Available on request

Pepperl Fuchs KCD2-UT2-1

MPN: KCD2-UT2-1 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryK-System (DIN Rail Mounting, Highly Functional)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can KCD2-UT2-1 be shipped?

KCD2-UT2-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KCD2-UT2-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KCD2-UT2-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-UT2-1, subject to availability and destination.

Universal Temperature Converter. 1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple. Signal type: Analog input. Safety Integrity Level (SIL): SIL 2. Connection: terminals 9+, 10- or power feed module/Power Rail. Rated voltage: 19 ... 30 V DC. Ripple: within the supply tolerance. Power dissipation: ≤ 0.98 W. Power consumption: max. 0.98 W. Programming interface: programming socket. Connection side: field side. Connection: terminals 1, 2, 3, 4. RTD: type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)type Cu10, Cu50, Cu100 (P50353-92)type Ni100 (DIN 43760). Measuring currentapprox. 200 µA with RTDTypes of measuring2-, 3-, 4-wire connectionLead resistancemax. 50 Ω per lineMeasurement loop monitoringsensor breakage, sensor short-circuit: . Measuring current: approx. 200 µA with RTD. Types of measuring: 2-, 3-, 4-wire connection. Lead resistance: max. 50 Ω per line. Measurement loop monitoring: sensor breakage, sensor short-circuit. Thermocouples: type B, E, J, K, N, R, S, T (IEC 584-1: 1995)type L (DIN 43710: 1985)type TXK, TXKH, TXA (P8.585-2001). Cold junction compensationexternal and internalMeasurement loop monitoringsensor breakage: . Cold junction compensation: external and internal. Measurement loop monitoring: sensor breakage. Potentiometer: 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection). Voltage: selectable within the range -100 ... 100 mV. Input resistance: ≥ 1 MΩ (-100 ... 100 mV). Connection side: control side. Connection: terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+). Output: Analog current output. Current range0 ... 20 mA or 4 ... 20 mAFault signaldownscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)Sourceload 0 ... 550 Ω open-circuit voltage ≤ 18 VSinkVoltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.The maximum value of the resistance is (V - 5)/0.0215 Ω.: . Current range: 0 ... 20 mA or 4 ... 20 mA. Fault signal: downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43). Source: load 0 ... 550 Ω open-circuit voltage ≤ 18 V. Sink: Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.The maximum value of the resistance is (V - 5)/0.0215 Ω.. Deviation: . After calibrationPt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection)) thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1.5 K (1.7 K for types R and S)) , includes ± 1.3 K fault of the cold junction compensation (CJC) mV: ± (50 µV + 0.1 % of span)potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes faults due to lead resistance))Influence of ambient temperaturePt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compensation (CJC) includedmV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)potentiometer: ± 0.006 % of span/K ΔTamb*) *) ΔTamb = ambient temperature change referenced to 23 °C (296 K)Influence of supply voltage< 0.01 % of spanInfluence of load≤ 0.001 % of output value per 100 Ω: . After calibration: Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection)) thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1.5 K (1.7 K for types R and S)) , includes ± 1.3 K fault of the cold junction compensation (CJC) mV: ± (50 µV + 0.1 % of span)potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes faults due to lead resistance)). Influence of ambient temperature: Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compensation (CJC) includedmV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)potentiometer: ± 0.006 % of span/K ΔTamb*) *) ΔTamb = ambient temperature change referenced to 23 °C (296 K). Influence of supply voltage: < 0.01 % of span. Influence of load: ≤ 0.001 % of output value per 100 Ω. Reaction time: worst case value (sensor breakage and/or sensor short circuit detection enabled)mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s. Input/Other circuits: basic insulation according to IEC 61010-1, rated insulation voltage 300 Veff. Output/supply, programming input: functional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply.The programming cable provides galvanic isolation so that ground loops are avoided.. Display elements: LEDs. Configuration: via PACTware. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2012 EN 61326-3-2:2008. Degree of protection: IEC 60529:2001. Ambient temperature: -20 ... 70 °C (-4 ... 158 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 100 g. Dimensions: 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2. Height119 mmWidth12.5 mmDepth114 mm: . Height: 119 mm. Width: 12.5 mm. Depth: 114 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Signal typeAnalog input

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Connectionterminals 9+, 10- or power feed module/Power Rail
Rated voltage19 ... 30 V DC Ur
Ripplewithin the supply tolerance
Power dissipation≤ 0.98 W
Power consumptionmax. 0.98 W

Interface

Programming interfaceprogramming socket

Input

Connection sidefield side
Connectionterminals 1, 2, 3, 4
RTDtype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)type Cu10, Cu50, Cu100 (P50353-92)type Ni100 (DIN 43760)
Measuring currentapprox. 200 µA with RTDTypes of measuring2-, 3-, 4-wire connectionLead resistancemax. 50 Ω per lineMeasurement loop monitoringsensor breakage, sensor short-circuit Measuring current
Measuring currentapprox. 200 µA with RTD
Types of measuring2-, 3-, 4-wire connection
Lead resistancemax. 50 Ω per line
Measurement loop monitoringsensor breakage, sensor short-circuit
Thermocouplestype B, E, J, K, N, R, S, T (IEC 584-1: 1995)type L (DIN 43710: 1985)type TXK, TXKH, TXA (P8.585-2001)
Cold junction compensationexternal and internalMeasurement loop monitoringsensor breakage Cold junction compensation
Cold junction compensationexternal and internal
Measurement loop monitoringsensor breakage
Potentiometer0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
Voltageselectable within the range -100 ... 100 mV
Input resistance≥ 1 MΩ (-100 ... 100 mV)

Output

Connection sidecontrol side
Connectionterminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+)
OutputAnalog current output
Current range0 ... 20 mA or 4 ... 20 mAFault signaldownscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)Sourceload 0 ... 550 Ω open-circuit voltage ≤ 18 VSinkVoltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.The maximum value of the resistance is (V - 5)/0.0215 Ω. Current range
Current range0 ... 20 mA or 4 ... 20 mA
Fault signaldownscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)
Sourceload 0 ... 550 Ω open-circuit voltage ≤ 18 V
SinkVoltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.The maximum value of the resistance is (V - 5)/0.0215 Ω.

Transfer characteristics

Deviation
After calibrationPt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection)) thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1.5 K (1.7 K for types R and S)) , includes ± 1.3 K fault of the cold junction compensation (CJC) mV: ± (50 µV + 0.1 % of span)potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes faults due to lead resistance))Influence of ambient temperaturePt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compensation (CJC) includedmV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)potentiometer: ± 0.006 % of span/K ΔTamb*) *) ΔTamb = ambient temperature change referenced to 23 °C (296 K)Influence of supply voltage< 0.01 % of spanInfluence of load≤ 0.001 % of output value per 100 Ω After calibration
After calibrationPt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection)) thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1.5 K (1.7 K for types R and S)) , includes ± 1.3 K fault of the cold junction compensation (CJC) mV: ± (50 µV + 0.1 % of span)potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes faults due to lead resistance))
Influence of ambient temperaturePt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compensation (CJC) includedmV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)potentiometer: ± 0.006 % of span/K ΔTamb*) *) ΔTamb = ambient temperature change referenced to 23 °C (296 K)
Influence of supply voltage< 0.01 % of span
Influence of load≤ 0.001 % of output value per 100 Ω
Reaction timeworst case value (sensor breakage and/or sensor short circuit detection enabled)mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s

Galvanic isolation

Input/Other circuitsbasic insulation according to IEC 61010-1, rated insulation voltage 300 Veff
Output/supply, programming inputfunctional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply.The programming cable provides galvanic isolation so that ground loops are avoided.

Indicators/settings

Display elementsLEDs
Configurationvia PACTware
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2012 EN 61326-3-2:2008
Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-20 ... 70 °C (-4 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Height119 mmWidth12.5 mmDepth114 mm Height
Height119 mm
Width12.5 mm
Depth114 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote