What is the B&R X20AT4222?

4 inputs for resistance temperature measurement

For PT100 and PT1000

Configurable sensor type per channel

Direct resistance measurement

Configurable 2- or 3- wire connections per module

Configurable filter time

The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.

Specifications

Short description

I/O module4 inputs for Pt100 or Pt1000 resistance temperature measurement

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – InputsYes, using LED status indicator and software
Power consumption – Bus0.01 W
Power consumption – Internal I/O1.1 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – DNVTemperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
Certifications – CCSYes
Certifications – LRENV1
Certifications – KRYes
Certifications – ABSYes
Certifications – BVEC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck
Certifications – KCYes
B&R ID code0x1BA7
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-

Resistance measurement temperature inputs

Conversion time – 1 channel20 ms with 50 Hz filter
Conversion time – 2 - 4 channels40 ms per channel with 50 Hz filter
Sensor – Sensor typeConfigurable per channel
Sensor – Pt100-200 to 850°C
Sensor – Pt1000-200 to 850°C
Max. error at 25°C – Gain±0.037% (note: Based on the current measured resistance value.)
Max. error at 25°C – Offset±0.0015% (note: Based on the entire resistance measurement range.)
Temperature sensor resolution – Pt1001 LSB = 0.1°C
Temperature sensor resolution – Pt10001 LSB = 0.1°C
Resistance measurement resolution – G = 10.1 Ω
Resistance measurement resolution – G = 20.05 Ω
Common-mode rejection – 50 Hz>80 dB
Common-mode rejection – DC>95 dB
Standardized range of values for resistance measurement – G = 10.1 to 4500 Ω
Standardized range of values for resistance measurement – G = 20.05 to 2250 Ω
Temperature sensor normalization – Pt100-200.0 to 850.0°C
Temperature sensor normalization – Pt1000-200.0 to 850.0°C
Temperature measurement monitoring – Range undershoot0x8001
Temperature measurement monitoring – Range overshoot0x7FFF
Temperature measurement monitoring – Open circuit0x7FFF
Temperature measurement monitoring – General fault0x8000
Temperature measurement monitoring – Open inputs0x7FFF
Resistance measurement monitoring – Range overshoot0xFFFF
Resistance measurement monitoring – Open circuit0xFFFF
Resistance measurement monitoring – General fault0xFFFF
Resistance measurement monitoring – Open inputs0xFFFF
InputResistance measurement with constant current supply for 2- or 3-wire connections
Digital converter resolution16-bit
Filter timeConfigurable between 1 ms and 66.7 ms
Conversion procedureSigma-delta
Output formatINT or UINT for resistance measurement
Resistance measurement range0.1 to 4500 Ω / 0.05 to 2250 Ω
Input filterFirst-order low-pass filter / cutoff frequency 500 Hz
Sensor standardEN 60751
Common-mode range>0.7 V
Insulation voltage between channel and bus500 V eff
Linearization methodInternal
Measuring current250 µA ±1.25%
Reference4530 Ω ±0.1%
Permissible input signalShort-term max. ±30 V
Max. gain drift±0.004%/°C (note: Based on the current measured resistance value.)
Max. offset drift±0.00015%/°C (note: Based on the entire resistance measurement range.)
Nonlinearity<0.001% (note: Based on the entire resistance measurement range.)
Crosstalk between channels<-93 dB

Electrical properties

Electrical isolationChannel isolated from bus; Channel not isolated from channel

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C
Temperature – Vertical mounting orientation-25 to 50°C
Temperature – Derating-
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (15)

X20AT4222: frequently asked questions

When can X20AT4222 be shipped?

X20AT4222 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20AT4222 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20AT4222 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20AT4222, subject to availability and destination.

More B&R parts

B&R X20AP3171 – I/O module, 3-phase power and energy metering module for…
B&R
X20AP3171

I/O module, 3-phase power and energy metering module for…

B&R X20AT2222 – I/O module, 2 inputs for Pt100 or Pt1000 resistance…
B&R
X20AT2222

I/O module, 2 inputs for Pt100 or Pt1000 resistance…

B&R X20AT2311 – I/O module, 2 inputs for PT100 resistance temperature…
B&R
X20AT2311

I/O module, 2 inputs for PT100 resistance temperature…

B&R X20AT2402 – I/O module, 2 inputs for thermocouples
B&R
X20AT2402

I/O module, 2 inputs for thermocouples

B&R X20AT4232 – I/O module, 4 inputs for NTC (10 kΩ) resistance temperature…
B&R
X20AT4232

I/O module, 4 inputs for NTC (10 kΩ) resistance temperature…

B&R X20AT6402 – I/O module, 6 inputs for thermocouples
B&R
X20AT6402

I/O module, 6 inputs for thermocouples

B&R X20ATA312 – I/O module, 2 inputs for Pt100 resistance temperature…
B&R
X20ATA312

I/O module, 2 inputs for Pt100 resistance temperature…

B&R X20ATA492 – I/O module, 2 inputs for thermocouples
B&R
X20ATA492

I/O module, 2 inputs for thermocouples

B&R X20AT4222€137.80
Buy Now