B&R X20DS1928
I/O module, 1x EnDat interface
- MPN
- X20DS1928
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
What is the B&R X20DS1928?
EnDat 2.1 and EnDat 2.2 encoder interface
Encoder input monitoring
5 VDC and GND for encoder supply
NetTime timestamp: Position time
The module is equipped with an EnDat encoder interface. The module automatically detects whether an encoder is connected with EnDat 2.1 or EnDat 2.2. This module can be used to evaluate encoders installed in B&R servo motors as well as encoders for external axes (encoders that scan any machine movement). The input signals are monitored. This makes it possible to detect open or shorted lines as well as encoder supply failures.
Specifications
Short description
| I/O module | 1x EnDat interface |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Counting direction | Yes, using LED status indicator |
| Power consumption – Bus | 0.01 W |
| Power consumption – Internal I/O | 1.3 W |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – KC | Yes |
| B&R ID code | 0xA912 |
| Status indicators | Counting direction, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| Type of signal lines | Shielded lines must be used for all signal lines. |
Encoder inputs
| Sine/Cosine inputs – Signal transmission | Differential signals, symmetrical |
| Sine/Cosine inputs – Signal frequency | DC up to 400 kHz |
| Sine/Cosine inputs – Differential voltage | 1 V SS |
| Sine/Cosine inputs – Common-mode voltage | Max. ±10 V |
| Sine/Cosine inputs – Terminating resistor | 120 Ω |
| Type | EnDat 2.1/2.2 |
| Angular position resolution | 13-bit, with a signal of 1 V SS |
| Encoder monitoring | Yes |
| Max. encoder cable length | 10 m, with wire cross section 4x 2x 0.14 mm 2 and 1x 2x 0.5 mm 2 |
Encoder power supply
| Protective measures – Overload-proof | Yes |
| Protective measures – Short-circuit proof | Yes |
| Output voltage | 5 V (±5%) |
| Load capacity | 300 mA |
Serial EnDat interface
| Signal transmission | 5 VDC differential signal, EiA RS485 standard |
| Transmission status | See the EnDat specification. |
Electrical properties
| Electrical isolation | Channel isolated from bus ; Channel not isolated from channel |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | See section "Derating". |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately. |
| Pitch | 12.5 +0.2 mm |
Accessories
Required accessories (order separately)
| X20BM15 | Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe… |
| X20BM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
X20DS1928: frequently asked questions
When can X20DS1928 be shipped?
X20DS1928 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20DS1928 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20DS1928 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20DS1928, subject to availability and destination.