Pepperl Fuchs VBA-4E3A-KE-ZEJ/E2L-LEN – AS-Interface sensor/actuator module. KE switch cabinet…
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBA-4E3A-KE-ZEJ/E2L-LEN be shipped?
VBA-4E3A-KE-ZEJ/E2L-LEN is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-4E3A-KE-ZEJ/E2L-LEN in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-4E3A-KE-ZEJ/E2L-LEN and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E3A-KE-ZEJ/E2L-LEN, subject to availability and destination.
AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs and 3 outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.1. UL File Number: E223772. LED FAULT: Error display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs. LED INT: Internal input supply active; LED green. LED PWR: AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 3 LED yellow/redyellow: Output activered: Output overload or lead breakage. Auxiliary voltage (output): 20 ... 30 V DC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 35 mA (without sensors) / max. 190 mA. Protection class: III. Surge protection: UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface. Voltage: 21 ... 31 V DC. Current loading capacity: ≤ 150 mA, overload and short-circuit protected. Input current: ≤ 9 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 3 mA1 (attenuated)≥ 5 mA: . 0 (unattenuated): ≤ 3 mA. 1 (attenuated): ≥ 5 mA. Signal delay: < 1 ms (input/AS-Interface). Number/Type: 3 electronic outputs, PNP, overload and short-circuit proof. Supply: from external auxiliary voltage UAUX. Voltage: ≥ (UAUX - 0.5 V). Current: O1 max. 3 A, O2/O3 max. 1.5 A, total 6 A (TB ≤ 40 °C)O1 max. 2 A, O2/O3 max. 1 A, total 4 A (TB ≤ 60 °C). Usage category: DC-13. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2004. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013. Profile: S-7.A.0. IO code: 7. ID code: A. ID1 code: 7. ID2 code: 0. Data bits (function via AS-Interface): InputOutput. D0 IN1 O1D1 IN2 O2D2 IN3 O3D3 IN4 -: . D0: IN1 O1. D1: IN2 O2. D2: IN3 O3. D3: IN4 -. Parameter bits (programmable via AS-i): function. P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings)P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings)P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings)P3not used: . P0: Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings). P1: Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings). P2: Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings). P3: not used. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Degree of protection: IP20. Connection: removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 150 g. Dimensions: . Height99 mmWidth22.5 mmLength102 mm: . Height: 99 mm. Width: 22.5 mm. Length: 102 mm. Mounting: DIN mounting rail. Tightening torque of clamping screws: 0.5 Nm ... 0.6 Nm
Specifications
General specifications
| Node type | A/B node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| UL File Number | E223772 |
Indicators/operating means
| LED FAULT | Error display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs |
| LED INT | Internal input supply active; LED green |
| LED PWR | AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 3 LED yellow/redyellow: Output activered: Output overload or lead breakage |
Electrical specifications
| Auxiliary voltage (output) | 20 ... 30 V DC PELV UAUX |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 35 mA (without sensors) / max. 190 mA Ie |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply | from AS-Interface |
| Voltage | 21 ... 31 V DC |
| Current loading capacity | ≤ 150 mA, overload and short-circuit protected |
| Input current | ≤ 9 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 3 mA1 (attenuated)≥ 5 mA | 0 (unattenuated) |
| 0 (unattenuated) | ≤ 3 mA |
| 1 (attenuated) | ≥ 5 mA |
| Signal delay | < 1 ms (input/AS-Interface) |
Output
| Number/Type | 3 electronic outputs, PNP, overload and short-circuit proof |
| Supply | from external auxiliary voltage UAUX |
| Voltage | ≥ (UAUX - 0.5 V) |
| Current | O1 max. 3 A, O2/O3 max. 1.5 A, total 6 A (TB ≤ 40 °C)O1 max. 2 A, O2/O3 max. 1 A, total 4 A (TB ≤ 60 °C) |
| Usage category | DC-13 |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2004 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Programming instructions
| Profile | S-7.A.0 |
| IO code | 7 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 0 |
| Data bits (function via AS-Interface) | InputOutput |
| D0 IN1 O1D1 IN2 O2D2 IN3 O3D3 IN4 - | D0 |
| D0 | IN1 O1 |
| D1 | IN2 O2 |
| D2 | IN3 O3 |
| D3 | IN4 - |
| Parameter bits (programmable via AS-i) | function |
| P0Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings)P1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings)P2Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings)P3not used | P0 |
| P0 | Communication monitoringP0 = 0 monitoring = off, the outputs maintain the status if communication failsP0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) |
| P1 | Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) |
| P2 | Lead breakage outputsP2 = 0 lead breakage onP2 = 1 lead breakage off (default settings) |
| P3 | not used |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
| Material | |
| HousingPA 66-FR | Housing |
| Housing | PA 66-FR |
| Mass | 150 g |
| Dimensions | |
| Height99 mmWidth22.5 mmLength102 mm | Height |
| Height | 99 mm |
| Width | 22.5 mm |
| Length | 102 mm |
| Mounting | DIN mounting rail |
| Tightening torque of clamping screws | 0.5 Nm ... 0.6 Nm |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs VBA-4E3A-G20-ZEL/E2L-P11 – ASi I/O Module. G20 module with AS-Interface for digital…
Available on requestPepperl Fuchs VBA-4E3A-G20-ZEL/E2L-P5 – ASi I/O Module. G20 module with AS-Interface for digital…
Available on requestPepperl Fuchs VBA-4E3A-G20-ZEL/M1L-P2 – ASi Motor Roller Module. G20 MDR module with AS-Interface…
Available on requestPepperl Fuchs VBA-4E3A-G4-ZE/E2 – AS-Interface sensor/actuator module. G4 module IP65
Available on requestPepperl Fuchs VBA-4E3A-KE-ZEJQ/E2L – AS-Interface sensor/actuator module. KE switch cabinet…
Available on requestPepperl Fuchs VBA-4E3A-KE-ZE/R – AS-Interface sensor/actuator module. KE switch cabinet…
Available on requestPepperl Fuchs VBA-4E4A-CB1-ZEJ/E2J – AS-Interface printed circuit board module. Printed circuit…
Available on requestPepperl Fuchs VBA-4E4A-CB1-ZEJ/E2J-FL – AS-Interface printed circuit board module. Printed circuit…