Pepperl Fuchs KCD2-STC-Ex1
SMART Transmitter Power Supply
- MPN
- KCD2-STC-Ex1
- Category
- K-System (DIN Rail Mounting)
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs KCD2-STC-Ex1?
1-channel isolated barrier
24 V DC supply (Power Rail)
Input for 2-wire SMART transmitters and current sources
Output for 4 mA ... 20 mA or 1 V ... 5 V
Housing width 12.5 mm
Up to SIL 2 (SC 3) acc. to IEC/EN 61508
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: 2-wire transmitter, Field device [2]: current source, Signal: 0/4 ... 20 mA
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 70150439 |
| Signal type | Analog input |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | Power Rail or terminals 9+, 10- |
| Rated voltage | 19 ... 30 V DC Ur |
| Ripple | ≤ 10 % |
| Rated current | ≤ 45 mA at 24 V and 20 mA source mode output Ir |
| Power dissipation | ≤ 800 mW |
| Power consumption | ≤ 1.1 W |
Input
| Connection side | field side |
| Connection | terminals 1+, 2-; 3+, 4- |
| Input signal | 4 ... 20 mA limited to approx. 26 mA |
| Open circuit voltage/short-circuit current | terminals 1+, 2-: 22 V / 26 mA |
| Voltage drop | terminals 3+, 4- : approx. 5 V |
| Available voltage | terminals 1+, 2-: ≥ 15 V at 20 mA ; ≥ 18 V at 4 mA |
Output
| Connection side | control side |
| Connection | terminals 5-, 6+ terminals 5-, 8+ for HART resistor |
| Load | 0 ... 350 Ω (source mode) |
| Output signal | source mode: 4 ... 20 mA or 1 ... 5 V (internal resistor: 250 Ω, 0.1 %) sink mode: 4 ... 20 mA, operating voltage 10 ... 30 V For additional internal or external loads (e. g. terminal +8) the voltage drop has to be considered, e. g. 250 Ω x 20 mA = 5 V. |
| Ripple | 20 mV rms |
Transfer characteristics
| Deviation | at 20 °C (68 °F) ≤ ± 0.2 % incl. non-linearity and hysteresis (source mode 1 ... 5 V) |
| Influence of ambient temperature | < 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode and sink mode 4 ... 20mA) < 0.5 mV/K (-20 ... 70 °C (-4 ... 158 °F)); < 1 mV/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode 1...5 V) |
| Frequency range | field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) |
| Settling time | ≤ 50 ms |
| Rise time/fall time | ≤ 10 ms |
Galvanic isolation
| Input/Output | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Input/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LED |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 EN 61326-3-2:2018 |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | UL 61010-1:2019 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 100 g |
| Dimensions | 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | CESI 06 ATEX 021 X |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Input | Ex ia |
| Supply: Maximum safe voltage | 250 V AC (Attention! Um is no rated voltage.) Um |
| Equipment | terminals 1+, 2- |
| Voltage | 25.2 V Uo |
| Current | 100 mA Io |
| Power | 630 mW Po |
| Internal capacitance | 5.7 nF Ci |
| Internal inductance | negligible Li |
| Equipment | terminals 3+, 4- |
| Voltage | 30 V Ui |
| Current | 128 mA Ii |
| Power | 1000 mW Pi |
| Voltage | 7.2 V Uo |
| Current | 100 mA Io |
| Power | 25 mW Po |
| Internal capacitance | 5.7 nF Ci |
| Internal inductance | negligible Li |
| Certificate | CESI 19 ATEX 021 X |
| Marking | II 3G Ex ec IIC T4 Gc |
| Galvanic isolation: Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Galvanic isolation: Input/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN IEC 60079-7:2015+A1:2018 |
International approvals
| FM approval: FM certificate | FM 18 CA 0116 X , FM 19 US 0117 X |
| FM approval: Control drawing | 116-0469 (cFMus) |
| UL approval | E106378 |
| Control drawing | 116-0459 (cULus) |
| IECEx approval: IECEx certificate | IECEx CES 06.0001X |
| IECEx approval: IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (10)
- Australia SIMTARS Group I (ANZEx 08.2009X)
- EU Declaration of Conformity (Pepperl+Fuchs)
- SITIIAS CCC Ex Certificate (2024322316005880 (Vietnam))
- Korea KTL (Korea) (26-KA4BO-0203X (Singapore))
- EU Declaration of Conformity (Pepperl+Fuchs)
- Worldwide TUV Rheinland Functional Safety Certificate (968/FSP 1937.02/25)
- Korea KOSHA (25-AV4BO-0121X (Vietnam))
- South Africa MASC (MASC MS/18-0958X)
- DNV Marine (TAA00001WX)
- Brasil TUV Rheinland Brazil (TÜV 23.1083 X (Vietnam))
KCD2-STC-Ex1: frequently asked questions
When can KCD2-STC-Ex1 be shipped?
KCD2-STC-Ex1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KCD2-STC-Ex1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KCD2-STC-Ex1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-STC-Ex1, subject to availability and destination.