FX3U-64CCL Mitsubishi MELSEC iQ-F Series Network/communication module
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi MELSEC iQ-F Series – Network/Communication Module |
| Lifecycle | Active mature |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FX3U-64CCL be shipped?
FX3U-64CCL is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FX3U-64CCL in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FX3U-64CCL and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FX3U-64CCL, subject to availability and destination.
The Mitsubishi Electric FX3U-64CCL is a network/communication module in the MELSEC iQ-F Series. Intelligent device station for CC-Link. Mitsubishi Electric has announced its discontinuation (2028/03 To be end of order) — plan spares now; PartnerPLC also sources it on the surplus market after the end of order. Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | MELSEC iQ-F Series |
| Category | Network/communication module |
| Sales status | 2028/03 To be end of order (Mitsubishi Electric) |
| Outline | Intelligent device station for CC-Link |
Specifications
| CC-Link version | Ver. 2.00 (Ver. 1.10 also supported.) |
| Applicable PLC | FX5U, FX5UC, FX3G, FX3U, FX3GC, FX3UC (Ver. 2.20 SER No. 55****, products produced after May 2005) *Only one 64CCL module can be connected to one PLC main unit. [Connecting to the FX5U, FX5UC CPU module] FX5-CNV-BUS or FX5-CNV-BUSC is required to connect to the FX5U/FX5UC CPU module. Select one of the modules according to the system configuration. [Connecting to the connector-type PLC] An FX2NC-CN |
| Number of occupied I/O points | 8 points (Taken from either the input or output points of the PLC.) |
| Mass (weight) | 0.3 kg |
| Communication method | Broadcast polling method |
| Network topology | Bus (RS-485) |
| Transmission speed | 156 Kbps/625 Kbps/2.5 Mbps/5 Mbps/10 Mbps Selectable (set by rotary switch) |
| Transmission format | HDLC compliant |
| Synchronization method | Flag synchronization method |
| Encoding method | NRZI method |
| Error control system | CRC (X 16 +X 12 +X 5 +1) |
| Station type | Intelligent device station |
| Station number | 1 to 64 (set by rotary switch) |
| Number of occupied stations | 1 to 4 (set by rotary switch) |
| Maximum total cable length (maximum transmission distance) | In accordance with the CC-Link specification. |
| Number of remote I/O points | The number of remote input/output points per station is 32 input points and 32 output points. (Single to octuple settings are possible with the extended cyclic setting.) However, the upper 16 points of the final station are occupied by the CC-Link as the system area. |
| Number of remote register points | Four read points and four write points are available as remote registers in one station. (Single to octuple settings are possible with the extended cyclic setting.) |
| Connection cable | CC-Link dedicated cable, CC-Link dedicated high-performance cable, Ver. 1.10 compatible CC-Link dedicated cable Cable types cannot be mixed. |
| Communication with PLC | Execute via the buffer memory using the FROM/TO instruction (or by directly specifying the buffer memory) By FROM and TO instructions (or direct specification of buffer memory) via the buffer memory |
| Allowable instantaneous power failure time | PS1: Operation continues when the instantaneous power failure is shorter than 1 ms. |
| LED | RD, SD, RUN, ERR., L RUN, L ERR., POWER |
| Isolation method | Network bus and internal power supply are insulated each other by photocoupler. |
Power supply specifications
| Power supply | 5 V DC internal power supply: 5 V DC of PLC is not used. (5 V DC is changed from 24 V DC external power supply.) 24 V DC external power supply: Electricity supplied from external terminal block (+20% -15% Ripple Voltage (p-p) 5% or less) |
| Current consumption | 220 mA |
Specifications
| Ambient temperature | 0 to 55°C (32 to 131 °F) when operating and -25 to 75°C (-13 to 167 °F) when stored |
| Ambient humidity | 5 to 95%RH (no condensation) when operating |
| Vibration resistance: Installed on DIN rail: Frequency: 10 to 57 Hz | Half amplitude: 0.035 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) |
| Vibration resistance: Installed on DIN rail: Frequency: 57 to 150 Hz | Acceleration: 4.9 m/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) |
| Vibration resistance: Direct installing: Frequency: 10 to 57 Hz | Half amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) |
| Vibration resistance: Direct installing: Frequency: 57 to 150 Hz | Acceleration: 9.8 m/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) |
| Shock resistance | 147 m/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z |
| Noise resistance | By noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz |
| Dielectric withstand voltage | Between batch of all terminals and ground terminal: 500 V AC for 1 min |
| Insulation resistance | Between batch of all terminals and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester |
| Grounding | Class D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly. |
| Working atmosphere | Free from corrosive or flammable gas and excessive conductive dusts |
| Working altitude | 2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC. |
Downloads & documentation
Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.
Data sheets & manuals
| FX3U-64CCL INSTALLATION MANUAL (JY997D29801) | PDF · 0.34MB |
| FX3U-64CCL USER'S MANUAL (JY997D30401-J) | PDF · 3.02MB |
More Mitsubishi Electric (Factory Automation) parts
Available on requestFX3U-4DA Mitsubishi MELSEC iQ-F Series Analog input/output module
Available on requestFX3U-4DA-ADP Mitsubishi MELSEC-F (FX) Series Analog
Available on requestFX3U-4HSX-ADP Mitsubishi MELSEC-F (FX) Series High-speed counter
Available on requestFX3U-4LC Mitsubishi MELSEC iQ-F Series Analog input/output module
Available on requestFX3U-64DP-M Mitsubishi MELSEC-F (FX) Series Data link/Communication
Available on requestFX3U-64MR/DS Mitsubishi MELSEC-F (FX) Series Main unit
Available on requestFX3U-64MR/ES Mitsubishi MELSEC-F (FX) Series Main unit
Available on requestFX3U-64MR/UA1 Mitsubishi MELSEC-F (FX) Series Main unit