Wago 857-550

Current signal conditioner; Current input signal; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

MPN
857-550
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Wago parts? We buy surplus →

What is the Wago 857-550?

Short description:

This current signal conditioner measures both 0–1 A and 0–5 A AC/DC currents, converting the input signal to an standard analog signal at the output.

Digital switching output (DO):

The digital switching output (DO) allows signaling of a message. Two switching behaviors can be selected for the edge:

GND switching: For all values below the lower threshold or above the upper threshold, the digital output switches to “GND.”

U s switching: For all values below the lower threshold or above the upper threshold, the digital output (DO) matches the supply voltage level.

The preset switching thresholds are 0% and 100% of the input measurement range. These thresholds can be adjusted via the PC configuration interface. The switching threshold hysteresis is 5 mA.

Features:

PC configuration interface

True RMS measurement or arithmetic mean value

Digital switching output (configurable switching thresholds)

Switchable filter function

Calibrated measurement range switching

3-way electrical isolation with 2.5 kV test voltage

Extremely fast response times

Measurement range overflow indication

Specifications

Notes

Safety InformationInput and output must be safely isolated from any hazardous live parts!
NoteAdditional setting options via the WAGO Interface Configuration Software, Use shielded signal cables!Only use shielded signal cables for analog output signals.This ensures the device maintains its specified accuracy and immunity to interference, even when external disturbances affect the signal cable.

Technical data - Configuration

Configuration optionsDIP switch, WAGO Interface Configuration Software

Technical data - Input

Input signal typeCurrent
Input signal (current)0 … 1 A AC/DC (IN 1), 0 … 5 A AC/DC (IN 2)
Frequency range16 … 400 Hz
Input resistance (current input)47 mΩ (IN 1), 10 mΩ (IN 2)
Input current (max.)10 A (IN 1; 5 s); 15 A (IN 2; 5 s)
Response threshold2 mA (IN 1); 4 mA (IN 2)

Technical data - Output (analog)

Output signal typeCurrent, Voltage
Output signal (voltage)0 … 5 V, 1 … 5 V, 0 … 10 V, 2 … 10 V
Output signal (current)0 … 10 mA, 2 … 10 mA, 0 … 20 mA, 4 … 20 mA
Load impedance (voltage output)≥ 2 kΩ (Temperature range restrictions may occur.)
Load impedance (current output)≤ 600 Ω Temperature range restrictions may occur.

Technical data - Output (digital)

Switching voltage (DO) max.Supply voltage applied
Continuous current (DO) max.100 mA (no internal restriction)
Number of switching thresholds (DO)1 (adjustable)

Technical data - Signal processing

Measurement methodTrue RMS measurement; Arithmetic mean value
Software filter (adjustable)Moving average value (filter level: 30)
Step response (typ.)60 ms

Technical data - Measurement error

Transmission error (typ.)≤ 0.1 % of upper-range value
Transmission error (max.)≤ 0.4 % of upper-range value
Temperature coefficient≤ 0.01 %/K

Technical data - Power supply

Power supply type24 VDC (SELV)
Nominal supply voltage U<sub>S</sub>24 VDC
Supply voltage range±30 %
Current consumption at nominal supply voltage≤ 40 mA (+ IDO)

Safety and protection

Rated voltage300 V
Protection typeIP20

Safety and protection - Test voltage

Test voltage (input/output/supply)2.5 kVAC; 50 Hz; 1 min

Safety and protection - Insulation coordination

Overvoltage categoryII
Pollution degree2
Insulation type (input/analog output/supply)Functional insulation
Insulation type (adjacent devices)Reinforced insulation (safe isolation)

Connection data

Connection technologyPush-in CAGE CLAMP®
Solid conductor0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor0.34 … 2.5 mm² / 22 … 14 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width6 mm / 0.236 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail97.8 mm / 3.85 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.418 MJ
Weight64 g

Environmental requirements

Ambient temperature (operation)-25 … +70 °C (At nominal current, in individual arrangement; -25 … +60 °C (block arrangement))
Ambient temperature (storage)-40 … +85 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≥ (Tambient + 25 K)
Relative humidity5 … 95 % (no condensation permissible)
Operating altitude (max.)2000 m

Standards and specifications

Conformity markingCE
EMC immunity to interferenceEN 61000-6-2
EMC emission of interferenceEN 61000-6-3; EN 61000-6-4
Standards/specificationsEN 50121-3-2, DNV, EN 61010-2-201

Commercial data

Product Group6 (INTERFACE ELECTRONIC)
PU (SPU)1 pcs
Packaging typebag
Country of originDE
GTIN4050821226734
Customs tariff number85437090300

Product Classification

UNSPSC41113630
eCl@ss 10.027-21-01-23
eCl@ss 9.027-21-01-23
ETIM 9.0EC002475
ETIM 10.0EC002475
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1, 75980-60-8, 79-94-7, 80-05-7
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, 4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide, Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)50f64a02-d6d3-4adb-a7b9-f815da2344ad
SCIP notification number (Belgium)0e04df68-4c33-4c78-ade6-82bf60716e8f
SCIP notification number (Bulgaria)d1dc9f2a-4544-48c8-8c42-717ec18dc517
SCIP notification number (Czech Republic)1a2ce406-9928-4d64-aeb5-27a0e58a61ff
SCIP notification number (Denmark)4e1a4190-497b-4457-98c6-445a2a2407aa
SCIP notification number (Finland)10e56fdb-95fd-4317-8b19-0eec048887fc
SCIP notification number (France)0152e5b3-4bb3-407b-962c-95da92c8f591
SCIP notification number (Germany)7d05eaec-2f49-4372-825c-639900cb0cfa
SCIP notification number (Hungary)8a6d556b-a2a5-47d7-be2c-0f7f08b455aa
SCIP notification number (Italy)80363ecc-0750-47b3-8adc-6d8d376cb109
SCIP notification number (Netherlands)4c0930d7-0757-44b2-a2ac-a852f21c8101
SCIP notification number (Poland)e163f598-e916-448a-8e77-616fb920165c
SCIP notification number (Romania)c1c27efe-e372-4fb2-b5a4-5eac757ec01f
SCIP notification number (Sweden)6a471be4-9d63-4d9d-9da5-8ddf090e997c

857-550: frequently asked questions

When can 857-550 be shipped?

857-550 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 857-550 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 857-550 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 857-550, subject to availability and destination.

More Wago parts

Wago 857-451 – Passive isolator, 1-channel; Current input signal; Current output signal; Power via input; 6 mm module width; 2,50 mm²
Wago
857-451

Passive isolator, 1-channel; Current input signal; Current output signal; Power via input; 6 mm module width; 2,50 mm²

Wago 857-452 – Passive isolator, 2-channel; 2 x current input signal; 2 x current output signal; Power via input; 6 mm module width; 2,50 mm²
Wago
857-452

Passive isolator, 2-channel; 2 x current input signal; 2 x current output signal; Power via input; 6 mm module width; 2,50 mm²

Wago 857-500 – Frequency signal conditioner; Current and voltage output signal; Configuration via software; Supply voltage: 24 VDC; 6 mm module width
Wago
857-500

Frequency signal conditioner; Current and voltage output signal; Configuration via software; Supply voltage: 24 VDC; 6 mm module width

Wago 857-531 – Threshold value switches; Analog values; 1 changeover contact; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²
Wago
857-531

Threshold value switches; Analog values; 1 changeover contact; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Wago 857-551 – Current signal conditioner; Current input signal; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width
Wago
857-551

Current signal conditioner; Current input signal; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width

Wago 857-552 – Current signal conditioner; Input for Rogowski coils; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²
Wago
857-552

Current signal conditioner; Input for Rogowski coils; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Wago 857-560 – Voltage signal conditioner; Voltage input signal; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width
Wago
857-560

Voltage signal conditioner; Voltage input signal; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width

Wago 857-569 – Power signal conditioner; Current and voltage input signal; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width
Wago
857-569

Power signal conditioner; Current and voltage input signal; Current and voltage output signal; Digital output; Configuration via software; Supply voltage: 24 VDC; 6 mm module width

Wago 857-550Price and lead time confirmed within 1 business day
Request a Quote