Wago 857-411

Isolation amplifier; Current input signal; Current output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

MPN
857-411
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Wago parts? We buy surplus →

What is the Wago 857-411?

Short description:

This pre-configured signal conditioner converts, amplifies, filters and electrically isolates analog standard signals.

Features:

Input/output: current or voltage signal

3-way electrical isolation with 3 kV test voltage

Specifications

Notes

Safety InformationInput and output must be safely isolated from any hazardous live parts!
NoteThe 3 (Us+), 7 (Us+), 4 (GND 3) and 8 (GND 3) connections are internally commoned.Current carrying capacity between 3/4 and 7/8 connections: 1 A (max.), Use shielded signal cables!Only use shielded signal cables for analog input and output signals.This ensures the device maintains its specified accuracy and immunity to interference, even when external disturbances affect the signal cable.

Technical data - Configuration

Configuration optionsPre-configured

Technical data - Input

Input signal typeCurrent
Input signal (current)0 … 20 mA, 4 … 20 mA
Input resistance (current input)≤ 50 Ω
Input current (max.)50 mA
Input voltage (max.)30 V

Technical data - Output (analog)

Output signal typeCurrent
Output signal (current)0 … 20 mA, 4 … 20 mA
Load impedance (current output)≤ 600 Ω

Technical data - Signal processing

Limit frequency100 Hz
Step response (typ.)3.5 ms

Technical data - Measurement error

Transmission error (typ.)≤ 0.1 % of upper-range value
Temperature coefficient≤ 0.01 %/K

Technical data - Power supply

Power supply type24 VDC (SELV)
Nominal supply voltage U<sub>S</sub>24 VDC
Supply voltage range±30 %
Current consumption at nominal supply voltage≤ 30 mA

Technical data - Operating data

Current consumption≤ 40 mA

Safety and protection

Rated voltage300 V
Protection typeIP20

Safety and protection - Test voltage

Test voltage (input/output/supply)3 kVAC; 50 Hz; 1 min

Safety and protection - Insulation coordination

Overvoltage categoryII
Pollution degree2
Insulation type (input IN 2.1/relay output)Functional insulation
Insulation type (adjacent devices)Reinforced insulation (safe isolation)

Connection data

Connection technologyPush-in CAGE CLAMP®
Solid conductor0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor0.34 … 2.5 mm² / 22 … 14 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width6 mm / 0.236 inches
Height94 mm / 3.701 inches
Depth from upper-edge of DIN-rail97.8 mm / 3.85 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.543 MJ
Weight36.1 g

Environmental requirements

Ambient temperature (operation)-25 … +70 °C
Ambient temperature (storage)-40 … +85 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≥ (Tambient + 25 K)
Relative humidity5 … 95 % (no condensation permissible)
Operating altitude (max.)2000 m

Standards and specifications

Conformity markingCE
EMC immunity to interferenceEN 61000-6-2
EMC emission of interferenceEN 61000-6-4
Standards/specificationsEN 61010-1, UL 508

Commercial data

Product Group6 (INTERFACE ELECTRONIC)
PU (SPU)1 pcs
Packaging typebag
Country of originDE
GTIN4045454471224
Customs tariff number85437090300

Product Classification

UNSPSC39121008
eCl@ss 10.027-21-01-20
eCl@ss 9.027-21-01-20
ETIM 9.0EC002653
ETIM 10.0EC002653
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1, 75980-60-8
REACH Candidate List SubstanceDiboron trioxide, Lead, Lead monoxide, Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)e1a379a9-9a12-43c5-ba97-78cd431a5012
SCIP notification number (Belgium)a3504f54-5762-4675-86e4-06b3a5cee394
SCIP notification number (Bulgaria)329d10ce-3573-4f6f-967f-f227f641d686
SCIP notification number (Czech Republic)ccbda9d3-1048-44d4-b2ae-66419bd577c0
SCIP notification number (Denmark)2e5f76a3-2103-4880-b174-4de45b1ae8e4
SCIP notification number (Finland)32b6734a-1a59-449b-93fd-5bd651f6e1b1
SCIP notification number (France)162cb9fc-1c93-4dec-8237-9d60232fce19
SCIP notification number (Germany)d027a0a8-794c-4140-8453-02e9ad261de5
SCIP notification number (Hungary)e3e4fe82-951e-453c-8d9a-1e47f1e3b45c
SCIP notification number (Italy)69b859ca-7aa5-448e-9028-7034acee6015
SCIP notification number (Netherlands)4cbf5e0d-e6fb-4d36-8761-6888a0c18909
SCIP notification number (Poland)64e2711a-5664-4183-950a-3a8d9900da84
SCIP notification number (Romania)672a7a97-23dc-4e7b-9b3a-6261443cdd1a
SCIP notification number (Sweden)da991a9a-9ad1-499b-aab2-d2200958a2cc

857-411: frequently asked questions

When can 857-411 be shipped?

857-411 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 857-411 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 857-411 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 857-411, subject to availability and destination.

More Wago parts

Wago 857-400 – Isolation amplifier; Current and voltage input signal; Current and voltage output signal; Zero/span adjustment; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; 2,50 m
Wago
857-400

Isolation amplifier; Current and voltage input signal; Current and voltage output signal; Zero/span adjustment; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; 2,50 m

Wago 857-401 – Isolation amplifier; Current and voltage input signal; Current and voltage output signal; Digital output; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²
Wago
857-401

Isolation amplifier; Current and voltage input signal; Current and voltage output signal; Digital output; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Wago 857-403 – Isolation amplifier; Current and voltage input signal; Bipolar current and voltage output signal; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²
Wago
857-403

Isolation amplifier; Current and voltage input signal; Bipolar current and voltage output signal; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Wago 857-409 – Isolation amplifier; Bipolar current and voltage input signal; Bipolar current and voltage output signal; Zero/span adjustment; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm modu
Wago
857-409

Isolation amplifier; Bipolar current and voltage input signal; Bipolar current and voltage output signal; Zero/span adjustment; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm modu

Wago 857-412 – Isolation amplifier; Voltage input signal; Voltage output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²
Wago
857-412

Isolation amplifier; Voltage input signal; Voltage output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Wago 857-413 – Isolation amplifier; Voltage input signal; Current output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²
Wago
857-413

Isolation amplifier; Voltage input signal; Current output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Wago 857-414 – Isolation amplifier; Voltage input signal; Current output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²
Wago
857-414

Isolation amplifier; Voltage input signal; Current output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Wago 857-415 – Isolation amplifier; Current input signal; Voltage output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²
Wago
857-415

Isolation amplifier; Current input signal; Voltage output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Wago 857-411Price and lead time confirmed within 1 business day
Request a Quote