Pepperl Fuchs VBA-4E3A-KE-ZE/R

AS-Interface sensor/actuator module

MPN
VBA-4E3A-KE-ZE/R
Category
Modules
Price and lead time confirmed within 1 business day

Discontinued by Pepperl Fuchs — we can still source the original VBA-4E3A-KE-ZE/R (new, used or refurbished, subject to availability). Request a quote below.

Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs VBA-4E3A-KE-ZE/R?

A/B node with extended addressing possibility for up to 62 nodes

Housing with removable terminals

Communication monitoring

Inputs for 2- and 3-wire sensors

Isolated relay output

Addressing jack

Supply of inputs external or from the module, as required

Function display for bus, internal input supply, inputs and outputs

KE switch cabinet module, 4 inputs (PNP) and 3 relay outputs

Pepperl+Fuchs has archived the VBA-4E3A-KE-ZE/R: it is no longer part of the current range. PartnerPLC sources discontinued Pepperl+Fuchs parts on the surplus market for maintenance and repair of existing installations — request a quote for availability, condition, price and lead time.

Specifications

General specifications

Order code (Pepperl+Fuchs part number)114307
Node typeA/B node
AS-Interface specificationV2.1
Required gateway specification≥ V2.1
ProfileS-7.A.0
IO code7
ID codeA
ID1 code7
ID2 code0
UL File NumberE106378
LifecycleDiscontinued — archived by Pepperl+Fuchs

Indicators/operating means

LED FAULTFault display; Red LED red: Communication fault or address is 0 red, flashing: Overload, internal input supply
LED INTInternal input supply active; LED green
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 4 LED yellow
LED OUTSwitching state (output); 3 LED yellow

Electrical specifications

Auxiliary voltage (input)12 ... 30 V DC PELV UEXT
Rated operating voltage26.5 ... 31.6 V from AS-Interface Ue
Rated operating current≤ 35 mA (without sensors) / max. 235 mA Ie
Surge protectionO1 ... O3: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV)

Input

Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)
Voltage21 ... 31 V DC (INT)
Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT)
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 2 mA
1 (attenuated)≥ 4 mA
Signal delay< 2 ms (input/AS-Interface)
Signal frequency≤ 250 Hz

Output

Number/Type3 relay outputs, normally open
Supplynone
Nominal load: Per contactmax. 2 A / 30 V DC; 2 A / 250 V AC
Nominal load: Per module6 A
Minimum load: Per contact10 mA / 5 V DC
Short-circuit-proofContact: 500 A / 40 ms
Switching off power500 VA
Switching delay< 10 ms (AS-Interface/contact)
Usage categoryDC-13 and AC-14
Switching frequency< 20 Hz (without load) < 0.1 Hz (nominal load) f
Switching: Mechanical30 x 106
Switching: Electrical1 x 106 switching cycles (40 V DC, 2 A, ohmic) 0.5 x 106 switching cycles (253 V AC, 2 A, cos φ = 1) 0.45 x 106 switching cycles (253 V AC, 2 A, cos φ = 0.7)

Galvanic isolation

Input/OutputIN1 ... IN4 to O1 ... O3: safe isolation acc. to EN 60947-1,rated insulation voltage 278 V AC
Input/AS-Interfacenone
Output/OutputO1 to O2, O3: safe isolation according to EN 60947-1,rated insulation voltage 278 V ACO2 to O3: basic insulation according to EN 60947-1,rated insulation voltage 278 V AC
Output/AS-Interfacesafe isolation acc. to EN 60947-1,rated insulation voltage 278 V AC

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Low voltage: Directive 73/23/EECEN 60947-1:2007

Standard conformity

Galvanic isolationEN 60947-1
Electromagnetic compatibilityNAMUR NE 21: 1998-08
Degree of protectionEN 60529:2000
Pollution degreeEN 60947-5-1
InputEN 61131-2:2004
Usage categoryEN 60947-5-1
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005

Ambient conditions

Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution degree2

Mechanical specifications

Degree of protectionIP20
Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Material: HousingPA 66-FR
Mass170 g
Dimensions: Height99 mm
Dimensions: Width22.5 mm
Dimensions: Length102 mm
MountingDIN mounting rail
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm

VBA-4E3A-KE-ZE/R: frequently asked questions

Can I still buy the VBA-4E3A-KE-ZE/R now that it is discontinued?

Yes. Pepperl Fuchs has discontinued the VBA-4E3A-KE-ZE/R, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.

When can VBA-4E3A-KE-ZE/R be shipped?

VBA-4E3A-KE-ZE/R is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VBA-4E3A-KE-ZE/R in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VBA-4E3A-KE-ZE/R and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E3A-KE-ZE/R, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs VBA-4E3A-KE-ZE/RPrice and lead time confirmed within 1 business day
Request a Quote