
Relay module; Nominal input voltage: 24 … 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm
Isolation amplifier; Bipolar current and voltage input signal; Bipolar current and voltage output signal; Zero/span adjustment; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm modu
Short description:
WAGO's bipolar signal conditioner converts standard unipolar/bipolar signals, as well as amplifies, filters and electrically isolates the bipolar standard analog signals.
Features:
Overload protection of current input via resettable fuse
Zero/span adjustment across the entire measurement range
Calibrated measurement range switching
Unipolar/bipolar standard analog signals at both input/output
Switchable limit frequency
| Safety Information | Input and output must be safely isolated from any hazardous live parts! |
| Note | Use shielded signal cables!Only use shielded signal cables for analog input and output signals.This ensures the device maintains its specified accuracy and immunity to interference, even when external disturbances affect the signal cable. Use in residential areas is only permitted in conjunction with a power supply that meets the residential area criteria according to EN 61000-6-3. |
| Configuration options | DIP switch, Potentiometer |
| Input signal type | Voltage, Current |
| Input signal (voltage) | ±5 V, 0 … 5 V, 1 … 5 V, ±10 V, 0 … 10 V, 2 … 10 V |
| Input signal (current) | ±10 mA, 0 … 10 mA, 2 … 10 mA, ±20 mA, 0 … 20 mA, 4 … 20 mA |
| Input resistance (current input) | ≤ 50 Ω |
| Input resistance (voltage input) | 1 MΩ |
| Input current (max.) | 50 mA |
| Input voltage (max.) | 32 V |
| Zero/span adjustment | ±5 % of upper range value |
| Output signal type | Current, Voltage |
| Output signal (voltage) | ±5 V, 0 … 5 V, 1 … 5 V, ±10 V, 0 … 10 V, 2 … 10 V |
| Output signal (current) | ±10 mA, 0 … 10 mA, 2 … 10 mA, ±20 mA, 0 … 20 mA, 4 … 20 mA |
| Load impedance (voltage output) | ≥ 2 kΩ |
| Load impedance (current output) | ≤ 600 Ω |
| Residual ripple | ≤ 10 mV (rms) |
| Limit frequency | 100 Hz / 5 kHz (configurable via DIP switch) |
| Step response (typ.) | 3.5 ms (100 Hz), 68 µs (5 kHz) |
| Transmission error (typ.) | ≤ 0.1 % of upper-range value |
| Transmission error (max.) | ≤ 0.2 % of upper-range value |
| Transmission error (under interference) | ≤ 15 % |
| Temperature coefficient | ≤ 0.01 %/K |
| Power supply type | 24 VDC (SELV) |
| Nominal supply voltage U<sub>S</sub> | 24 VDC |
| Supply voltage range | ±30 % |
| Current consumption (default) | ≤ 20 mA |
| Current consumption (max.) | ≤ 40 mA |
| Rated voltage | 300 V |
| Protection type | IP20 |
| Test voltage (input/output/supply) | 3 kVAC; 50 Hz; 1 min |
| Overvoltage category | II |
| Pollution degree | 2 |
| Insulation type (input/analog output/supply) | Functional insulation |
| Insulation type (adjacent devices) | Reinforced insulation (safe isolation) |
| Connection technology | Push-in CAGE CLAMP® |
| Solid conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
| Fine-stranded conductor | 0.34 … 2.5 mm² / 22 … 14 AWG |
| Strip length | 9 … 10 mm / 0.35 … 0.39 inches |
| Cable type | Shielded cable |
| Width | 6 mm / 0.236 inches |
| Height | 94 mm / 3.701 inches |
| Depth from upper-edge of DIN-rail | 97.8 mm / 3.85 inches |
| Mounting type | DIN-35 rail |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire load | 0.363 MJ |
| Weight | 39.2 g |
| Ambient temperature (operation) | -25 … +70 °C |
| Ambient temperature (storage) | -40 … +85 °C |
| Processing temperature | -25 … +50 °C |
| Temperature range of connection cable | ≥ (Tambient + 10 K) |
| Relative humidity | 5 … 95 % (no condensation permissible) |
| Operating altitude (max.) | 2000 m |
| Conformity marking | CE |
| EMC immunity to interference | EN 61000-6-2 |
| EMC emission of interference | EN 61000-6-3 |
| Standards/specifications | EN 61010-1, EN 61373, DNV |
| Product Group | 6 (INTERFACE ELECTRONIC) |
| PU (SPU) | 1 pcs |
| Packaging type | bag |
| Country of origin | DE |
| GTIN | 4045454828493 |
| Customs tariff number | 85437090300 |
| UNSPSC | 32101502 |
| eCl@ss 10.0 | 27-21-01-20 |
| eCl@ss 9.0 | 27-21-01-20 |
| ETIM 9.0 | EC002653 |
| ETIM 10.0 | EC002653 |
| ECCN | NO US CLASSIFICATION |
| CAS-No. | 1303-86-2, 1317-36-8, 7439-92-1, 75980-60-8 |
| REACH Candidate List Substance | Diboron trioxide, Lead, Lead monoxide, Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)- |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | 3045ef60-f28a-43e4-9dba-b63435d5553d |
| SCIP notification number (Belgium) | 8f1d744b-8731-4270-a640-73cf63782d7f |
| SCIP notification number (Bulgaria) | 74cd0cd4-d3cc-4fa9-ac76-5a1ca5bb11a1 |
| SCIP notification number (Czech Republic) | 0689176b-e48c-48ed-859f-591c9a9bb606 |
| SCIP notification number (Denmark) | ffd652f9-d5f2-45bf-981b-f0fde66c585f |
| SCIP notification number (Finland) | 7c145b78-dbc2-4260-85cc-22a468112985 |
| SCIP notification number (France) | 3a00d327-3185-4fcb-a0b8-36a561c46061 |
| SCIP notification number (Germany) | 15951163-bfc4-44d4-b679-9146fa50b484 |
| SCIP notification number (Hungary) | 5fd6a05b-6f43-463e-8f9a-4ab07da40dfd |
| SCIP notification number (Italy) | ea8b18af-ed6a-4f27-b024-7378eb0f2d3d |
| SCIP notification number (Netherlands) | 56e8430c-ad8e-4e3a-b6f2-897614bc0f79 |
| SCIP notification number (Poland) | 62fe04e8-fd16-49c4-be93-f76f40eef9e0 |
| SCIP notification number (Romania) | 01c54ad8-3056-427f-8fc0-0b8e8c12d949 |
| SCIP notification number (Sweden) | 4527d706-aff0-40c4-95f8-d5d44d48a189 |
857-409 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Yes — mention it when you request a quote for 857-409 and we'll include express shipping options in our reply.
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 857-409, subject to availability and destination.

Relay module; Nominal input voltage: 24 … 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm

Isolation amplifier; Current and voltage input signal; Current and voltage output signal; Zero/span adjustment; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; 2,50 m

Isolation amplifier; Current and voltage input signal; Current and voltage output signal; Digital output; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Isolation amplifier; Current and voltage input signal; Bipolar current and voltage output signal; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Isolation amplifier; Current input signal; Current output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Isolation amplifier; Voltage input signal; Voltage output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Isolation amplifier; Voltage input signal; Current output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Isolation amplifier; Voltage input signal; Current output signal; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²