Pepperl Fuchs KFD2-VR2-Ex1.50M

Voltage Repeater

MPN
KFD2-VR2-Ex1.50M
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs KFD2-VR2-Ex1.50M?

1-channel isolated barrier

24 V DC supply (Power Rail)

Voltage input 0 mV ... ± 50 mV

Voltage output 0 mV ... ± 50 mV

Selectable up/downscale sensor breakage detection

1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... ± 50 mV, Voltage output 0 mV ... ± 50 mV, Selectable up/downscale sensor breakage detection, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Rated voltage: 19 ... 30 V DC, Signal: 1 x -50 ... 50 mV, Signal: 1 x -50 ... 50 mV, Cut-off frequency: 350 Hz (-3 dB)

Specifications

General specifications

Order code (Pepperl+Fuchs part number)181951
Signal typeAnalog input
LifecycleActive (current Pepperl+Fuchs product)

Supply

ConnectionPower Rail or terminals 14+, 15-
Rated voltage19 ... 30 V DC Ur
Ripplewithin the supply tolerance
Rated current≤ 11 mA Ir
Power dissipation/power consumption0.3 W max.

Input

Connection sidefield side
Connectionterminals 4+, 5-
Input resistancemin. 20 MΩ
Transmission range-50 ... 50 mV
Offset voltage/current≤ 5 µV / ≤ 5 nA
Line fault detection100 nA

Output

Connection sidecontrol side
Connectionterminals 7+, 8-
Voltage-50 ... 50 mV
LoadAccuracy figures for infinite load impedance. Additional 0.03 % of span for a load resistance of 10 kΩ
Fault signalsensor breakage: > +100 mV (upscale), < -100 mV (downscale)
Output resistancemax. 3 Ω

Transfer characteristics

Cut-off frequency350 Hz (-3 dB)
Deviation: After calibrationat 20 °C (68 °F): ± 3 µV up to ± 10 mV/± 0.03 % of the span up to +50 mV/± 0.05 % of the span up to -50 mV
Deviation: Influence of ambient temperature± 1 µV/K (typical ± 0.25 µV/K)
Absolute< 0.25 K at 30 V voltage supply
Rise time≤ 1 ms

Galvanic isolation

Output/power supplyfunctional insulation, rated insulation voltage 50 V AC

Indicators/settings

Display elementsLED
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 125 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Height119 mm
Width20 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateBASEEFA 06 ATEX 0040
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Voltage5.5 V DC Uo
Current2.4 mA Io
Power3.3 mW Po
Supply: Maximum safe voltage250 V (Attention! The rated voltage can be lower.) Um
CertificateBASEEFA 09 ATEX 0219X
MarkingII 3G Ex ec IIC T4 Gc
Galvanic isolation: Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic isolation: Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN IEC 60079-7:2015+A1:2018 , EN 60079-11:2012

International approvals

UL approvalE106378
Control drawing116-0334 (cULus)
IECEx approval: IECEx certificateIECEx BAS 06.0011 IECEx BAS 09.0103X
IECEx approval: IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFD2-VR2-Ex1.50M: frequently asked questions

When can KFD2-VR2-Ex1.50M be shipped?

KFD2-VR2-Ex1.50M is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD2-VR2-Ex1.50M in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD2-VR2-Ex1.50M and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-VR2-Ex1.50M, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFU8-CRG2-1.D – Transmitter Power Supply
Pepperl Fuchs
KFU8-CRG2-1.D

Transmitter Power Supply

Pepperl Fuchs KFD2-VR2-Ex1.50MPrice and lead time confirmed within 1 business day
Request a Quote