| MPN | product designation / according to UL file | design of the overcurrent release | power loss [W] / maximum | power loss [W] / for rated value of the current / at AC / in hot operating state / per pole | Net Weight |
|---|---|---|---|---|---|
| 3VA6325-8HN41-2AA0 | LJAE | ETU350 | 27 W | 9 W | 6.9 kg |
| 3VA6325-8HN41-0AA0 | LJAE | ETU350 | 27 W | 9 W | 6.9 kg |
| 3VA6325-8HM31-2AA0 | LJAE | ETU330 | 27 W | 9 W | 5.3 kg |
| 3VA6115-5KQ41-2AA0 | MDAE | ETU860 | 29 W | 9.67 W | 2.9 kg |
| 3VA6115-5KQ41-0AA0 | MDAE | ETU860 | 29 W | 9.67 W | 3.2 kg |
| 3VA6110-5JQ31-2AA0 | MDAE | ETU560 | 13 W | 4.33 W | 2.3 kg |
| 3VA6110-5JQ31-0AA0 | MDAE | ETU560 | 13 W | 4.33 W | 2.084 kg |
| 3VA6110-5JP41-2AA0 | MDAE | ETU550 | 13 W | 4.33 W | 2.9 kg |
| 3VA6110-5JP41-0AA0 | MDAE | ETU550 | 13 W | 4.33 W | 3.2 kg |
| 3VA6210-7HN31-2AA0 | CFAE | ETU350 | 6.7 W | 2.23 W | 2.3 kg |
| 3VA6210-7HN31-0AA0 | CFAE | ETU350 | 6.7 W | 2.23 W | 2.5 kg |
| 3VA6210-7HM41-0AA0 | CFAE | ETU330 | 6.7 W | 2.23 W | 3.2 kg |
| 3VA6110-8KQ31-2AA0 | LDAE | ETU860 | 13 W | 4.33 W | 2.3 kg |
| 3VA6140-6KL31-0AA0 | HDAE | ETU820 | 2.4 W | 0.8 W | 2.5 kg |
| 3VA6140-6JT41-2AA0 | HDAE | ETU556 | 2.4 W | 0.8 W | 2.9 kg |
| 3VA6140-6JT41-0AA0 | HDAE | ETU556 | 2.4 W | 0.8 W | 3.2 kg |
| 3VA6115-5KL41-2AA0 | MDAE | ETU820 | 29 W | 9.67 W | 2.9 kg |
| 3VA5260-5ED31-2AA0 | MFAS | TM210 | 22 W | 7.3 W | 2 100 g |
| 3VA5260-5ED31-0AA0 | MFAS | TM210 | 22 W | 7.3 W | 2 kg |
| 3VA5102-1MH31-0AA0 | HEAP | TM120M | 4 W | 1.43 W | 918 g |
| 3VA5325-7GC41-2AA0 | CJAS | TM230 | 59 W | 19.57 W | 6 820 g |
| 3VA5325-7GC41-0AA0 | CJAS | TM230 | 59 W | 19.57 W | 6.82 kg |
| 3VA5325-7EF41-2AA0 | CJAS | TM240 | 59 W | 19.57 W | 6 820 g |
| 3VA6340-0KQ31-0AA0 | EJAE | ETU860 | 70 W | 23.33 W | 5.3 kg |
Common to all listed parts
| product designation | Molded-case circuit breaker |
| design of the load switch / according to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type) | Yes |
| insulation voltage / rated value | 800 V |
| operating voltage / at AC / rated value | 690 V |
| arrangement of electrical connectors / for main current circuit | Without connection |
| type of electrical connection / for main current circuit | Without |
| number of CO contacts / for auxiliary contacts | 0 |
| product extension / optional / motor drive | Yes |