B&R X20DS4387

I/O module, IO-Link master with 4 IO-Link interfaces

MPN
X20DS4387
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the B&R X20DS4387?

4 IO-Link interfaces per module

Each interface can be configured as a standard input or output

Seamless integration in POWERLINK

Supports all transfer rates

IO-Link is a standardized communication system for connecting intelligent sensors and actuators in an automation system. The standardization includes electrical connection data as well as a digital communication protocol, which is used by the sensors and actuators in the automation system for data exchange.

An IO-Link system consists of an IO-Link master and one or more IO-Link devices, i.e. sensors and actuators. The IO-Link master makes the interface available for higher level control and controls communication with the connected IO-Link devices.

An IO-Link device is an intelligent sensor or actuator. With regard to IO-Link, "intelligent" means that a device possesses a series number or parameter data (sensitivity, switching delays or characteristic curves), which can be written to or read via the IO-Link protocol.

Process optimization

The use of intelligent sensors and actuators contributes to process optimization. Process optimization means that downtimes should be kept as short as possible. These consist mainly of standstills due to errors and setup times.

Integrated communication down to the IO-Link devices offers many advantages in error diagnostics. Errors are detected much faster than before. If a sensor or actuator must be replaced, lengthy configuration work is no longer necessary after the change thanks to a potentiometer, or a configuration tool and laptop. After changing the sensor/actuator, the parameters are automatically transferred to the sensor.

This parameter download is not only beneficial when errors occur. It can also be used for changing parameters when a load change is performed. This shortens setup times, making product changes and small batches more economical.

Integrating IO-Link into the X20 System

IO-Link is integrated in the X20 system using this digital module. All 4 channels are IO-Link interfaces, but can also be used as standard inputs or outputs. The specified 3-wire connections can be ideally implemented thanks to the X20 connector system with 12 terminal points per module. All specified transfer rates are also supported.

POWERLINK integration

IO-Link doesn't stop at the I/O module. It must be integrated in the higher-level bus system to fully utilize the benefits. When using POWERLINK, access is made possible via device description files in XML format.

Specifications

Short description

I/O moduleIO-Link master with 4 IO-Link interfaces

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – IO-Link operating stateYes, using LED status indicator and software
Diagnostics – C/Q statusYes, using LED status indicator and software
Cable specification – Cable type3-pin standard sensor cable
Cable specification – Cable lengthMax. 20 m
Cable specification – Line capacitanceMax. 3 nF
Cable specification – Loop resistanceMax. 6 Ω
Power consumption – Bus0.01 W
Power consumption – Internal I/O1.6 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – KCYes
B&R ID code0xA38E
Status indicatorsIO-Link, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-

Sensor/Actuator power supply

VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.3 AMax. 1 VDC
Power consumptionMax. 9 W per interface
Short-circuit proofYes

IO-Link in master mode

Transfer rates – COM14.8 kbaud
Transfer rates – COM238.4 kbaud
Transfer rates – COM3230.4 kbaud
Limit values for COM3 – Max. connection capacity47 nF (cable and device)
Limit values for COM3 – Max. load100 Ω / 0.3 A
Data format1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit
Bus level24 VDC (active), 0 VDC (resting voltage)
IO-Link device power supply24 VDC / Max. 0.3 A per interface (fused)

IO-Link in master mode or in SIO mode "digital output"

Switching delay – 0 → 1<10 µs
Switching delay – 1 → 0<10 µs
VariantBipolar, positive and negative switching
DiagnosticsOutput monitoring with 100 ns delay and internal protection of the semiconductor with 100 µs delay
Peak short-circuit current<1.5 A
Residual voltage<1.5 VDC at nominal current 0.2 A
Switching voltageI/O power supply minus voltage drop for short-circuit protection and semiconductor switch
Voltage drop on semiconductor switchMax. 1.5 VDC at 0.2 A
Switching frequencyTyp. 25 kHz ; 300 kHz in IO-Link master mode
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 10 ms (depends on the module temperature)
Braking voltage when switching off inductive loadsTyp. 52 VDC
Insulation voltage between IO-Link and bus500 V eff

IO-Link in SIO mode "Digital output"

Nominal voltage24 VDC
Nominal output current0.2 A
Total nominal current0.4 A
Output circuitSink or source
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads
Actuator power supply24 VDC / Max. 0.3 A per interface (fused)

IO-Link in SIO mode "digital input"

Input filter – Hardware100 ns
Input filter – Software-
Switching threshold – Low<8 VDC
Switching threshold – High>13 VDC
Nominal voltage24 VDC
Input circuitSink
Sensor power supply24 VDC / Max. 0.3 A per interface (fused)
Input voltage24 VDC -15% / +20%
Input current at 24 VDCTyp. 5 mA
Input resistanceTyp. 4.8 kΩ
Insulation voltage between IO-Link and bus500 V eff

Electrical properties

Electrical isolationBus isolated from IO-Link ; IO-Link not isolated from IO-Link

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation0 to 55°C
Temperature – Vertical mounting orientation0 to 45°C
Temperature – Derating-
Temperature – Storage-25 to 70°C
Temperature – Transport-25 to 70°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

X20DS4387: frequently asked questions

When can X20DS4387 be shipped?

X20DS4387 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20DS4387 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20DS4387 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20DS4387, subject to availability and destination.

More B&R parts

B&R X20DS1119 – I/O module, 3 digital 5 V (symmetrical) channels…
B&R
X20DS1119

I/O module, 3 digital 5 V (symmetrical) channels…

B&R X20DS1319 – I/O module, 4 digital input channels
B&R
X20DS1319

I/O module, 4 digital input channels

B&R X20DS1828 – I/O module, 1x HIPERFACE interface
B&R
X20DS1828

I/O module, 1x HIPERFACE interface

B&R X20DS1928 – I/O module, 1x EnDat interface
B&R
X20DS1928

I/O module, 1x EnDat interface

B&R X20DS4389 – I/O module, 4 digital input channels
B&R
X20DS4389

I/O module, 4 digital input channels

B&R X20DS438A – I/O module, IO-Link master with 4 IO-Link interfaces
B&R
X20DS438A

I/O module, IO-Link master with 4 IO-Link interfaces

B&R X20DS838A – I/O module, IO-Link master with 8 IO-Link interfaces
B&R
X20DS838A

I/O module, IO-Link master with 8 IO-Link interfaces

B&R X20EDS410 – Interfaces, 1x USB 3.0, 2x Gigabit Ethernet
B&R
X20EDS410

Interfaces, 1x USB 3.0, 2x Gigabit Ethernet

B&R X20DS4387Price and lead time confirmed within 1 business day
Request a Quote