Siemens 6ES7531-7QF00-0AB0

SIMATIC S7-1500 Analog input module, AI 8xU/I/R/RTD BA, 16 bit resolution, Accuracy 0.5%

MPN
6ES7531-7QF00-0AB0
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 6ES7531-7QF00-0AB0?

SIMATIC S7-1500 Analog input module, AI 8xU/I/R/RTD BA, 16 bit resolution, Accuracy 0.5%, 8 channels in groups of 8; Common mode voltage 4 V DC, Diagnostics; Hardware interrupts; Delivery including infeed element, shield bracket and shield terminal: Front connector (screw terminals or push-in) to be ordered separately

Specifications

General information

Product type designationAI 8xU/I/R/RTD BA
HW functional statusFS01
Firmware versionV1.0.0
Firmware version — FW update possibleYes
Product function — I&M dataYes; I&M0 to I&M3
Product function — Isochronous modeNo
Product function — Prioritized startupNo
Product function — Measuring range scalableNo
Product function — Scalable measured valuesNo
Product function — Adjustment of measuring rangeNo
Engineering with — STEP 7 TIA Portal configurable/integrated from versionV15.1 / V16
Engineering with — STEP 7 configurable/integrated from versionV5.5 SP3 / -
Engineering with — PROFIBUS from GSD version/GSD revisionV1.0 / V5.1
Engineering with — PROFINET from GSD version/GSD revisionV2.3 / -
Operating mode — OversamplingNo
Operating mode — MSIYes

CiR - Configuration in RUN

Reparameterization possible in RUNYes
Calibration possible in RUNNo

Input current

Current consumption, max.0 mA; no supply required

Power

Power consumption from the backplane bus0.85 W

Power loss

Power loss, typ.0.9 W

Address area

Address space per module — Inputs16 byte; typical, maximum 68 bytes, see manual for details
Address space per module — Outputs0 byte

Analog inputs

Number of analog inputs8
Number of analog inputs — For current measurement8
Number of analog inputs — For voltage measurement8
Number of analog inputs — For resistance/resistance thermometer measurement8
permissible input voltage for voltage input (destruction limit), max.12 V; 12 V continuous, 30 V for max. 1 s
permissible input current for current input (destruction limit), max.40 mA
Constant measurement current for resistance-type transmitter, typ.230 ... 370 µA
Technical unit for temperature measurement adjustableYes; °C/°F/K
Analog input with oversamplingNo
Standardization of measured valuesNo
Input ranges (rated values), voltages — 0 to +5 VNo
Input ranges (rated values), voltages — 0 to +10 VNo
Input ranges (rated values), voltages — 1 V to 5 VYes
Input ranges (rated values), voltages — 1 V to 5 V — Input resistance (1 V to 5 V)10 MΩ
Input ranges (rated values), voltages — 1 V to +1 VYes
Input ranges (rated values), voltages — 1 V to +1 V — Input resistance (-1 V to +1 V)10 MΩ
Input ranges (rated values), voltages — 10 V to +10 VYes
Input ranges (rated values), voltages — 10 V to +10 V — Input resistance (-10 V to +10 V)10 MΩ
Input ranges (rated values), voltages — 2.5 V to +2.5 VNo
Input ranges (rated values), voltages — 25 mV to +25 mVNo
Input ranges (rated values), voltages — 250 mV to +250 mVNo
Input ranges (rated values), voltages — 5 V to +5 VYes
Input ranges (rated values), voltages — 5 V to +5 V — Input resistance (-5 V to +5 V)10 MΩ
Input ranges (rated values), voltages — 50 mV to +50 mVYes
Input ranges (rated values), voltages — 50 mV to +50 mV — Input resistance (-50 mV to +50 mV)10 MΩ
Input ranges (rated values), voltages — 500 mV to +500 mVYes
Input ranges (rated values), voltages — 500 mV to +500 mV — Input resistance (-500 mV to +500 mV)10 MΩ
Input ranges (rated values), voltages — 80 mV to +80 mVNo
Input ranges (rated values), currents — 0 to 20 mAYes
Input ranges (rated values), currents — 0 to 20 mA — Input resistance (0 to 20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), currents — 20 mA to +20 mAYes
Input ranges (rated values), currents — 20 mA to +20 mA — Input resistance (-20 mA to +20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), currents — 4 mA to 20 mAYes
Input ranges (rated values), currents — 4 mA to 20 mA — Input resistance (4 mA to 20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), thermocouples — type BNo
Input ranges (rated values), thermocouples — type CNo
Input ranges (rated values), thermocouples — Type ENo
Input ranges (rated values), thermocouples — Type JNo
Input ranges (rated values), thermocouples — Type KNo
Input ranges (rated values), thermocouples — Type LNo
Input ranges (rated values), thermocouples — Type NNo
Input ranges (rated values), thermocouples — Type RNo
Input ranges (rated values), thermocouples — Type SNo
Input ranges (rated values), thermocouples — Type TNo
Input ranges (rated values), thermocouples — Type UNo
Input ranges (rated values), thermocouples — Type TXK/TXK(L) to GOSTNo
Input ranges (rated values), resistance thermometer — Cu 10No
Input ranges (rated values), resistance thermometer — Cu 10 according to GOSTNo
Input ranges (rated values), resistance thermometer — Cu 50No
Input ranges (rated values), resistance thermometer — Cu 50 according to GOSTNo
Input ranges (rated values), resistance thermometer — Cu 100No
Input ranges (rated values), resistance thermometer — Cu 100 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 10No
Input ranges (rated values), resistance thermometer — Ni 10 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 100Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Ni 100 — Input resistance (Ni 100)10 MΩ
Input ranges (rated values), resistance thermometer — Ni 100 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 1000Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Ni 1000 — Input resistance (Ni 1000)10 MΩ
Input ranges (rated values), resistance thermometer — Ni 1000 according to GOSTNo
Input ranges (rated values), resistance thermometer — LG-Ni 1000Yes; Standard/climate
Input ranges (rated values), resistance thermometer — LG-Ni 1000 — Input resistance (LG-Ni 1000)10 MΩ
Input ranges (rated values), resistance thermometer — Ni 120No
Input ranges (rated values), resistance thermometer — Ni 120 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 200No
Input ranges (rated values), resistance thermometer — Ni 200 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 500No
Input ranges (rated values), resistance thermometer — Ni 500 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 10No
Input ranges (rated values), resistance thermometer — Pt 10 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 50No
Input ranges (rated values), resistance thermometer — Pt 50 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 100Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Pt 100 — Input resistance (Pt 100)10 MΩ
Input ranges (rated values), resistance thermometer — Pt 100 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 1000Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Pt 1000 — Input resistance (Pt 1000)10 MΩ
Input ranges (rated values), resistance thermometer — Pt 1000 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 200No
Input ranges (rated values), resistance thermometer — Pt 200 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 500No
Input ranges (rated values), resistance thermometer — Pt 500 according to GOSTNo
Input ranges (rated values), resistors — 0 to 150 ohmsNo
Input ranges (rated values), resistors — 0 to 300 ohmsNo
Input ranges (rated values), resistors — 0 to 600 ohmsYes
Input ranges (rated values), resistors — 0 to 600 ohms — Input resistance (0 to 600 ohms)10 MΩ
Input ranges (rated values), resistors — 0 to 3000 ohmsNo
Input ranges (rated values), resistors — 0 to 6000 ohmsYes
Input ranges (rated values), resistors — 0 to 6000 ohms — Input resistance (0 to 6000 ohms)10 MΩ
Input ranges (rated values), resistors — PTCYes
Input ranges (rated values), resistors — PTC — Input resistance (PTC)10 MΩ
Cable length — shielded, max.200 m; 50 m at 50 mV

Analog value generation for the inputs

Measurement principleintegrating
Integration and conversion time/resolution per channel — Resolution with overrange (bit including sign), max.16 bit
Integration and conversion time/resolution per channel — Integration time, parameterizableYes
Integration and conversion time/resolution per channel — Integration time (ms)2,5 / 16,67 / 20 / 100 ms
Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms)10 / 24 / 27 / 107 ms
Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms) — additional conversion time for wire-break monitoring4 ms (to be considered in R/RTD/U 1 to 5 V measurement)
Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms) — additional conversion time for resistance measurement8 ms
Integration and conversion time/resolution per channel — Interference voltage suppression for interference frequency f1 in Hz400 / 60 / 50 / 10 Hz
Smoothing of measured values — Number of smoothing levels4
Smoothing of measured values — ParameterizableYes
Smoothing of measured values — Step: NoneYes
Smoothing of measured values — Step: lowYes
Smoothing of measured values — Step: MediumYes
Smoothing of measured values — Step: HighYes

Encoder

Connection of signal encoders — for voltage measurementYes
Connection of signal encoders — for current measurement as 2-wire transducerYes; with external supply
Connection of signal encoders — for current measurement as 4-wire transducerYes
Connection of signal encoders — for resistance measurement with two-wire connectionYes; Only for PTC
Connection of signal encoders — for resistance measurement with three-wire connectionYes; All measuring ranges except PTC; internal compensation of the cable resistances
Connection of signal encoders — for resistance measurement with four-wire connectionNo

Errors/accuracies

Linearity error (relative to input range), (+/-)0.1 %
Temperature error (relative to input range), (+/-)0.006 %/K
Crosstalk between the inputs, max.-50 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.1 %
Operational error limit in overall temperature range — Voltage, relative to input range, (+/-)0.5 %
Operational error limit in overall temperature range — Current, relative to input range, (+/-)0.5 %
Operational error limit in overall temperature range — Resistance, relative to input range, (+/-)0.5 %
Operational error limit in overall temperature range — Resistance thermometer, relative to input range, (+/-)Ptxxx Standard: ±1.2 K, Ptxxx Climate: ±0.8 K, Nixxx Standard: ±0.8 K, Nixxx Climate: ±0.8 K
Basic error limit (operational limit at 25 °C) — Voltage, relative to input range, (+/-)0.3 %
Basic error limit (operational limit at 25 °C) — Current, relative to input range, (+/-)0.3 %
Basic error limit (operational limit at 25 °C) — Resistance, relative to input range, (+/-)0.3 %
Basic error limit (operational limit at 25 °C) — Resistance thermometer, relative to input range, (+/-)Ptxxx Standard: ±1.0 K, Ptxxx Climate: ±0.5 K, Nixxx Standard: ±0.5 K, Nixxx Climate: ±0.5 K
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Series mode interference (peak value of interference < rated value of input range), min.40 dB
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode voltage, max.4 V
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode interference, min.60 dB

Interrupts/diagnostics/status information

Diagnostics functionYes
Alarms — Diagnostic alarmYes
Alarms — Limit value alarmYes; two upper and two lower limit values in each case
Diagnoses — Monitoring the supply voltageNo
Diagnoses — Wire breakYes; Only for 1 ... 5 V, 4 ... 20 mA, R, and RTD
Diagnoses — Short-circuitNo
Diagnoses — Group errorNo
Diagnoses — Overflow/UnderflowYes
Diagnostics indication LED — RUN LEDYes; green LED
Diagnostics indication LED — ERROR LEDYes; red LED
Diagnostics indication LED — MAINT LEDNo
Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED)No
Diagnostics indication LED — Channel status displayYes; green LED
Diagnostics indication LED — for channel diagnosticsYes; red LED
Diagnostics indication LED — for module diagnosticsYes; red LED

Potential separation

Potential separation channels — between the channelsNo
Potential separation channels — between the channels, in groups of8
Potential separation channels — between the channels and backplane busYes

Permissible potential difference

between the inputs (UCM)8 V DC
Between the inputs and MANA (UCM)4 V DC

Isolation

Isolation tested with707 V DC (type test)

Standards, approvals, certificates

Siemens Eco Profile (SEP)Siemens EcoTech
Suitable for applications according to AMS 2750No
Suitable for applications according to CQI-9No
Ecological footprint — environmental product declarationYes
Ecological footprint — Global warming potential — global warming potential, (total) [CO2 eq]38.6 kg
Ecological footprint — Global warming potential — global warming potential, (during production) [CO2 eq]14.4 kg
Ecological footprint — Global warming potential — global warming potential, (during operation) [CO2 eq]24.6 kg
Ecological footprint — Global warming potential — global warming potential, (after end of life cycle) [CO2 eq]-0.44 kg

Security

signed firmware updateNo
securely removing dataNo
data integrityNo

Ambient conditions

Ambient temperature during operation — horizontal installation, min.-30 °C; From FS05
Ambient temperature during operation — horizontal installation, max.60 °C
Ambient temperature during operation — vertical installation, min.-30 °C; From FS05
Ambient temperature during operation — vertical installation, max.40 °C
Altitude during operation relating to sea level — Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Absolute humidity — dew point, min.-60 °C; suitable for dry room applications

Dimensions

Width35 mm
Height147 mm
Depth129 mm

Weights

Weight, approx.250 g

Other

Note:please order front connectors (screw-in/push-in) separately

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

6ES7531-7QF00-0AB0: frequently asked questions

When can 6ES7531-7QF00-0AB0 be shipped?

6ES7531-7QF00-0AB0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 6ES7531-7QF00-0AB0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 6ES7531-7QF00-0AB0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6ES7531-7QF00-0AB0, subject to availability and destination.

More Siemens parts

Siemens 6ES7528-0AA70-7AA0 – SIMATIC ET 200MP, spare part Front door for IM 155-5 (6ES7155-5AA00-0AB0) 5 units per packing unit
Siemens
6ES7528-0AA70-7AA0

SIMATIC ET 200MP, spare part Front door for IM 155-5…

Siemens 6ES7528-0AA80-7AA0 – SIMATIC S7-1500, spare part Front door for 35 mm width Power supply and PTP CP 5 units per packing unit
Siemens
6ES7528-0AA80-7AA0

SIMATIC S7-1500, spare part Front door for 35 mm width…

Siemens 6ES7531-7KF00-0AB0 – SIMATIC S7-1500 analog input module AI 8xU/I/RTD/TC ST, 16 bit resolution, accuracy 0.3%
Siemens
6ES7531-7KF00-0AB0

SIMATIC S7-1500 analog input module AI 8xU/I/RTD/TC ST

Siemens 6ES7531-7QD00-0AB0 – SIMATIC S7-1500 Analog input module AI 4xU/I/RTD/TC ST, 16 bit resolution, Accuracy 0.3%
Siemens
6ES7531-7QD00-0AB0

SIMATIC S7-1500 Analog input module AI 4xU/I/RTD/TC ST

Siemens 6ES7558-1AA00-0AB0 – SIMATIC S7-1500, TM MFP, Technology module Multi functional platform incl. 2 x Ethernet 2 x USB 1 x DPP…
Siemens
6ES7558-1AA00-0AB0

SIMATIC S7-1500, TM MFP, Technology module Multi functional…

Siemens 6ES7590-0BD00-0AA0 – SIMATIC S7-1500 / ET 200MP active backplane bus 4 slots for inserting S7-1500 I/O modules for hot swapping…
Siemens
6ES7590-0BD00-0AA0

SIMATIC S7-1500 / ET 200MP active backplane bus 4 slots for…

Siemens 6ES7590-0BH00-0AA0 – SIMATIC S7-1500 / ET 200MP active backplane bus 8 slots for inserting S7-1500 I/O modules for hot swapping…
Siemens
6ES7590-0BH00-0AA0

SIMATIC S7-1500 / ET 200MP active backplane bus 8 slots for…

Siemens 6ES7531-7QF00-0AB0Price and lead time confirmed within 1 business day
Request a Quote