Siemens 7KM5412-6CA00-1EA8

SENTRON, measuring instrument and power quality recorder, 7KM PAC5200, DIN-rail enclosure without display

MPN
7KM5412-6CA00-1EA8
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 7KM5412-6CA00-1EA8?

SENTRON, measuring instrument and power quality recorder, 7KM PAC5200, DIN-rail enclosure without display, L-L: 690 V, L-N: 400 V, 10 A, DIN rail instrument, 3- phase, Modbus TCP, apparent / active / reactive energy / cos phi, harmonics: 2nd - 40th, THD, Class 0.5 acc. to IEC 61557-12 or Class 0.5 s acc. to IEC 62053-22, wide-range power supply, AC/DC, screw terminals

Specifications

Model

product brand nameSENTRON
product designationMeasuring device for power system quality measurement
design of the productAdvanced
product type designation7KM PAC5200

Measurements

measuring procedure — for voltage measurementTRMS
measuring procedure — for current measurementTRMS
type of measured value detectioncomplete
voltage curveSinusoidal or distorted
measurable line frequency — initial value45 Hz
measurable line frequency — full-scale value65 Hz
operating mode for measured value detection automatic line frequency detectionYes
operating mode for measured value detection — set at 50 HzNo
operating mode for measured value detection — set to 60 HzNo

Supply voltage

design of the power supplyWide-range power supply
type of voltage of the supply voltageAC/DC
supply voltage at AC90 ... 270 V
supply voltage at DC20 ... 300 V

Degree of protection protection class

protection class IP on the frontIP20
operating resource protection class when installedII

Suitability

suitability for operationStandard mounting rail device

Product Functions

product function — voltage measurementYes
product function — current measurementYes
product function — active power measurementYes
product function — reactive power measurementYes
product function — frequency measurementYes

Display and operation

design of the displayStandard mounting rail enclosure without display
color of the background of the displaywhite
illuminance of display backlight adjustableNo
time-controlled reduction of the illuminance of display backlight possibleNo
display contrast adjustableNo
national language on the display screen is supportedde, en
number of keys4

Communication

number of interfaces according to Fast Ethernet1
type of electrical connection of the fast Ethernet interfaceRJ45 (8P8C)

Fault limits

reference condition for metering accuracyaccording to IEC 62053-22, IEC 62053-23, IEC 62586-1, Class S, IEC 61000-4-30, IEC 61000-4-7, IEC 61000-4-15
formula for relative total measurement inaccuracy — for measured variable voltage+/- 0.2 %
formula for relative total measurement inaccuracy — for measured variable current+/- 0.2 %
formula for relative total measurement inaccuracy — for measured variable output factor+/- 0,5 %
formula for relative total measurement inaccuracy — for measured variable active energyCl. 0.5 acc. to... IEC62053-22
formula for relative total measurement inaccuracy — for measured variable reactive energyClass 2 according to IEC61557-12 and/or IEC62053-23
formula for relative total measurement inaccuracy — for measured variable THD+/- 0.5 %

Inputs Outputs

number of digital inputs0
number of digital outputs2
type of switching outputsolid state
digital output versionContinuous output, pulse output
operating voltage as output voltage at DC maximum permissible250 V
type of electrical connection at the digital outputsscrew-type terminals
output current — at digital output for signal <1> maximum300 mA
internal resistance at the digital outputs35 Ω
pulse duration — initial value50 ms
pulse duration — full-scale value3 600 000 ms
adjustable time period minimum50 ms
switching frequency at digital output maximum10 Hz
property of the output short-circuit proofYes
measuring category for digital signalsCat. III

Measuring inputs

measurable supply voltage between (PE)N and L at AC maximum rated value400 V
measurable supply voltage between the line conductors at AC maximum rated value690 V
measurable supply voltage between the line conductors at AC — maximum831 V
voltage measuring range extension with external voltage transformersyes
line conductors and neutral conductors internal resistance for voltage measurement6 MΩ
measuring category for voltage measurementCAT III
measurable current — 1 at AC rated value5 A
measurable current — 2 at AC rated value5 A
relative measurable current at AC — minimum1 %
relative measurable current at AC — maximum200 %
current measuring range extension with external current transformersYes
zero point suppression for current measurement0 ... 10 %
zero point suppression for current measurement — for neutral conductor current0.0 % to 10.0 % (from Vrated, Irated)
apparent power consumption for current measurement — with measuring range 5 A per phase2 V·A
measuring category for current measurementCATIII

Connections

type of connectable conductor cross-sections — at the measurement inputs for voltage solid2.5 mm²
type of connectable conductor cross-sections — at the measurement inputs for voltage finely stranded with core end processing2.5 mm²
type of connectable conductor cross-sections — at the measurement inputs for voltage for AWG cables solidScrew connection
type of connectable conductor cross-sections — at the measurement inputs for current solid2.5 mm²
type of connectable conductor cross-sections — at the measurement inputs for current finely stranded with core end processing2.5 mm²
type of connectable conductor cross-sections — at the measurement inputs for current for AWG cables solidScrew connection
type of electrical connection — at the measurement inputs for voltagescrew-type terminals
type of electrical connection — at the measurement inputs for currentscrew-type terminals

Mechanical Design

fastening method DIN-rail mountingYes
size of Power Monitoring DeviceDIN rail
mounting positionvertical

Environmental conditions

ambient temperature during operation — minimum-25 °C
ambient temperature during operation — maximum55 °C
ambient temperature during storage — minimum-40 °C
ambient temperature during storage — maximum70 °C
relative humidity at 25 °C without condensation during operation maximum95 %
installation altitude at height above sea level maximum2 000 m
degree of pollution2

Certificates

certificate of suitability as EC Declaration of ConformityEN 61000-6-2 and EN 61000-6-4 for EMC guideline

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

7KM5412-6CA00-1EA8: frequently asked questions

When can 7KM5412-6CA00-1EA8 be shipped?

7KM5412-6CA00-1EA8 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 7KM5412-6CA00-1EA8 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 7KM5412-6CA00-1EA8 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 7KM5412-6CA00-1EA8, subject to availability and destination.

More Siemens parts

Siemens 7KM2200-2EA40-1JB1 – SENTRON PAC2200-CLP measuring device L-L: 400 V, L-N: 230 V, 65 A direct DIN rail instrument, 6 MW
Siemens
7KM2200-2EA40-1JB1

SENTRON PAC2200-CLP measuring device L-L: 400 V, L-N: 230 V

Siemens 7KM3120-0BA01-1DA0 – SENTRON PAC3120, LCD 96 x 96 mm Power Monitoring Device
Siemens
7KM3120-0BA01-1DA0

SENTRON PAC3120, LCD 96 x 96 mm Power Monitoring Device

Siemens 7KM3120-1BA01-1EA0 – SENTRON PAC3120, LCD 96 x 96 mm Power Monitoring Device
Siemens
7KM3120-1BA01-1EA0

SENTRON PAC3120, LCD 96 x 96 mm Power Monitoring Device

Siemens 7KM9200-0AB00-0AA0 – Expansion module 4DI / 2DO, plug-in, for 7KM PAC3220/ 4220
Siemens
7KM9200-0AB00-0AA0

Expansion module 4DI / 2DO, plug-in, for 7KM PAC3220/ 4220

Siemens 7KM9300-0AE02-0AA0 – Expansion module Switched Ethernet PROFINET V3, plug-in, for 7KM PAC3220 / 4220 / 3VA COM100 / 800
Siemens
7KM9300-0AE02-0AA0

Expansion module Switched Ethernet PROFINET V3, plug-in

Siemens 7KM5412-6CA00-1EA8Price and lead time confirmed within 1 business day
Request a Quote