Pepperl Fuchs VAA-4E4A-KE-ZE/R
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VAA-4E4A-KE-ZE/R be shipped?
VAA-4E4A-KE-ZE/R is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VAA-4E4A-KE-ZE/R in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VAA-4E4A-KE-ZE/R and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-4E4A-KE-ZE/R, subject to availability and destination.
AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs (PNP) and 4 relay outputs. Node type: Standard node. AS-Interface specification: V2.1. Required gateway specification: ≥ V2.0. Profile: S-7.0. IO code7ID code0ID1 codeFID2 codeE: . IO code: 7. ID code: 0. ID1 code: F. ID2 code: E. UL File Number: E106378. LED FAULT: Fault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply. LED INT: Internal input supply active; LED green. LED PWR: AS-Interface voltage; LED green. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 4 LED yellow. Auxiliary voltage (input): 12 ... 30 V DC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 35 mA (no sensors)/max. 210 mA. Surge protection: O1 ... O4: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT). Voltage: 21 ... 31 V DC (INT). Current loading capacity: ≤ 150 mA, overload- and short-circuit protected (INT). Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Signal delay: < 2 ms (input/AS-Interface). Number/Type: 4 relay outputs, normally open. Supply: none. Nominal load: . Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V ACPer module8 A: . Per contact: 2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC. Per module: 8 A. Control circuit: ≤ 8 mA per relay (from AS-Interface). Switching delay: < 10 ms (AS-Interface/contact). Usage category: DC-13 and AC-14. Switching: . Mechanical5 x 106Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4): . Mechanical: 5 x 106. Electrical: 0.2 x 106 (250 V AC, 2 A, cos φ = 0.4). Input/Output: safe isolation, rated insulation voltage 300 V AC. Input/AS-Interface: Switch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC. Output/Output: basic insulation, rated insulation voltage 300 V AC. Output/AS-Interface: safe isolation, rated insulation voltage 300 V AC. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61326:2003: . Directive 2014/30/EU: EN 62026-2:2013 EN 61326:2003. Low voltage: . Directive 73/23/EECEN 60947-1:2007: . Directive 73/23/EEC: EN 60947-1:2007. Galvanic isolation: EN 60664-1:2007. Electromagnetic compatibility: NAMUR NE 21: 1998-08. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. AS-Interface: EN 62026-2:2013. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Degree of protection: IP20. Connection: removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 170 g. Dimensions: . Height99 mmWidth22.5 mmLength102 mm: . Height: 99 mm. Width: 22.5 mm. Length: 102 mm. Mounting: DIN mounting rail. Tightening torque of clamping screws: 0.5 Nm ... 0.6 Nm
Specifications
General specifications
| Node type | Standard node |
| AS-Interface specification | V2.1 |
| Required gateway specification | ≥ V2.0 |
| Profile | S-7.0 |
| IO code7ID code0ID1 codeFID2 codeE | IO code |
| IO code | 7 |
| ID code | 0 |
| ID1 code | F |
| ID2 code | E |
| UL File Number | E106378 |
Indicators/operating means
| LED FAULT | Fault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply |
| LED INT | Internal input supply active; LED green |
| LED PWR | AS-Interface voltage; LED green |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 4 LED yellow |
Electrical specifications
| Auxiliary voltage (input) | 12 ... 30 V DC PELV UEXT |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 35 mA (no sensors)/max. 210 mA Ie |
| Surge protection | O1 ... O4: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
| Voltage | 21 ... 31 V DC (INT) |
| Current loading capacity | ≤ 150 mA, overload- and short-circuit protected (INT) |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA | 0 (unattenuated) |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
| Signal delay | < 2 ms (input/AS-Interface) |
Output
| Number/Type | 4 relay outputs, normally open |
| Supply | none |
| Nominal load | |
| Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V ACPer module8 A | Per contact |
| Per contact | 2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC |
| Per module | 8 A |
| Control circuit | ≤ 8 mA per relay (from AS-Interface) |
| Switching delay | < 10 ms (AS-Interface/contact) |
| Usage category | DC-13 and AC-14 |
| Switching | |
| Mechanical5 x 106Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4) | Mechanical |
| Mechanical | 5 x 106 |
| Electrical | 0.2 x 106 (250 V AC, 2 A, cos φ = 0.4) |
Galvanic isolation
| Input/Output | safe isolation, rated insulation voltage 300 V AC |
| Input/AS-Interface | Switch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC |
| Output/Output | basic insulation, rated insulation voltage 300 V AC |
| Output/AS-Interface | safe isolation, rated insulation voltage 300 V AC |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 EN 61326:2003 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61326:2003 |
| Low voltage | |
| Directive 73/23/EECEN 60947-1:2007 | Directive 73/23/EEC |
| Directive 73/23/EEC | EN 60947-1:2007 |
Standard conformity
| Galvanic isolation | EN 60664-1:2007 |
| Electromagnetic compatibility | NAMUR NE 21: 1998-08 |
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| AS-Interface | EN 62026-2:2013 |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
| Material | |
| HousingPA 66-FR | Housing |
| Housing | PA 66-FR |
| Mass | 170 g |
| Dimensions | |
| Height99 mmWidth22.5 mmLength102 mm | Height |
| Height | 99 mm |
| Width | 22.5 mm |
| Length | 102 mm |
| Mounting | DIN mounting rail |
| Tightening torque of clamping screws | 0.5 Nm ... 0.6 Nm |