What is the Pepperl Fuchs KCD2-STC-1?

1-channel signal conditioner

24 V DC supply (Power Rail)

Input for 2-wire SMART transmitters and current sources

Output for 4 mA ... 20 mA or 1 V ... 5 V

Housing width 12.5 mm

Up to SIL 2 acc. to IEC/EN 61508

1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Housing width 12.5 mm, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Field device: 2-wire transmitter, Field device [2]: current source, Input signal: 4 ... 20 mA limited to approx. 26 mA

Specifications

General specifications

Order code (Pepperl+Fuchs part number)321413
Signal typeAnalog input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC Ur
Ripple≤ 10 %
Rated current≤ 45 mA at 24 V and 20 mA source mode output Ir
Power dissipation≤ 800 mW
Power consumption≤ 1.1 W

Input

Connection sidefield side
Connectionterminals 1+, 2-; 3+, 4-
Input signal4 ... 20 mA limited to approx. 26 mA
Open circuit voltage/short-circuit currentterminals 1+, 2-: 20 V / 26 mA
Voltage dropterminals 3+, 4- : approx. 5 V
Available voltageterminals 1+, 2-: ≥ 16 V at 20 mA ; ≥ 17 V at 4 mA

Output

Connection sidecontrol side
Connectionterminals 5-, 6+ terminals 5-, 8+ for HART resistor
Load0 ... 525 Ω (10.5 Vmax source mode)
Output signalsource mode: 4 ... 20 mA or 1 ... 5 V (internal resistor: 250 Ω, 0.1 %) sink mode: 4 ... 20 mA, operating voltage 5 ... 30 V For additional internal or external loads (e. g. terminal +8) the voltage drop has to be considered, e. g. 250 Ω x 20 mA = 5 V.
Ripple20 mV rms

Transfer characteristics

Deviationat 20 °C (68 °F) ≤ ± 0.2 % incl. non-linearity and hysteresis (source mode 1 ... 5 V)
Influence of ambient temperature< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode and sink mode 4 ... 20mA) < 0.5 mV/K (-20 ... 70 °C (-4 ... 158 °F)); < 1 mV/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode 1...5 V)
Frequency rangefield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)
Settling time≤ 50 ms
Rise time/fall time≤ 10 ms

Galvanic isolation

Input/Outputbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLED
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2017 EN 61326-3-2:2018
Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2
Height124 mm
Width12.5 mm
Depth114 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KCD2-STC-1: frequently asked questions

When can KCD2-STC-1 be shipped?

KCD2-STC-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KCD2-STC-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KCD2-STC-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-STC-1, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KCD2-ST-Ex2 – Switch Amplifier
Pepperl Fuchs
KCD2-ST-Ex2

Switch Amplifier

Pepperl Fuchs KCD2-STC-1.2O – SMART Transmitter Power Supply
Pepperl Fuchs
KCD2-STC-1.2O

SMART Transmitter Power Supply

Pepperl Fuchs KCD2-STC-1.SP – SMART Transmitter Power Supply
Pepperl Fuchs
KCD2-STC-1.SP

SMART Transmitter Power Supply

Pepperl Fuchs KCD2-STC-Ex1 – SMART Transmitter Power Supply
Pepperl Fuchs
KCD2-STC-Ex1

SMART Transmitter Power Supply

Pepperl Fuchs KCD2-STC-1Price and lead time confirmed within 1 business day
Request a Quote