What is the Siemens 6EP4143-8JB00-0XY0?
SITOP BAT8600 LiFePO4 battery module for UPS8600 48 V DC/358 Wh energy storage: maintenance-free lithium iron phosphate batteries
Specifications
General information
| Technical Product Detail Page | https://i.siemens.com/1P6EP4143-8JB00-0XY0 |
| product brand name | SITOP |
| product type designation | BAT8600 |
| product designation | Battery module 358 Wh |
| type of battery | maintenance-free LiFePO4 rechargeable battery |
| product version | Extension module/battery module |
output
| energy content of energy storage | 358 W·h |
| output current rated value | 20 A |
| output voltage at DC rated value | 48 V |
| design of the mains power cut bridging-connection | typ. 21 min at 960 W system load, typ. 42 min at 480 W system load (applies to new, fully charged battery module at ambient temperature 25°C) |
| number of parallel-switched equipment resources for increasing the power | 5 |
interfaces
| communication function | Yes |
protection and monitoring
| design of short-circuit protection | Blade-type fuse 40 A, 58 V DC |
| design of the overload protection | Valve control |
| display version for normal operation | 3-color LED for operating state module |
safety
| operating resource protection class | Class III |
| protection class IP | IP20 |
standards, specifications, approvals
| certificate of suitability — CE marking | Yes |
| certificate of suitability — UL approval | Yes; cULus (UL 61010-1 3rd Ed., UL 61010-2-201 2nd Ed.) |
| certificate of suitability — EAC approval | Yes |
| type of certification CB-certificate | Yes |
standards, specifications, approvals hazardous environments
| certificate of suitability — ATEX | No |
standards, specifications, approvals marine classification
| shipbuilding approval | Yes |
| Marine classification association — American Bureau of Shipping Europe Ltd. (ABS) | Yes |
| Marine classification association — Det Norske Veritas (DNV) | Yes |
standards, specifications, approvals Environmental Product Declaration
| Environmental Product Declaration | Yes |
| global warming potential [CO2 eq] — total | 65.113 kg |
| global warming potential [CO2 eq] — during manufacturing | 61.5 kg |
| global warming potential [CO2 eq] — during operation | 0.402 kg |
| global warming potential [CO2 eq] — after end of life | 1.172 kg |
ambient conditions
| ambient condition | For storage, mounting and operation of batteries, the relevant DIN/VDE regulations or country-specific regulations (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. |
| ambient temperature — during operation | -10 ... +50 °C |
| ambient temperature — during transport | -30 ... +70 °C |
| ambient temperature — during storage | -20 ... +35 °C |
service life
| service life of energy storage — typical | capacity falls to 80 % of original capacity (according to EUROBAT) |
| service life of energy storage — at 10 °C typical | 15 a |
| service life of energy storage — at 20 °C typical | 13 a |
| service life of energy storage — at 30 °C typical | 8 a |
| service life of energy storage — at 40 °C typical | 4 a |
| service life of energy storage — at 50 °C typical | 2 a |
| note | In addition to the storage temperature, additional factors, such as storage duration and charging status during storage, have a major impact on the potential service life. This means batteries should preferably be stored fully charged for short periods of time in a dry, cool and frost-proof (temperature range 0 to +20 °C) location. |
connection method
| type of electrical connection | Plug-in terminals with screwed connection |
| type of electrical connection — for UPS module | +, -: 2 plug-in terminals with 1 screwed connection each for 0.2 ... 10 mm² |
| type of electrical connection — for data cable | COM1, COM2: 2 plug-in terminals with 1 screwed connection each for 0.2 ... 2.5 mm² |
mechanical data
| width × height × depth of the enclosure | 322 × 187 × 110 mm |
| installation width × mounting height | 322 mm × 207 mm |
| required spacing — top | 20 mm |
| required spacing — bottom | 0 mm |
| required spacing — left | 0 mm |
| required spacing — right | 0 mm |
| fastening method | Keyhole mounting for hooking in to M4 screws |
| fastening method — DIN-rail mounting | No |
| fastening method — S7 rail mounting | No |
| fastening method — wall mounting | Yes |
| net weight | 7.1 kg |
| number of batteries | 4 |
accessories
| product component included | 2x blade-type fuse 40 A, 58 V DC |
further information internet links
| internet link — to website: Industry Mall | https://mall.industry.siemens.com |
| internet link — to web page: selection aid TIA Selection Tool | https://www.siemens.com/tstcloud |
| internet link — to web page: power supplies | https://siemens.com/sitop |
| internet link — to website: CAx-Download-Manager | https://www.siemens.com/cax |
| internet link — to website: Industry Online Support | https://support.industry.siemens.com |
additional information
| other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
security information
| security information | Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6EP4143-8JB00-0XY0: frequently asked questions
When can 6EP4143-8JB00-0XY0 be shipped?
6EP4143-8JB00-0XY0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6EP4143-8JB00-0XY0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6EP4143-8JB00-0XY0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6EP4143-8JB00-0XY0, subject to availability and destination.