B&R X20DS1119
I/O module, 3 digital 5 V (symmetrical) channels…
- MPN
- X20DS1119
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
What is the B&R X20DS1119?
3 digital 5 V channels, configurable as inputs or outputs
2 digital 24 V input channels
1 universal counter pair (2 event counters, AB counters or up/down counters)
Linear motion generator (A/B, direction/frequency) with one reference pulse
SSI absolute encoder
NetTime timestamp: Input data, target position, position change, edge change, counter change
This module is a multifunction digital signal processor module. It can be used extremely flexibly for a wide variety of tasks involving digital signal processing or digital signal generation. Two primary example applications include controlling stepper output stages with pulse and direction signals or using as encoder emulation. In this application, for example, frequency inverters or servo axes with the speed follow function can follow a real or virtual master axis.
An additional major feature is the module's integrated timestamp function. It allows counter ramps curves to be generated virtually independently of bus cycle times during encoder emulation, for example. Only the target counter value and moment when it should be reached are transferred. The module automatically generates the corresponding counter values at the appropriate time, precisely in microsecond resolution and independently of the bus clock.
Specifications
Short description
| I/O module | 3 digital 5 V (symmetrical) channels configurable as inputs or outputs, 2 digital 24 V (asymmetrical) input channels, 1 universal counter pair (2 event counters, AB counter or up/down counter), linear motion generator (A/B, direction/frequency) with 1 reference pulse, SSI absolute encoder, relative or absolute moments of input edges with microsecond resolution, time-triggered I/O, I/O oversampling |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Inputs/Outputs | Yes, using LED status indicator |
| Power consumption – Bus | 0.01 W |
| Power consumption – Internal I/O | 1.5 W |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| Certifications – KC | Yes |
| B&R ID code | 0xA067 |
| Status indicators | I/O function per channel, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| Type of signal lines | Shielded lines must be used for all signal lines. |
Linear motion generator
| Quantity | 1 |
| Encoder outputs | 5 V, symmetrical (A/B, direction/frequency) |
| Counter size | 16/32-bit |
SSI absolute encoder
| Encoder power supply – 5 VDC | ±5%, module-internal, max. 300 mA |
| Encoder power supply – 24 VDC | Module-internal, max. 300 mA |
| Quantity | 1 |
| Counter size | Up to 32-bit depending on encoder |
| Max. transfer rate | 1 Mbit/s |
| Encoder signal | 5 V, symmetrical |
Digital inputs 5 VDC
| Input filter – Hardware | ≤200 ns |
| Input filter – Software | - |
| Quantity | Up to 3, configuration as input or output using software |
| Nominal voltage | 5 VDC differential signal, EiA RS485 standard |
| Input characteristics per EN 61131-2 | Type 1 |
| Input frequency | 600 kHz |
| Common-mode range | -7 V ≤ V CM ≤ +12 V |
| Insulation voltage between encoder and bus | 500 V eff |
| Overload characteristics of encoder power supply | Short-circuit proof, overload-proof |
| Additional functions | SSI absolute encoder, universal counter pair |
Digital inputs 24 VDC
| Input filter – Hardware | ≤2 µs |
| Input filter – Software | - |
| Switching threshold – Low | <5 VDC |
| Switching threshold – High | >15 VDC |
| Quantity | 2 |
| Nominal voltage | 24 VDC |
| Input characteristics per EN 61131-2 | Type 1 |
| Input circuit | Sink |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Approx. 3.4 mA |
| Input resistance | Approx. 7.19 kΩ |
| Input frequency | 100 kHz |
| Insulation voltage between channel and bus | 500 V eff |
| Additional functions | Latch function for universal counter pair |
Universal counter pair
| Evaluation – AB counter | 4xCounter"."> (note: Problems may occur during evaluation due to the system at an input frequency greater than 500 kHz. For additional information, see section) |
| Evaluation – Event counters | 2x |
| Evaluation – Up/Down counter | 2x |
| Encoder power supply – 5 VDC | ±5%, module-internal, max. 300 mA |
| Encoder power supply – 24 VDC | Module-internal, max. 300 mA |
| Quantity | 1 |
| Operating modes | 2x event counter, up/down counter, AB counter |
| Encoder inputs | 5 V, symmetrical |
| Counter size | 16/32-bit |
| Input frequency | Max. 600 kHz |
Digital outputs 5 VDC
| Quantity | Up to 3, configuration as input or output using software |
| Type | 5 VDC differential signal, EiA RS485 standard |
| Output circuit | Sink and/or source |
| Output protection | Short-circuit protection |
| Variant | Push/Pull/Push-Pull |
| Nominal voltage | 5 VDC |
| Output current | Max. 65 mA |
| Diagnostic status | Output is readable. |
| Switching frequency | Max. 500 kHz |
| Insulation voltage between channel and bus | 500 V eff |
| Switching voltage | 5 VDC differential signal, EiA RS485 standard |
| Additional functions | SSI absolute encoder, linear motion generator |
Electrical properties
| Electrical isolation | Channel isolated from bus; Channel not isolated from channel |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | - |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately. |
| Pitch | 12.5 +0.2 mm |
Accessories
Required accessories (order separately)
| X20BM15 | Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe… |
| X20BM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (16)
- 2226379 CSA Certificate of Compliance X20 X67
- 64331_A1 BV Certificate of Compliance X20
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
- RINA Type Approval Certificate - X20 / Power Panel T30
- Safe cutoff of potential groups
- TAA00000BJ DNV Type Approval Certificate X20
- UK Declaration PLC X20
- X20, X67 KC certificates
X20DS1119: frequently asked questions
When can X20DS1119 be shipped?
X20DS1119 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20DS1119 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20DS1119 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20DS1119, subject to availability and destination.