Pepperl Fuchs KFD2-VR4-Ex1.26
Voltage Repeater
- MPN
- KFD2-VR4-Ex1.26
- Category
- K-System (DIN Rail Mounting)
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs KFD2-VR4-Ex1.26?
1-channel isolated barrier
24 V DC supply (Power Rail)
Voltage input 0 V ... -20 V
Vibration sensor inputs
Voltage/current field supply
Voltage output 0 V ... -20 V
Up to SIL 2 acc. to IEC/EN 61508
1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltage output 0 V ... -20 V, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Signal: 1 x -20 ... 0 V, Signal: 1 x -20 ... 0 V, Cut-off frequency: 10 kHz (-0,1 dB) , 20 kHz (-1 dB)
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 70107327 |
| Signal type | Analog input |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
Supply
| Connection | Power Rail or terminals 11+, 12- |
| Rated voltage | 19 ... 30 V DC Ur |
| Ripple | within the supply tolerance |
| Power dissipation | ≤ 1.2 W |
| Power consumption | ≤ 1.6 W |
Input
| Connection side | field side |
| Connection | terminals 4 (common), 1, 3 and 5 (supply -), 2 and 6 (signal -) |
| Input resistance | 10 kΩ terminals 4 (common), 6-/2- |
| Output current | terminals 4 (common), 5-: > 10 mA at -21 V or > 20 mA at -18 V terminals 4 (common), 1-: 5.3 mA ±0.4 mA at -10 V terminals 4 (common), 3-: 3.6 mA ±0.7 mA at -10 V, 20 °C (68 °F) |
| Transmission range | -20 ... 0 V |
Output
| Connection side | control side |
| Connection | terminals 7-, 8+ |
| Voltage | -20 ... 0 V |
| Load | ≥ 9 kΩ (3-wire sensor), ≥ 2 kΩ (2-wire sensor) |
| Output resistance | 24 Ω typ., 27 Ω maximum Since this is much less than the end-to-end resistance of a zener barrier, it may be necessary to specify a monitor intended for use without a barrier. Please follow the advice of the monitor manufacturer. |
Transfer characteristics
| Cut-off frequency | 10 kHz (-0,1 dB) 20 kHz (-1 dB) |
| Deviation | DC transfer error (with 10 kΩ load) < 10mV |
| After calibration | additional error with AC superimposed is ±5 mV at 20 °C (68 °F) at any point within the span, provided that the alternating component of the input voltage is not excessive, e. g. - square waves (0 ... 20 kHz): 5 Vpp - sine waves (0 ... 20 kHz): the full span of 20 Vpp (= 100 g peak acceleration at 100 mV/g) is acceptable. |
| Influence of ambient temperature | (< 100 ppm of span)/K at any point within the span |
| Time delay relative to input | 7.1 ±0.3 µs |
| Ripple | in 200 kHz bandwidth < 20 mVrms in 20 kHz bandwidth < 3 mVrms |
Galvanic isolation
| Output/power supply | functional insulation, rated insulation voltage 50 V AC |
Indicators/settings
| Display elements | LED |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 EN IEC 61326-3-2:2018 |
| Degree of protection | IEC 60529 |
| Protection against electrical shock | UL 61010-1 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 125 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | BAS 02 ATEX 7206 |
| Marking | II (1)G [Ex ia Ga] IIC , [exsign] II (1)D [Ex ia Da] IIIC |
| Input | Ex ia Ga, Ex ia Da |
| Voltage | -26.4 V Uo |
| Current | 90 mA Io |
| Power | 570 mW Po |
| Supply: Maximum safe voltage | 253 V (Attention! The rated voltage can be lower.) Um |
| Output: Maximum safe voltage | 253 V (Attention! The rated voltage is lower.) Um |
| EU-type examination certificate | DMT 01 ATEX E 133 |
| Marking | I (M1) [Ex ia] I |
| Certificate | TÜV 99 ATEX 1499 X |
| Marking | II 3G Ex nA II T4 |
| Galvanic isolation: Input/Output | safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V |
| Galvanic isolation: Input/power supply | safe galvanic isolation acc. to IEC 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000 |
International approvals
| UL approval: Control drawing | 116-0316 (cULus) |
| IECEx approval: IECEx certificate | IECEx BAS 05.0078 IECEx BAS 10.0085X |
| IECEx approval: IECEx marking | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex nA II T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (10)
- South Africa MASC (MASC M/17-0784)
- United Arab Emirates SGS Gulf Limited ECASEx (25-11-170189/E25-11-177130/NB0002 (Vietnam))
- United Arab Emirates SGS Gulf Limited ECASEx (25-11-170190/E25-11-177129/NB0002)
- EU Declaration of Conformity (Pepperl+Fuchs)
- China SITIIAS CCC Ex Certificate (2025322316006928 (Vietnam))
- China SITIIAS CCC Ex Certificate (2020322316001400 (Singapore))
- Australia Test Safe (ANZEx 17.3006X)
- Canada UL Hazardous Location UL E106378 cUL (CoC UL-CA-L106378-47761-13219002-2)
- USA UL Hazardous Location UL UL E106378 (CoC UL-US-L106378-47731-13219002-2)
- Japan TIIS (TC22384)
KFD2-VR4-Ex1.26: frequently asked questions
When can KFD2-VR4-Ex1.26 be shipped?
KFD2-VR4-Ex1.26 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-VR4-Ex1.26 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-VR4-Ex1.26 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-VR4-Ex1.26, subject to availability and destination.
More Pepperl Fuchs parts