B&R X20DS438A

I/O module, IO-Link master with 4 IO-Link interfaces

MPN
X20DS438A
€592.54excl. VAT & shipping
In stock — 1 available·Ships within 1 business day
Choose condition
Need a larger quantity or a formal quote?
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the B&R X20DS438A?

4 IO-Link devices

4 digital channels, can be configured as input or output

24 VDC and GND for sensor/actuator supply

NetTime timestamps: IO-Link data

The module is an IO-Link master that allows intelligent sensors and actuators to be connected to the X20 system in accordance with the IO-Link standard. The module can be used to operate up to 4 IO-Link devices. All IO-Link channels can be used either as standard digital inputs or outputs.

Specifications

Short description

I/O moduleIO-Link master with 4 IO-Link interfaces

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – IO-Link operating stateYes, using LED status indicator and software
Diagnostics – C/Q statusYes, using LED status indicator and software
Cable specification – Cable type3-pin standard sensor cable, unshielded
Cable specification – Cable lengthMax. 20 m
Cable specification – Line capacitanceMax. 3 nF
Cable specification – Loop resistanceMax. 6 Ω
Power consumption – Bus0.01 W
Power consumption – Internal I/O0.71 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – DNVTemperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
Certifications – CCSYes
Certifications – LRENV1
Certifications – KRYes
Certifications – ABSYes
Certifications – BVEC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck
B&R ID code0xCAC0
Status indicatorsIO-Link, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-

Sensor/Actuator power supply

Overload protection – Switch-off delayConfigurable using software
Overload protection – Switch-off durationConfigurable using software
VoltageI/O power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 0.5 AMax. 0.3 V
Power consumptionMax. 12 W per IO-Link interface
Short-circuit proofYes

IO-Link in master mode

Transfer rates – COM14.8 kbaud
Transfer rates – COM238.4 kbaud
Transfer rates – COM3230.4 kbaud
Limit values for COM3 – Max. connection capacity22 nF (cable + IO-Link device)
Limit values for COM3 – Max. load96 Ω / 250 mA
Data format1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit
Bus level24 VDC (active), 0 VDC (resting voltage)

IO-Link in master mode or in SIO mode "digital output"

Switching delay – 0 → 1<10 µs
Switching delay – 1 → 0<10 µs
VariantBipolar, positive and negative switching
Peak short-circuit current<1.3 A
Residual voltage<0.7 VDC at nominal current 0.25 A
Switching voltageI/O power supply minus voltage drop for short-circuit protection and semiconductor switch
Voltage drop on semiconductor switchMax. 0.5 VDC at 0.25 A
Switching frequencyTyp. 25 kHz ; 300 kHz in IO-Link master mode
Switch-on in the event of overload shutdown or short-circuit shutdownConfigurable with software
Insulation voltage between IO-Link and bus500 V eff

IO-Link in SIO mode "Digital output"

Nominal voltage24 VDC
Nominal output current0.25 A
Total nominal currentMax. 1 A
Output circuitSink or source
Switching frequency (resistive load)Max. 500 Hz
Output protectionThermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads (note: Cutoff current on overload: Between 0.3 A and 0.8 A.)

IO-Link in SIO mode "digital input"

Input filter – Hardware300 ns
Input filter – Software-
Switching threshold – Low<5 VDC
Switching threshold – High>15 VDC
Nominal voltage24 VDC
Input characteristics per EN 61131-2Type 1
Input circuitSink
Input voltage24 VDC -15% / +20%
Input current at 24 VDCTyp. 4 mA
Input resistanceTyp. 6 kΩ
Insulation voltage between IO-Link and bus500 V eff

Electrical properties

Electrical isolationBus isolated from IO-Link ; IO-Link not isolated from IO-Link

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C
Temperature – Vertical mounting orientation-25 to 50°C
Temperature – Derating-
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (14)

X20DS438A: frequently asked questions

When can X20DS438A be shipped?

X20DS438A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20DS438A in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20DS438A and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20DS438A, subject to availability and destination.

More B&R parts

B&R X20DS1828 – I/O module, 1x HIPERFACE interface
B&R
X20DS1828

I/O module, 1x HIPERFACE interface

B&R X20DS1928 – I/O module, 1x EnDat interface
B&R
X20DS1928

I/O module, 1x EnDat interface

B&R X20DS4387 – I/O module, IO-Link master with 4 IO-Link interfaces
B&R
X20DS4387

I/O module, IO-Link master with 4 IO-Link interfaces

B&R X20DS4389 – I/O module, 4 digital input channels
B&R
X20DS4389

I/O module, 4 digital input channels

B&R X20DS838A – I/O module, IO-Link master with 8 IO-Link interfaces
B&R
X20DS838A

I/O module, IO-Link master with 8 IO-Link interfaces

B&R X20EDS410 – Interfaces, 1x USB 3.0, 2x Gigabit Ethernet
B&R
X20EDS410

Interfaces, 1x USB 3.0, 2x Gigabit Ethernet

B&R X20EDS410-4G – Interfaces, 1x USB 3.0, 2x Gigabit Ethernet
B&R
X20EDS410-4G

Interfaces, 1x USB 3.0, 2x Gigabit Ethernet

B&R X20EM0611 – Interfaces, 1x RS485, 1x Ethernet (2-port switch)
B&R
X20EM0611

Interfaces, 1x RS485, 1x Ethernet (2-port switch)

B&R X20DS438A€592.54
Buy Now