B&R 8BVE0500HC00.000-1

For distributing the DC bus power supply and 24 VDC…

MPN
8BVE0500HC00.000-1
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare B&R parts? We buy surplus →

What is the B&R 8BVE0500HC00.000-1?

For distributing the DC bus power supply and 24 VDC auxiliary supply to multiple mounting plates

For setting up decentralized units in the ACOPOSmulti drive system

Output for overload protection

ACOPOSmulti expansion module 40 A, AS, cold plate or pass-through mounting

Specifications

General information

Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)Not applicable
Certifications – ULcULus E225616; Power conversion equipment
Certifications – KCYes
Cooling and mounting typeCold plate or pass-through mounting

DC bus connection

Voltage – Nominal750 VDC
Continuous power depending on fuse – 10 A6 kW (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level.)
Continuous power depending on fuse – 20 A12 kW (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level.)
Continuous power depending on fuse – 50 A30 kW (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level.)
Continuous current depending on fuse – 10 A8 A eff (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.)
Continuous current depending on fuse – 20 A16 A eff (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.)
Continuous current depending on fuse – 50 A40 A eff (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.)
Reduction of continuous power depending on installation elevation – Starting at 500 m above sea level10% per 1000 m
Peak current depending on fuse – 10 A20 A
Peak current depending on fuse – 20 A40 A
Peak current depending on fuse – 50 A100 A
Reduction of continuous power at ambient temperatures starting at 40°C1.25% per °Kelvin (note: Continuous power valid at a DC bus voltage of 750 VDC.)
Reduction of continuous power depending on cooling methodNo reduction
Power dissipation with continuous power200 W (note: Continuous power valid at a DC bus voltage of 750 VDC including power dissipation of the damping resistors.)
VariantACOPOSmulti backplane

24 VDC power supply

Continuous power depending on fuse – 12 A240 W (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level)
Continuous power depending on fuse – 20 A400 W (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level)
Continuous power depending on fuse – 30 A600 W (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level)
Input voltage25 VDC ±1.6%
Max. power consumption5 W
Reduction of continuous power at ambient temperatures starting at 40°C1.25% per °Kelvin
VariantACOPOSmulti backplane

DC bus cable outlet

Fuse protection – Type2x melting fuse ø 14 x 51 mm
Fuse protection – Tripping characteristicUltra fast-acting
Fuse protection – Rated current10 / 20 / 25 / 50 A (note: For a 10 A rated current, type 5011806.10 fuses from Siba (www.sibafuses.com) must be used. For a 20 A rated current, type 5011806.20 fuses from Siba (www.sibafuses.com) must be used. For a 50 A rated current, type 5020106.50 fuses from Siba (www.sibafuses.com) must be used.)
Protective measures – 10 ANo (overload indicated via LED, dry alarm contacts present)
Protective measures – 20 ANo (overload indicated via LED, dry alarm contacts present)
Protective measures – 50 ANo (overload indicated via LED, dry alarm contacts present)
Protective measures – Short-circuit and ground fault protectionYes
Variant – DC+, DC-, PEConnector
Variant – Shield connectionYes
Terminal connection cross section – With wire end sleeve0.5 to 16 mm²
Terminal connection cross section – UL/C-UL-US20 to 6 AWG
Terminal connection cross section – CSA20 to 6 AWG
Quantity2
Max. line length between two expansion modules5 m
Terminal cable cross section dimension of shield connection12 to 22 mm

24 VDC auxiliary supply cable outlet

Output voltage – DC bus voltage (U DC ): 260 to 315 VDC25 VDC * (DC bus voltage / 315)
Output voltage – DC bus voltage (U DC ): 315 to 800 VDC24 VDC ±6%
Fuse protection – TypeMelting fuse ø 10 x 38 mm (note: For example, a fuse of type KLKD0xx from Littelfuse (www.littelfuse.com) can be used (xx is the rated current for the fuse; only fuses up to a rated current of 30 A are permitted to be used).)
Fuse protection – Tripping characteristicFast-acting
Fuse protection – Rated current12 / 30 A
Protective measures – Overload protectionYes
Protective measures – Short-circuit proofYes
Variant – 24 VDC, COMConnector
Variant – Shield connectionNo
Terminal connection cross section – With wire end sleeve0.25 to 6 mm²
Terminal connection cross section – UL/C-UL-US22 to 10 AWG
Terminal connection cross section – CSA22 to 10 AWG
Quantity2
Max. line length between two expansion modules5 m

Alarm contacts

Type – Alarm contact 1Normally closed contact
Type – Alarm contact 2Normally open contact
Electrical isolation – Alarm contact - ACOPOSmulti moduleYes
Electrical isolation – Alarm contact - Alarm contactYes
Protection – Overload-proofNo
Protection – Short-circuit proofNo
Quantity2
Nominal voltage30 VDC
Maximum current1 A
Switching delay3 ms
Max. number of switching cycles100,000

Operating conditions

Permissible mounting orientations – Hanging verticallyYes
Permissible mounting orientations – Horizontal, face upYes
Permissible mounting orientations – Standing horizontallyNo
Installation elevation above sea level – Nominal0 to 500 m
Installation elevation above sea level – Maximum4000 m (note: Continuous operation at an installation elevation of 500 m to 4,000 m above sea level is possible taking the specified reduction of continuous current into account. Requirements that go beyond this must be arranged with B&R.)
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Nominal5 to 40°C
Temperature – Maximum55°C
Temperature – Storage-25 to 55°C
Temperature – Transport-25 to 70°C
Relative humidity – Operation5 to 85%
Relative humidity – Storage5 to 95%
Relative humidity – TransportMax. 95% at 40°C

Mechanical properties

Dimensions – Cold plate212 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
Dimensions – Pass-through mounting209 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
Dimensions – Width53 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
Dimensions – Height317 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.)
WeightApprox. 2.6 kg
Module width1

Accessories

Required accessories (order separately)

8BXS005.0000-00Fuse sets — ACOPOSmulti fuse set: 2x fuse 14 x 51 mm, 25 A, high-speed
8BXS004.0000-00Fuse sets — ACOPOSmulti fuse set: 1x fuse 10 x 38 mm, 12 A, fast-acting
8BXS003.0000-00Fuse sets — ACOPOSmulti fuse set: 1x fuse 10 x 38 mm, 30 A, fast-acting
8BXS002.0000-00Fuse sets — ACOPOSmulti fuse set: 2x fuse 14 x 51 mm, 10 A, high-speed
8BXS001.0000-00Fuse sets — ACOPOSmulti fuse set: 2x fuse 14 x 51 mm, 20 A, high-speed
8BXS000.0000-00Fuse sets — ACOPOSmulti fuse set: 2x fuse 14 x 51 mm, 50 A, high-speed
8BZVE050000.000-1ATerminal block sets — Screw clamp terminal block set for ACOPOSmulti 8BVE0500Hx00.000-1 modules: 2x 8TB3102.201C-11, 2x 8TB4103.203C-10, 1x 8TB2104.2010-00
Optional accessories (20)
8CCH0010.11120-18BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H…
8CCH0009.11120-18BVE / 8CVI connection cables — UL/CSA listed; Cables for connecting 8BVE ACOPOSmulti expansion modules and ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system…
8CCH0007.11120-18BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H…
8CCH0005.11120-18BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H…
8CCH0002.11120-18BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H…
8BCA01X5.1513A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BCA01X5.1312A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BCA01X5.1111A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BCA0005.1513A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BCA0005.1312A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BCA0005.1111A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BCA0003.1513A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BCA0003.1312A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BCA0003.1111A-0Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ…
8BXF001.0000-00Fan modules — ACOPOSmulti fan module, replacement fan for ACOPOSmulti modules (8BxP/8B0C/8BVI/8BVE/8B0K)
8SCS009.0000-00Shield component sets — ACOPOSmulti shield component set: 1x ACOPOSmulti holding plate SK8-14, 1x shield connection clamp SK14
8SCS000.0000-00Shield component sets — ACOPOSmulti shield component set: 1x shield plate 1x type 0, 1x hose clamp, B 9 mm, D 12-22 mm
8TB4103.203C-10Terminal blocks — 3-pin screw clamp terminal block, 1-row, pitch: 10.16 mm, label 3: +DC -DC PE, coding C: 010
8TB3102.201C-11Terminal blocks — 2-pin screw clamp terminal block, 1-row, pitch: 7.62 mm, label 1: Numbered consecutively, coding C: 10
8TB2104.2010-00Terminal blocks — 4-pin screw clamp terminal block, 1-row, pitch: 5.08 mm, label 1: Numbered consecutively

8BVE0500HC00.000-1: frequently asked questions

When can 8BVE0500HC00.000-1 be shipped?

8BVE0500HC00.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8BVE0500HC00.000-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8BVE0500HC00.000-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8BVE0500HC00.000-1, subject to availability and destination.

More B&R parts

B&R 8BVE0500HW00.000-1 – For distributing the DC bus power supply and 24 VDC…
B&R
8BVE0500HW00.000-1

For distributing the DC bus power supply and 24 VDC…

B&R 8BVF0440H000.001-2 – ACOPOSmulti line filter, 45 A, 480 V, increased peak current carrying capacity
B&R
8BVF0440H000.001-2

ACOPOSmulti line filter, 45 A, 480 V, increased peak current carrying capacity

B&R 8BVE0500HC00.000-1Price and lead time confirmed within 1 business day
Request a Quote