Pepperl Fuchs ICA-16IO-G20-IO-P16
I/O hub IO-Link
- MPN
- ICA-16IO-G20-IO-P16
- Category
- IO-Link Infrastructure
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs ICA-16IO-G20-IO-P16?
16 digital inputs/outputs can be configured
Configuration and control via IO-Link
IO-Link Class A
LED for switching state and fault indication
Supply from IO-Link
IO-Link 1.1.3
G20 IO-Link I/O Hub for 16 freely configurable digital inputs/outputs
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 70149090 |
| UL File Number | E223772 |
| MTBF | 149 a |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Indicators/operating means
| LED green | : IO1..8 / IO9..16 bank indication |
| LED yellow/red | IO1 ... IO16: inputs/outputs status, IO-Link status |
Electrical specifications
| Operating voltage | 18 ... 30 V DC, PELV Current limitation of the supply max. 4 A UB |
| No-load supply current | ≤ 25 mA I0 |
| Operating current | max. 4 A IB |
Interface
| Interface type | IO-Link |
| IO-Link revision | 1.1 |
| Device profile | Identification and Diagnosis - I&D Firmware update |
| Process data | Inputs 3 Byte - Input signals 16 Bit - diagnosis signals 5 Bit Outputs 2 Byte - Output signals 16 Bit |
| Vendor ID | 1 (0x0001) |
| Device ID | 985345 (0x0F0901) |
| Data transfer rate | COM3 (230.4 kbits/s) |
| Min. cycle time | 1 ms |
| SIO mode support | no |
| Compatible master port type | Class A |
Input
| Number/Type | 16 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO16) |
| Supply | from IO-Link |
| Current loading capacity | 200 mA , overload and short-circuit protected |
| Input current | ≤ 5 mA (limited internally) |
| Switching point | Type 3 according to IEC 61131-2 |
Output
| Number/Type | 16 electronic outputs, PNP (IO1 … IO16), overload-proof and short-circuit-proof |
| Supply | from IO-Link |
| Voltage | ≥ (UB - 1.5 V) |
| Current | 200 mA per output |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 EN 55011:2016 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Input | EN 61131-2:2007 |
| Communication interface | IEC 61131-9:2013 / IO-Link V1.1.3 |
| Emitted interference | EN 61000-6-4:2007 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006 |
Approvals and certificates
| UL approval | UL 61010-1, UL 61010-2-201 Load specification DC General Use / DC Pilot Duty Degree of protection not tested by UL; tested by Pepperl+Fuchs SE |
Ambient conditions
| Ambient temperature | -30 ... 70 °C (-22 ... 158 °F) |
| Storage temperature | -30 ... 85 °C (-22 ... 185 °F) |
| Relative humidity | 85 % non-condensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 5000 m above MSL |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions,1000 shocks |
| Vibration resistance | 0.35 mm / 5 g 5 ... 500 Hz |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP67 according to EN 60529 |
| Connection | IO-Link: M12 round plug connector in accordance with EN 61076-2-101, LM type (4-pin, connector contacts, screw-locking, A-coded) Female connector: LF type or similarIO: M8 round plug connector in accordance with EN 61076-2-104, LF type (4-pin, bushing contacts, screw-locking, A-coded)Mating connector: LM type or similar |
| Mass | 310 g |
| Dimensions: Height | 27.5 mm |
| Dimensions: Width | 131.5 mm |
| Dimensions: Length | 54 mm |
| Mounting | 2 clips with ∅ 8 mm drill hole The module must be secured to a solid, continuous surface using the two lugs |
| Cable length | 1 m (IO-Link)0.2 m (IO1/2, IO15/16), 0.3 m (IO3/4, IO13/14)0.4 m (IO5/6, IO11/12); 0.5 m (IO7/8, IO9/10)max. 10 m |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
ICA-16IO-G20-IO-P16: frequently asked questions
When can ICA-16IO-G20-IO-P16 be shipped?
ICA-16IO-G20-IO-P16 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ICA-16IO-G20-IO-P16 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ICA-16IO-G20-IO-P16 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ICA-16IO-G20-IO-P16, subject to availability and destination.