B&R X20DO4529
I/O module, 4 digital outputs 30 VDC / 115 VAC
- MPN
- X20DO4529
- Category
- Digital outputs
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
What is the B&R X20DO4529?
4 digital outputs
Relay module for 115 VAC
4 change over contacts
Single-channel isolated outputs
This module is equipped with 4 relay outputs with changeover contacts for 115 VAC. The outputs are single-channel isolated.
Specifications
Short description
| I/O module | 4 digital outputs 30 VDC / 115 VAC, outputs single-channel isolated |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Outputs | Yes, using LED status indicator |
| Power consumption – Bus | 0.8 W |
| Power consumption – Internal I/O | - |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| Certifications – KC | Yes |
| B&R ID code | 0x20D9 |
| Status indicators | I/O function per channel, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W]Mechanical and electrical configuration" in the X20 system user's manual."> | +0.3 (note: Number of outputs x Contact resistance x Nominal output current 2 . For a calculation example, see section) |
Digital outputs
| Switching delay – 0 → 1 | ≤4 ms |
| Switching delay – 1 → 0 | ≤4 ms |
| Insulation voltages – Channel - Bus | Tested at 1500 VAC |
| Insulation voltages – Channel - Channel | Tested at 1000 VAC |
| Service life – ElectricalElectrical service life"."> | Min. 100 x 10³ ops. (note: With resistive load. See also section) |
| Service life – Mechanical | Min. 50 x 10 6 ops. (3 Hz) |
| Switching capacity – Minimum | 0.01 mA / 10 mV DC |
| Switching capacity – Maximum | 30 W / 62.5 VA |
| Protective circuit – AC | RC combination or VDR |
| Protective circuit – DC | Inverse diode, RC combination or VDR |
| Protective circuit – Internal | None |
| Variant | Relay / Changeover contact ; Channels are single-channel isolated. |
| Nominal voltage | 30 VDC / 115 VAC |
| Max. voltage | 125 VAC |
| Switching voltage | Max. 110 VDC / 125 VAC |
| Rated frequency | DC / 45 to 63 Hz |
| Nominal output current | 1 A at 30 VDC / 0.5 A at 115 VAC |
| Total nominal current | 4 A at 30 VDC / 2 A at 115 VAC |
| Actuator power supply | External |
| Inrush current | Max. 2 A (per channel) |
| Contact resistance | 75 mΩ at 6 VDC / 1 A |
Electrical properties
| Electrical isolation | Channel isolated from channel, bus and I/O power supply |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | - |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately. |
| Pitch | 12.5 +0.2 mm |
Accessories
Required accessories (order separately)
| X20BM15 | Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe… |
| X20BM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (15)
- 2226379 CSA Certificate of Compliance X20 X67
- 64331_A1 BV Certificate of Compliance X20
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
- RINA Type Approval Certificate - X20 / Power Panel T30
- TAA00000BJ DNV Type Approval Certificate X20
- UK Declaration PLC X20
- X20, X67 KC certificates
X20DO4529: frequently asked questions
When can X20DO4529 be shipped?
X20DO4529 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20DO4529 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20DO4529 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20DO4529, subject to availability and destination.
More B&R parts