SIRIUS 3RV2 motor starter protectors Parts

Showing 193–216 of 445 parts
Siemens 3RV2021-1EA10 – Circuit breaker size S0 for motor protection
Siemens
3RV2021-1EA10

Circuit breaker size S0 for motor protection

Siemens 3RV2021-1DA25 – Circuit breaker size S0 for motor protection
Siemens
3RV2021-1DA25

Circuit breaker size S0 for motor protection

Siemens 3RV2021-1CA25 – Circuit breaker size S0 for motor protection
Siemens
3RV2021-1CA25

Circuit breaker size S0 for motor protection

Siemens 3RV2021-1CA20-0BA0 – Special type Circuit breaker size S0 for motor protection
Siemens
3RV2021-1CA20-0BA0

Special type Circuit breaker size S0 for motor protection

Siemens 3RV2011-1CA10-0BA0 – Special type Circuit breaker size S00 for motor protection
Siemens
3RV2011-1CA10-0BA0

Special type Circuit breaker size S00 for motor protection

Siemens 3RV2011-1CA10 – Circuit breaker size S00 for motor protection
Siemens
3RV2011-1CA10

Circuit breaker size S00 for motor protection

Siemens 3RV2032-4UA15 – Circuit breaker size S2 for motor protection
Siemens
3RV2032-4UA15

Circuit breaker size S2 for motor protection

Siemens 3RV2411-1JA20-0DA0 – Circuit breaker size S00 for transformer protection without phase failure protection A-release 7...10 A…
Siemens
3RV2411-1JA20-0DA0

Circuit breaker size S00 for transformer protection without…

Siemens 3RV2411-1JA20 – Circuit breaker size S00 for transformer protection A-release 7...10 A N-release 208 A Spring-type terminal…
Siemens
3RV2411-1JA20

Circuit breaker size S00 for transformer protection…

Siemens 3RV2411-1JA15 – Circuit breaker size S00 for transformer protection A-release 7...10 A N-release 208 A screw terminal…
Siemens
3RV2411-1JA15

Circuit breaker size S00 for transformer protection…

Siemens 3RV2411-1JA10-0BA0 – Special type Circuit breaker size S00 for transformer protection A-release 7...10 A N-release 208 A screw…
Siemens
3RV2411-1JA10-0BA0

Special type Circuit breaker size S00 for transformer…

Siemens 3RV2411-1JA10 – Circuit breaker size S00 for transformer protection A-release 7...10 A N-release 208 A screw terminal…
Siemens
3RV2411-1JA10

Circuit breaker size S00 for transformer protection…

Siemens 3RV2411-1HA20-0DA0 – Circuit breaker size S00 for transformer protection without phase failure protection A-release 5.5...8 A…
Siemens
3RV2411-1HA20-0DA0

Circuit breaker size S00 for transformer protection without…

Siemens 3RV2411-1HA20 – Circuit breaker size S00 for transformer protection A-release 5.5...8 A N-release 163 A Spring-type terminal…
Siemens
3RV2411-1HA20

Circuit breaker size S00 for transformer protection…

Siemens 3RV2321-4AC20 – Circuit breaker size S0 for starter combination rated current 16 A N-release 208 A Spring-type terminal…
Siemens
3RV2321-4AC20

Circuit breaker size S0 for starter combination rated…

Siemens 3RV2321-1AC10 – Circuit breaker size S0 for starter combination Rated current 1.6 A N-release 21 A screw terminal Standard…
Siemens
3RV2321-1AC10

Circuit breaker size S0 for starter combination Rated…

Siemens 3RV2311-4AC20-0BA0 – Special type Circuit breaker size S00 for starter combination rated current 16 A N-release 208 A Spring-type…
Siemens
3RV2311-4AC20-0BA0

Special type Circuit breaker size S00 for starter…

Siemens 3RV2311-4AC20 – Circuit breaker size S00 for starter combination rated current 16 A N-release 208 A Spring-type terminal…
Siemens
3RV2311-4AC20

Circuit breaker size S00 for starter combination rated…

Compare SIRIUS 3RV2 motor starter protectors

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNcontinuous current rated valueNet Weightadjustable current response value current of the current-dependent overload releaseoperational current rated valueresponse value current of instantaneous short-circuit trip unit
3RV2021-1EA104 A328.6 g2.8 ... 4 A4 A52 A
3RV2021-1DA253.2 A391.6 g2.2 ... 3.2 A3.2 A42 A
3RV2021-1DA20-Z X953.2 A380.6 g2.2 ... 3.2 A3.2 A42 A
3RV2021-1CA252.5 A392.6 g1.8 ... 2.5 A2.5 A33 A
3RV2021-1CA20-0BA02.5 A0.377 kg1.8 ... 2.5 A2.5 A33 A
3RV2021-1CA20-Z X952.5 A372.6 g1.8 ... 2.5 A2.5 A33 A
3RV2011-1CA10-0BA02.5 A321.6 g1.8 ... 2.5 A2.5 A33 A
3RV2011-1CA10-Z X952.5 A323.6 g1.8 ... 2.5 A2.5 A33 A
3RV2011-1CA10-Z W972.5 A323.6 g1.8 ... 2.5 A2.5 A33 A
3RV2011-1CA10-Z W962.5 A323.6 g1.8 ... 2.5 A2.5 A33 A
3RV2011-1CA102.5 A323.6 g1.8 ... 2.5 A2.5 A33 A
3RV2011-1BA25-Z X952 A356.6 g1.4 ... 2 A2 A26 A
3RV2032-4UA1540 A1.153 kg32 ... 40 A40 A585 A
3RV2411-1JA20-0DA010 A353.6 g7 ... 10 A10 A208 A
3RV2411-1JA2010 A351.6 g7 ... 10 A10 A208 A
3RV2411-1JA1510 A347.18 g7 ... 10 A10 A208 A
3RV2411-1JA10-0BA010 A0.336 kg7 ... 10 A10 A208 A
3RV2411-1JA1010 A330.6 g7 ... 10 A10 A208 A
3RV2411-1HA20-0DA08 A344.6 g5.5 ... 8 A8 A163 A
3RV2411-1HA208 A345.6 g5.5 ... 8 A8 A163 A
3RV2321-4AC2016 A386.6 g—16 A208 A
3RV2321-1AC101.6 A0.325 kg—1.6 A21 A
3RV2311-4AC20-0BA016 A0.347 kg—16 A208 A
3RV2311-4AC2016 A348.6 g—16 A208 A

Common to all listed parts

Product equipment of circuit breaker for motor protection complete unit with protection deviceYes
product function disconnector functionalityYes
product extension auxiliary switchYes
type of calculation of power loss current-dependentquadratic
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value6 kV
reference code according to IEC 81346-2Q
installation altitude at height above sea level maximum2 000 m