
Pepperl Fuchs VBA-4E3A-G4-ZE/E2
AS-Interface sensor/actuator module
- MPN
- VBA-4E3A-G4-ZE/E2
- Category
- Modules
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs VBA-4E3A-G4-ZE/E2?
Degree of protection IP65
A/B node with extended addressing possibility for up to 62 nodes
Flat or round cable connection (via standardized EEMS base, not included with delivery)
Cable piercing method for flat cable
Inputs for 2- and 3-wire sensors
Power supply of outputs from the external auxiliary voltage
Power supply of inputs from the module
Function display for bus, ext. auxiliary voltage, inputs and outputs
LED indicator for overload on sensor supply
G4 module IP65, 4 inputs (PNP) and 3 electronic outputs
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 088725 |
| Node type | A/B node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| UL File Number | E223772 |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Indicators/operating means
| LED PWR/FAULT | dual LED green/red green: AS-Interface voltage red: communication error or address 0 green/red flashing: overload sensor supply or outputs |
| LED AUX | ext. auxiliary voltage UAUX ; LED green |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 3 LED yellow |
Electrical specifications
| Auxiliary voltage (output) | 24 V DC ± 15 % PELV UAUX |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 40 mA (without sensors) / max. 240 mA Ie |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply | from AS-Interface |
| Voltage | 21 ... 31 V |
| Current loading capacity | ≤ 180 mA (TB ≤ 40 °C), ≤ 140 mA (TB ≤ 60 °C), short-circuit protected |
| Input current | ≤ 9 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated) | ≤ 3 mA |
| 1 (attenuated) | ≥ 5 mA |
Output
| Number/Type | 3 electronic outputs, PNP, overload and short-circuit proof |
| Supply | from external auxiliary voltage UAUX |
| Voltage | ≥ (UAUX - 0.5 V) |
| Current | 4 A totalOUT 1, OUT 2: 2 A per outputOUT 3: 1.5 A |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 62026-2:2013 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2007 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005 |
Programming instructions
| Profile | S-7.A.0 |
| IO code | 7 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 0 |
| Data bits (function via AS-Interface) | InputOutput |
| D0 | IN1 OUT1 |
| D1 | IN2 OUT2 |
| D2 | IN3 OUT3 |
| D3 | IN4 - |
| Parameter bits (programmable via AS-i) | function |
| P0 | not used |
| P1 | not used |
| P2 | not used |
| P3 | not used |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , non-condensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP65 |
| Connection | cable piercing method or terminal compartment yellow flat cable/black flat cable or standard round cable inputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals |
| Material: Housing | PA 6 GF30 |
| Mass | 350 g |
| Tightening torque, housing screws | 0.8 Nm |
| Dimensions: Height | 71 mm |
| Dimensions: Width | 90 mm |
| Dimensions: Length | 102 mm |
| Mounting | DIN rail or screw mounting |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
VBA-4E3A-G4-ZE/E2: frequently asked questions
When can VBA-4E3A-G4-ZE/E2 be shipped?
VBA-4E3A-G4-ZE/E2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-4E3A-G4-ZE/E2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-4E3A-G4-ZE/E2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E3A-G4-ZE/E2, subject to availability and destination.
More Pepperl Fuchs parts











