B&R X20DO4322

I/O module, 4 digital outputs 24 VDC for 3-wire connections

MPN
X20DO4322
€51.94excl. VAT & shipping
In stock — 2 available·Ships within 1 business day
Choose condition
Need a larger quantity or a formal quote?
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the B&R X20DO4322?

4 digital outputs

Source connection

3-wire connections

24 VDC and GND for actuator supply

Integrated output protection

OSP mode

This module is equipped with 4 outputs with 3-wire connections as well as 24 VDC and GND for the actuator power supply. The outputs are designed for a source circuit.

Specifications

Short description

I/O module4 digital outputs 24 VDC for 3-wire connections

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – OutputsYes, using LED status indicator and software (output error status)
Power consumption – Bus0.16 W
Power consumption – Internal I/O0.49 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – DNVTemperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
Certifications – CCSYes
Certifications – LRENV1
Certifications – KRYes
Certifications – ABSYes
Certifications – BVEC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck
Certifications – KCYes
B&R ID code0x1B97
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]Mechanical and electrical configuration" in the X20 system user's manual.">+0.21 (note: Number of outputs x R DS(on) x Nominal output current 2 . For a calculation example, see section)

Digital outputs

Switching delay – 0 → 1<300 µs (note: At loads ≤ 1 kΩ)
Switching delay – 1 → 0<300 µs (note: At loads ≤ 1 kΩ)
Switching frequency – Resistive loadMax. 500 Hz (note: At loads ≤ 1 kΩ)
Switching frequency – Inductive loadSee section "Switching inductive loads".
VariantCurrent-sourcing FET
Nominal voltage24 VDC
Switching voltage24 VDC -15% / +20%
Nominal output current0.5 A
Total nominal current2 A
Connection type3-wire connections
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current"); Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")
Actuator power supply0.5 A in total for output-independent actuator power supply
Diagnostic statusOutput monitoring with 10 ms delay
Leakage current when the output is switched off5 µA
R DS(on)210 mΩ
Peak short-circuit current<12 A
Switch-on in the event of overload shutdown or short-circuit shutdownApprox. 10 ms (depends on the module temperature)
Braking voltage when switching off inductive loadsTyp. 50 VDC
Insulation voltage between channel and bus500 V eff

Actuator power supply

Power consumption – Actuator power supplyMax. 12 W (note: The power consumption of the sensors connected to the module is not permitted to exceed 12 W.)
VoltageModule power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 500 mAMax. 2 V
Short-circuit proofYes

Electrical properties

Electrical isolationChannel isolated from bus; Channel not isolated from channel and I/O power supply

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C
Temperature – Vertical mounting orientation-25 to 50°C
Temperature – Derating-
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (16)

X20DO4322: frequently asked questions

When can X20DO4322 be shipped?

X20DO4322 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20DO4322 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20DO4322 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20DO4322, subject to availability and destination.

More B&R parts

B&R X20DO2623 – I/O module, 2 digital SSR outputs 100 to 240 VAC for 3-wire…
B&R
X20DO2623

I/O module, 2 digital SSR outputs 100 to 240 VAC for 3-wire…

B&R X20DO2633 – I/O module, 2 digital outputs 48 to 240 VAC for 3-wire…
B&R
X20DO2633

I/O module, 2 digital outputs 48 to 240 VAC for 3-wire…

B&R X20DO2649 – I/O module, 2 digital outputs 30 VDC / 240 VAC
B&R
X20DO2649

I/O module, 2 digital outputs 30 VDC / 240 VAC

B&R X20DO4321 – I/O module, 4 digital outputs 24 VDC for 3-wire connections
B&R
X20DO4321

I/O module, 4 digital outputs 24 VDC for 3-wire connections

B&R X20DO4331 – I/O module, 4 digital outputs 24 VDC for 3-wire connections
B&R
X20DO4331

I/O module, 4 digital outputs 24 VDC for 3-wire connections

B&R X20DO4332 – I/O module, 4 digital outputs 24 VDC for 3-wire connections
B&R
X20DO4332

I/O module, 4 digital outputs 24 VDC for 3-wire connections

B&R X20DO4332-1 – I/O module, 4 digital outputs 24 VDC for 3-wire connections
B&R
X20DO4332-1

I/O module, 4 digital outputs 24 VDC for 3-wire connections

B&R X20DO4529 – I/O module, 4 digital outputs 30 VDC / 115 VAC
B&R
X20DO4529

I/O module, 4 digital outputs 30 VDC / 115 VAC