What is the Siemens 7KM3120-1BA01-1EA0?
SENTRON PAC3120, LCD 96 x 96 mm Power Monitoring Device, control panel instrument with measurement of electrical variables, protocol: Modbus RTU, with graphical display, Ue rated: 690/400 V, 45-65 Hz, Ie rated: X/1 A or X/5 A AC, auxiliary power: 24 ... 60 V -20/+10% DC, screw terminal connection
Specifications
Model
| product brand name | SENTRON |
| product designation | multimeter |
| design of the product | basic |
| product type designation | 7KM PAC3120 |
Measurements
| measuring procedure — for voltage measurement | TRMS |
| measuring procedure — for current measurement | TRMS |
| type of measured value detection | complete |
| voltage curve | Sinusoidal or distorted |
| measurable line frequency — initial value | 45 Hz |
| measurable line frequency — full-scale value | 65 Hz |
| operating mode for measured value detection automatic line frequency detection | Yes |
| operating mode for measured value detection — set at 50 Hz | No |
| operating mode for measured value detection — set to 60 Hz | No |
Supply voltage
| design of the power supply | Extra-low voltage power supply unit |
| type of voltage of the supply voltage | DC |
| supply voltage at DC | 24 ... 60 V |
Degree of protection protection class
| protection class IP on the front | IP65 |
Suitability
| suitability for operation | Installation in stationary panels in closed rooms |
Product Functions
| product function — voltage measurement | Yes |
| product function — current measurement | Yes |
| product function — active power measurement | Yes |
| product function — reactive power measurement | Yes |
| product function — frequency measurement | Yes |
Display and operation
| design of the display | LCD |
| height of the display | 54 mm |
| width of the display | 72 mm |
| color of the background of the display | white |
| illuminance of display backlight adjustable | No |
| time-controlled reduction of the illuminance of display backlight possible | Yes |
| display contrast adjustable | Yes |
| national language on the display screen is supported | de, en, fr, spa, ita, por, tur, chi, pol |
| number of keys | 4 |
Communication
| transfer rate minimum | 4.8 kbit/s |
| transfer rate maximum | 115.2 kbit/s |
Fault limits
| reference condition for metering accuracy | In accordance with IEC61557-12, IEC62053-22 and IEC62053-23 |
| formula for relative total measurement inaccuracy — for measured variable voltage | +/- 0.2 % |
| formula for relative total measurement inaccuracy — for measured variable current | +/- 0.2 % |
| formula for relative total measurement inaccuracy — for measured variable active power | +/- 0.5 % |
| formula for relative total measurement inaccuracy — for measured variable reactive power | +/- 1 % |
| formula for relative total measurement inaccuracy — for measured variable output factor | +/- 0,5 % |
| formula for relative total measurement inaccuracy — for measured variable active energy | Cl. 0.5 acc. to... IEC62053-22 |
| formula for relative total measurement inaccuracy — for measured variable reactive energy | Class 2 according to IEC61557-12 and/or IEC62053-23 |
Inputs Outputs
| number of digital inputs | 2 |
| type of electrical connection at the digital inputs | screw-type terminals |
| operating conditions for digital inputs external voltage supply | Yes |
| input voltage at digital input at DC maximum | 30 V |
| input current at digital input — initial value for signal<1>-recognition | 7 mA |
| number of digital outputs | 2 |
| type of switching output | bidirectional |
| digital output version | switching or pulse output function |
| operating voltage as output voltage at DC maximum permissible | 30 V |
| type of electrical connection at the digital outputs | screw-type terminals |
| output current — at the digital outputs at DC limited to 100 ms maximum | 130 mA |
| internal resistance at the digital outputs | 55 Ω |
| standard for pulse emitter | according to IEC62053-31 |
| pulse duration — initial value | 30 ms |
| pulse duration — full-scale value | 500 ms |
| adjustable time period minimum | 10 ms |
| switching frequency at digital output maximum | 17 Hz |
| property of the output short-circuit proof | Yes |
Measuring inputs
| measurable supply voltage between (PE)N and L at AC maximum rated value | 400 V |
| measurable supply voltage between (PE)N and L at AC — minimum | 11.5 V |
| measurable supply voltage between (PE)N and L at AC — maximum | 480 V |
| measurable supply voltage between the line conductors at AC maximum rated value | 690 V |
| voltage measuring range extension with external voltage transformers | yes |
| line conductors and neutral conductors internal resistance for voltage measurement | 1.5 MΩ |
| measuring category for voltage measurement | CAT III |
| measurable current — 1 at AC rated value | 1 A |
| measurable current — 2 at AC rated value | 5 A |
| relative measurable current at AC at energy and power measurement — minimum | 1 % |
| relative measurable current at AC at energy and power measurement — maximum | 120 % |
| relative measurable current at AC — minimum | 10 % |
| relative measurable current at AC — maximum | 100 % |
| current measuring range extension with external current transformers | Yes |
| zero point suppression for current measurement | 0 ... 10 % |
| apparent power consumption for current measurement — with measuring range 5 A per phase | 0.3 V·A |
| measuring category for current measurement | CATIII |
Connections
| type of electrical connection — at the measurement inputs for voltage | screw-type terminals |
| type of electrical connection — at the measurement inputs for current | screw-type terminals |
Mechanical Design
| fastening method DIN-rail mounting | No |
| size of Power Monitoring Device | size 96 |
| height | 96 mm |
| width | 96 mm |
| depth | 56 mm |
| installation depth | 51 mm |
| mounting position | vertical |
Environmental conditions
| ambient temperature during operation — minimum | -25 °C |
| ambient temperature during operation — maximum | 55 °C |
| ambient temperature during storage — minimum | -25 °C |
| ambient temperature during storage — maximum | 70 °C |
| relative humidity at 25 °C without condensation during operation maximum | 75 % |
| installation altitude at height above sea level maximum | 2 000 m |
| degree of pollution | 2 |
Certificates
| certificate of suitability as EC Declaration of Conformity | yes |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
7KM3120-1BA01-1EA0: frequently asked questions
When can 7KM3120-1BA01-1EA0 be shipped?
7KM3120-1BA01-1EA0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 7KM3120-1BA01-1EA0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 7KM3120-1BA01-1EA0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 7KM3120-1BA01-1EA0, subject to availability and destination.
More Siemens parts