Quick facts
| Availability | Confirmed on request |
| Category | Digital outputs |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can X90PO210.08-00 be shipped?
X90PO210.08-00 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X90PO210.08-00 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X90PO210.08-00 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X90PO210.08-00, subject to availability and destination.
9 to 32 VDC8 PWM outputs4 A per channelCurrent measurementCentral cutoffX2X LinkThe PWM option board offers 8 additional analog outputs that can also be used as digital inputs/outputs. Communication to the mainboard is implemented using X2X Link. In addition, the PWM option board provides current measurement for each channel.
Specifications
Specifications
| I/O module | 8 digital inputs/outputs 9 to 32 VDC for 1-wire connections |
| B&R ID code | 0xEBC2 |
| Status indicators | - |
| Diagnostic outputs | In the application using current measurement |
| Power consumption | 0.91 W |
| Digital - Digital | No |
| UN ECE-R10 | Yes |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| Quantity | 0 to 8, depends on the use of multifunction inputs/outputs |
| Functions | 4 A nominal current / channel PWM frequency 15 Hz to 1 kHz, digital input/output, sink/source circuit - configurable per channel, configurable software input filter, configurable switch-on/switch-off ramp, integrated output protection |
| Input voltage | 9 to 32 VDC |
| Input current at 24 VDC | Typ. 2.7 mA |
| Input circuit | Sink/Source, configurable |
| Hardware | 100 µs |
| Software | Default 1 ms, configurable between 0 and 25 ms in 0.1 ms increments |
| Input resistance | Typ. 9 kΩ |
| Switching threshold | 45% supply voltage |
| Nominal voltage | 12/24 VDC |
| Supply voltage (permissible range) | 9 to 32 VDC |
| Nominal current | 4 A |
| Summation current | 16 A |
| PWM frequency | 15 Hz to 1 kHz |
| Duty cycle | 0 to 100% in 0.1% steps, resolution <50 μs |
| Output circuit | Sink/Source |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads |
| Variant | Current-sourcing/Current-sinking FET |
| Diagnostic status | Output monitoring with 1 ms delay |
| Leakage current when the output is switched off | Max. 50 µA |
| Residual voltage | <0.1 V at 4 A nominal current |
| Peak short-circuit current | 50 A (max. 0.2 ms) |
| Current measurement range | ±10 A |
| Conversion time | 40 μs |
| Resolution | 12-bit (6 mA) |
| Data type | INT 0x8001 to 0x7FFF |
| Current | 1 LSB = 305 μA |
| Accuracy | ±0.5% ±50 mA |
| Temperature drift | ±0.02%/°C ±1 mA/°C |
| Common mode error | ±3 mA/V |
| Any | Yes |
| Degree of protection per EN 60529 | Up to IP69K |
| Horizontal mounting orientation | -40 to 85°C housing surface |
| Vertical mounting orientation | -40 to 85°C housing surface |
| Storage | 5 to 100%, condensing |
| Transport | 5 to 100%, condensing |
| Operation | 5 to 100%, condensing |
| Width | 47 mm |
| Length | 95 mm |
More B&R parts
UsedB&R 5C5001.01 IPC 5000 5D5500.06 Used
UsedB&R 5PC720.1505-K07 - 5P62:0A-03 Used