolation: Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic isolation: Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010

International approvals

UL approvalE106378
Control drawing116-0424 (cULus)
IECEx approval: IECEx certificateIECEx EXA 16.0009X
IECEx approval: IECEx markingEx nA [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFD2-ST3-Ex1.LB: frequently asked questions

When can KFD2-ST3-Ex1.LB be shipped?

KFD2-ST3-Ex1.LB is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD2-ST3-Ex1.LB in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD2-ST3-Ex1.LB and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-ST3-Ex1.LB, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFD2-SR2-Ex2.W.SM – Standstill and Rotational Direction Monitor
Pepperl Fuchs
KFD2-SR2-Ex2.W.SM

Standstill and Rotational Direction Monitor

Pepperl Fuchs KFD2-STC4-Ex1 – SMART Transmitter Power Supply
Pepperl Fuchs
KFD2-STC4-Ex1

SMART Transmitter Power Supply

Pepperl Fuchs KFD2-STC5-1 – SMART Transmitter Power Supply
Pepperl Fuchs
KFD2-STC5-1

SMART Transmitter Power Supply

Pepperl Fuchs KFD2-STC5-1.2O – SMART Transmitter Power Supply
Pepperl Fuchs
KFD2-STC5-1.2O

SMART Transmitter Power Supply

Pepperl Fuchs KFD2-ST3-Ex1.LBPrice and lead time confirmed within 1 business day
Request a Quote