What is the Pepperl Fuchs KCD2-STC-Ex1.ES.SP?

1-channel isolated barrier

24 V DC supply (Power Rail)

Input for 2-wire SMART transmitters and current sources

Output for 4 mA ... 20 mA or 1 V ... 5 V

Sink or source mode

Line fault detection (LFD)

Housing width 12.5 mm

Connection via spring terminals with push-in connection technology

Up to SIL 3 acc. to IEC/EN 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Sink or source mode, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC

Specifications

General specifications

Order code (Pepperl+Fuchs part number)322428
Signal typeAnalog input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 3
Systematic capability (SC)SC 3

Supply

ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC Ur
Ripple≤ 10 %
Rated current≤ 50 mA Ir
Power dissipation≤ 800 mW
Power consumption≤ 1.2 W

Input

Connection sidefield side
Connectionterminals 1+, 2-; 3+, 4-
Input signal4 ... 20 mA , limited to approx. 27 mA reverse polarity protected
Line fault detectiondownscaling ≤ 3 mA ; upscaling ≥ 22 mA
Voltage dropapprox. 5 V on terminals 3+, 4-
Available voltage≥ 15 V at 20 mA terminals 1+, 2-

Output

Connection sidecontrol side
Connectionterminals 5-, 6+
Load0 ... 300 Ω (source mode)
Output signalsource mode: 4 ... 20 mA or 1 ... 5 V (internal resistor: 250 Ω, 0.1 %) sink mode: 4 ... 20 mA, operating voltage 16 ... 28 V For additional internal or external loads the voltage drop has to be considered, e. g. 250 Ω x 20 mA = 5 V.
Ripple20 mV rms

Fault indication output

Output typefault bus signal , open collector transistor

Transfer characteristics

Deviationat 20 °C (68 °F) ≤ ± 20 µA incl. calibration, linearity, hysteresis, loads and supply voltage fluctuations (source mode and sink mode 4 ... 20 mA) ≤ 10 mV incl. calibration, linearity, hysteresis and fluctuations of supply voltage (source mode 1 ... 5 V)
Influence of ambient temperature< 0.5 mV/K (0 ... 70 °C (32 ... 158 °F)); < 1 mV/K (-20 ... 0 °C (-4 ... 32 °F)) (source mode 1 ... 5 V)
Frequency rangefield side into the control side: bandwidth with 1 mApp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)
Settling time≤ 200 ms
Rise time/fall time≤ 20 ms

Galvanic isolation

Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Output/power supplyBasic isolation acc. to EN 61010-1 rated insulation voltage ≤ 50 V

Indicators/settings

Display elementsLEDs
Control elementsDIP switch
Factory settingoutput: current source
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2017 For further information see system description.
Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-20 ... 70 °C (-4 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connectionspring terminals
Massapprox. 100 g
Dimensions12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Height124 mm
Width12.5 mm
Depth114 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateCESI 10 ATEX 071
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
InputEx ia
Supply: Maximum safe voltage253 V AC (Attention! Um is no rated voltage.) Um
Equipmentterminals 1+, 2-
Voltage25.2 V Uo
Current100 mA Io
Power630 mW Po
Internal capacitance5.7 nF Ci
Internal inductancenegligible Li
Equipmentterminals 3+, 4-
Voltage< 30 V Ui
Current< 128 mA Ii
Voltage7.2 V Uo
Current100 mA Io
Power25 mW Po
Internal capacitance5.7 nF Ci
Internal inductancenegligible Li
CertificateCESI 19 ATEX 005 X
MarkingII 3G Ex ec IIC T4 Gc
Directive conformity: Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-7:2015

International approvals

UL approvalE106378
Control drawing116-0378 (cULus)
IECEx approval: IECEx certificateIECEx CES 11.0001X
IECEx approval: IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KCD2-STC-Ex1.ES.SP: frequently asked questions

When can KCD2-STC-Ex1.ES.SP be shipped?

KCD2-STC-Ex1.ES.SP is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KCD2-STC-Ex1.ES.SP in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KCD2-STC-Ex1.ES.SP and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-STC-Ex1.ES.SP, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KCD2-STC-Ex1 – SMART Transmitter Power Supply
Pepperl Fuchs
KCD2-STC-Ex1

SMART Transmitter Power Supply

Pepperl Fuchs KCD2-UT2-1 – Universal Temperature Converter
Pepperl Fuchs
KCD2-UT2-1

Universal Temperature Converter

Pepperl Fuchs KCD2-UT2-Ex1 – Universal Temperature Converter
Pepperl Fuchs
KCD2-UT2-Ex1

Universal Temperature Converter

Pepperl Fuchs KCD2-STC-Ex1.ES.SPPrice and lead time confirmed within 1 business day
Request a Quote