B&R 8BVE0500HC00.000-1
For distributing the DC bus power supply and 24 VDC…
- MPN
- 8BVE0500HC00.000-1
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the B&R 8BVE0500HC00.000-1?
For distributing the DC bus power supply and 24 VDC auxiliary supply to multiple mounting plates
For setting up decentralized units in the ACOPOSmulti drive system
Output for overload protection
ACOPOSmulti expansion module 40 A, AS, cold plate or pass-through mounting
Specifications
General information
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | Not applicable |
| Certifications – UL | cULus E225616; Power conversion equipment |
| Certifications – KC | Yes |
| Cooling and mounting type | Cold plate or pass-through mounting |
DC bus connection
| Voltage – Nominal | 750 VDC |
| Continuous power depending on fuse – 10 A | 6 kW (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level.) |
| Continuous power depending on fuse – 20 A | 12 kW (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level.) |
| Continuous power depending on fuse – 50 A | 30 kW (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level.) |
| Continuous current depending on fuse – 10 A | 8 A eff (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.) |
| Continuous current depending on fuse – 20 A | 16 A eff (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.) |
| Continuous current depending on fuse – 50 A | 40 A eff (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.) |
| Reduction of continuous power depending on installation elevation – Starting at 500 m above sea level | 10% per 1000 m |
| Peak current depending on fuse – 10 A | 20 A |
| Peak current depending on fuse – 20 A | 40 A |
| Peak current depending on fuse – 50 A | 100 A |
| Reduction of continuous power at ambient temperatures starting at 40°C | 1.25% per °Kelvin (note: Continuous power valid at a DC bus voltage of 750 VDC.) |
| Reduction of continuous power depending on cooling method | No reduction |
| Power dissipation with continuous power | 200 W (note: Continuous power valid at a DC bus voltage of 750 VDC including power dissipation of the damping resistors.) |
| Variant | ACOPOSmulti backplane |
24 VDC power supply
| Continuous power depending on fuse – 12 A | 240 W (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level) |
| Continuous power depending on fuse – 20 A | 400 W (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level) |
| Continuous power depending on fuse – 30 A | 600 W (note: Valid under the following conditions: 40°C ambient temperature, installation elevation <500 m above sea level) |
| Input voltage | 25 VDC ±1.6% |
| Max. power consumption | 5 W |
| Reduction of continuous power at ambient temperatures starting at 40°C | 1.25% per °Kelvin |
| Variant | ACOPOSmulti backplane |
DC bus cable outlet
| Fuse protection – Type | 2x melting fuse ø 14 x 51 mm |
| Fuse protection – Tripping characteristic | Ultra fast-acting |
| Fuse protection – Rated current | 10 / 20 / 25 / 50 A (note: For a 10 A rated current, type 5011806.10 fuses from Siba (www.sibafuses.com) must be used. For a 20 A rated current, type 5011806.20 fuses from Siba (www.sibafuses.com) must be used. For a 50 A rated current, type 5020106.50 fuses from Siba (www.sibafuses.com) must be used.) |
| Protective measures – 10 A | No (overload indicated via LED, dry alarm contacts present) |
| Protective measures – 20 A | No (overload indicated via LED, dry alarm contacts present) |
| Protective measures – 50 A | No (overload indicated via LED, dry alarm contacts present) |
| Protective measures – Short-circuit and ground fault protection | Yes |
| Variant – DC+, DC-, PE | Connector |
| Variant – Shield connection | Yes |
| Terminal connection cross section – With wire end sleeve | 0.5 to 16 mm² |
| Terminal connection cross section – UL/C-UL-US | 20 to 6 AWG |
| Terminal connection cross section – CSA | 20 to 6 AWG |
| Quantity | 2 |
| Max. line length between two expansion modules | 5 m |
| Terminal cable cross section dimension of shield connection | 12 to 22 mm |
24 VDC auxiliary supply cable outlet
| Output voltage – DC bus voltage (U DC ): 260 to 315 VDC | 25 VDC * (DC bus voltage / 315) |
| Output voltage – DC bus voltage (U DC ): 315 to 800 VDC | 24 VDC ±6% |
| Fuse protection – Type | Melting fuse ø 10 x 38 mm (note: For example, a fuse of type KLKD0xx from Littelfuse (www.littelfuse.com) can be used (xx is the rated current for the fuse; only fuses up to a rated current of 30 A are permitted to be used).) |
| Fuse protection – Tripping characteristic | Fast-acting |
| Fuse protection – Rated current | 12 / 30 A |
| Protective measures – Overload protection | Yes |
| Protective measures – Short-circuit proof | Yes |
| Variant – 24 VDC, COM | Connector |
| Variant – Shield connection | No |
| Terminal connection cross section – With wire end sleeve | 0.25 to 6 mm² |
| Terminal connection cross section – UL/C-UL-US | 22 to 10 AWG |
| Terminal connection cross section – CSA | 22 to 10 AWG |
| Quantity | 2 |
| Max. line length between two expansion modules | 5 m |
Alarm contacts
| Type – Alarm contact 1 | Normally closed contact |
| Type – Alarm contact 2 | Normally open contact |
| Electrical isolation – Alarm contact - ACOPOSmulti module | Yes |
| Electrical isolation – Alarm contact - Alarm contact | Yes |
| Protection – Overload-proof | No |
| Protection – Short-circuit proof | No |
| Quantity | 2 |
| Nominal voltage | 30 VDC |
| Maximum current | 1 A |
| Switching delay | 3 ms |
| Max. number of switching cycles | 100,000 |
Operating conditions
| Permissible mounting orientations – Hanging vertically | Yes |
| Permissible mounting orientations – Horizontal, face up | Yes |
| Permissible mounting orientations – Standing horizontally | No |
| Installation elevation above sea level – Nominal | 0 to 500 m |
| Installation elevation above sea level – Maximum | 4000 m (note: Continuous operation at an installation elevation of 500 m to 4,000 m above sea level is possible taking the specified reduction of continuous current into account. Requirements that go beyond this must be arranged with B&R.) |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Nominal | 5 to 40°C |
| Temperature – Maximum | 55°C |
| Temperature – Storage | -25 to 55°C |
| Temperature – Transport | -25 to 70°C |
| Relative humidity – Operation | 5 to 85% |
| Relative humidity – Storage | 5 to 95% |
| Relative humidity – Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions – Cold plate | 212 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.) |
| Dimensions – Pass-through mounting | 209 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.) |
| Dimensions – Width | 53 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.) |
| Dimensions – Height | 317 mm (note: These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation.) |
| Weight | Approx. 2.6 kg |
| Module width | 1 |
No matching specifications
Accessories
Required accessories (order separately)
| 8BXS005.0000-00 | Fuse sets — ACOPOSmulti fuse set: 2x fuse 14 x 51 mm, 25 A, high-speed |
| 8BXS004.0000-00 | Fuse sets — ACOPOSmulti fuse set: 1x fuse 10 x 38 mm, 12 A, fast-acting |
| 8BXS003.0000-00 | Fuse sets — ACOPOSmulti fuse set: 1x fuse 10 x 38 mm, 30 A, fast-acting |
| 8BXS002.0000-00 | Fuse sets — ACOPOSmulti fuse set: 2x fuse 14 x 51 mm, 10 A, high-speed |
| 8BXS001.0000-00 | Fuse sets — ACOPOSmulti fuse set: 2x fuse 14 x 51 mm, 20 A, high-speed |
| 8BXS000.0000-00 | Fuse sets — ACOPOSmulti fuse set: 2x fuse 14 x 51 mm, 50 A, high-speed |
| 8BZVE050000.000-1A | Terminal block sets — Screw clamp terminal block set for ACOPOSmulti 8BVE0500Hx00.000-1 modules: 2x 8TB3102.201C-11, 2x 8TB4103.203C-10, 1x 8TB2104.2010-00 |
Optional accessories (20)
| 8CCH0010.11120-1 | 8BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H… |
| 8CCH0009.11120-1 | 8BVE / 8CVI connection cables — UL/CSA listed; Cables for connecting 8BVE ACOPOSmulti expansion modules and ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system… |
| 8CCH0007.11120-1 | 8BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H… |
| 8CCH0005.11120-1 | 8BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H… |
| 8CCH0002.11120-1 | 8BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H… |
| 8BCA01X5.1513A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BCA01X5.1312A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BCA01X5.1111A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BCA0005.1513A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BCA0005.1312A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BCA0005.1111A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BCA0003.1513A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BCA0003.1312A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BCA0003.1111A-0 | Expansion cables — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for DC connection between ACOPOSmulti expansion modules 8BVE; Integ… |
| 8BXF001.0000-00 | Fan modules — ACOPOSmulti fan module, replacement fan for ACOPOSmulti modules (8BxP/8B0C/8BVI/8BVE/8B0K) |
| 8SCS009.0000-00 | Shield component sets — ACOPOSmulti shield component set: 1x ACOPOSmulti holding plate SK8-14, 1x shield connection clamp SK14 |
| 8SCS000.0000-00 | Shield component sets — ACOPOSmulti shield component set: 1x shield plate 1x type 0, 1x hose clamp, B 9 mm, D 12-22 mm |
| 8TB4103.203C-10 | Terminal blocks — 3-pin screw clamp terminal block, 1-row, pitch: 10.16 mm, label 3: +DC -DC PE, coding C: 010 |
| 8TB3102.201C-11 | Terminal blocks — 2-pin screw clamp terminal block, 1-row, pitch: 7.62 mm, label 1: Numbered consecutively, coding C: 10 |
| 8TB2104.2010-00 | Terminal blocks — 4-pin screw clamp terminal block, 1-row, pitch: 5.08 mm, label 1: Numbered consecutively |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
8BVE0500HC00.000-1: frequently asked questions
When can 8BVE0500HC00.000-1 be shipped?
8BVE0500HC00.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8BVE0500HC00.000-1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8BVE0500HC00.000-1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8BVE0500HC00.000-1, subject to availability and destination.