Siemens 6ES7214-1BG40-0XB0 – SIMATIC S7-1200, CPU 1214C, compact CPU, AC/DC/relay
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | CPU 1214C |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.45 kg |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can 6ES7214-1BG40-0XB0 be shipped?
6ES7214-1BG40-0XB0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6ES7214-1BG40-0XB0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6ES7214-1BG40-0XB0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6ES7214-1BG40-0XB0, subject to availability and destination.
SIMATIC S7-1200, CPU 1214C, compact CPU, AC/DC/relay, onboard I/O: 14 DI 24 V DC; 10 DO relay 2 A; 2 AI 0-10 V DC, power supply: AC 85-264 V AC at 47-63 Hz, program/data memory 150 KB
Specifications
General information
| Product type designation | CPU 1214C AC/DC/relay |
| Firmware version | V4.7 |
| Programming package | STEP 7 V20 or higher |
Supply voltage
| Rated value (AC) – 120 V AC | Yes |
| Rated value (AC) – 230 V AC | Yes |
| permissible range, lower limit (AC) | 85 V |
| permissible range, upper limit (AC) | 264 V |
| permissible range, lower limit | 47 Hz |
| permissible range, upper limit | 63 Hz |
Input current
| Current consumption (rated value) | 100 mA at 120 V AC; 50 mA at 240 V AC |
| Current consumption, max. | 300 mA at 120 V AC; 150 mA at 240 V AC |
| Inrush current, max. | 20 A; at 264 V |
| I²t | 0.8 A²·s |
Output current
| for backplane bus (5 V DC), max. | 1 600 mA; Max. 5 V DC for SM and CM |
Encoder supply
| 24 V | 20.4 to 28.8V |
Power loss
| Power loss, typ. | 14 W |
Storage
| integrated | 150 kbyte |
| integrated | 4 Mbyte |
| Plug-in (SIMATIC Memory Card), max. | with SIMATIC memory card |
| present | Yes |
| maintenance-free | Yes |
| without battery | Yes |
CPU processing times
| for bit operations, typ. | 0.08 µs; / instruction |
| for word operations, typ. | 1.7 µs; / instruction |
| for floating point arithmetic, typ. | 2.3 µs; / instruction |
CPU-blocks
| Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
| Number, max. | Limited only by RAM for code |
Data areas and their retentivity
| Retentive data area (incl. timers, counters, flags), max. | 14 kbyte |
| Size, max. | 8 kbyte; Size of bit memory address area |
| per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
Address area
| Inputs, adjustable | 1 kbyte |
| Outputs, adjustable | 1 kbyte |
Hardware configuration
| Number of modules per system, max. | 3 comm. modules, 1 signal board, 8 signal modules |
| number of expansion boards (SB, CB, BB) | 1 |
| number of signal modules (SM) | 8 |
| number of communications modules (CM) | 3 |
Time of day
| Hardware clock (real-time) | Yes |
| Backup time | 480 h; Typical |
| Deviation per day, max. | ±60 s/month at 25 °C |
Digital inputs
| Number of digital inputs | 14; Integrated |
| of which inputs usable for technological functions | 6; HSC (High Speed Counting) |
| Sourcing/sinking input | Yes |
| — up to 40 °C, max. | 14 |
| Rated value (DC) | 24 V |
| for signal "0" | 5 V DC at 1 mA |
| for signal "1" | 15 V DC at 2.5 mA |
| — parameterizable | 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms |
| — at "0" to "1", min. | 0.2 ms |
| — at "0" to "1", max. | 12.8 ms |
| — parameterizable | Yes |
| — Parameterizable | Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz |
| shielded, max. | 500 m; 50 m for technological functions |
| unshielded, max. | 300 m; for technological functions: No |
Digital outputs
| Number of digital outputs | 10; Relays |
| with resistive load, max. | 2 A |
| on lamp load, max. | 30 W with DC, 200 W with AC |
| "0" to "1", max. | 10 ms; max. |
| "1" to "0", max. | 10 ms; max. |
| Number of relay outputs | 10 |
| Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100 000 |
| shielded, max. | 500 m |
| unshielded, max. | 150 m |
Analog inputs
| Number of analog inputs | 2 |
| Voltage | Yes |
| 0 to +10 V | Yes |
| — Input resistance (0 to 10 V) | ≥100k ohms |
| shielded, max. | 100 m; twisted and shielded |
Analog outputs
| Number of analog outputs | 0 |
Analog value generation for the inputs
| Resolution with overrange (bit including sign), max. | 10 bit |
| Integration time, parameterizable | Yes |
| Conversion time (per channel) | 625 µs |
Encoder
| 2-wire sensor | Yes |
Interfaces
| Number of PROFINET interfaces | 1 |
1. Interface
| Interface type | PROFINET |
| Isolated | Yes |
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| RJ 45 (Ethernet) | Yes |
| Number of ports | 1 |
| integrated switch | No |
| PROFINET IO Controller | Yes |
| PROFINET IO Device | Yes |
| SIMATIC communication | Yes |
| Open IE communication | Yes; Optionally also encrypted |
| Web server | Yes |
| Media redundancy | No |
| Transmission rate, max. | 100 Mbit/s |
| — PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| — Isochronous mode | No |
| — IRT | No |
| — PROFIenergy | No |
| — Prioritized startup | Yes |
| — Number of IO devices with prioritized startup, max. | 16 |
| — Number of connectable IO Devices, max. | 16 |
| — Number of connectable IO Devices for RT, max. | 16 |
| — of which in line, max. | 16 |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
| — Updating time | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
| — PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| — Isochronous mode | No |
| — IRT | No |
| — Dynamic Frame Packing (DFP) | No |
| — PROFIenergy | Yes |
| — Prioritized startup | Yes |
| — Shared device | Yes |
| — Number of IO Controllers with shared device, max. | 2 |
| — Asset management record | Yes |
Protocols
| Supports protocol for PROFINET IO | Yes |
| PROFIsafe | No |
| PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required |
| OPC UA | Yes; OPC UA Server |
| AS-Interface | Yes; CM 1243-2 required |
| TCP/IP | Yes |
| DHCP | No |
| SNMP | Yes |
| DCP | Yes |
| LLDP | Yes |
| PROFINET system redundancy (S2) | No |
| PROFINET system redundancy (R1) | No |
| — MRP | No |
| — MRP interconnection, supported | No |
| — MRPD | No |
| S7 routing | Yes |
| TCP/IP | Yes |
| — Data length, max. | 8 kbyte |
| ISO-on-TCP (RFC1006) | Yes |
| — Data length, max. | 8 kbyte |
| UDP | Yes |
| — Data length, max. | 1 472 byte |
| supported | Yes |
| User-defined websites | Yes |
| Runtime license required | Yes; "Basic" license required |
| OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required |
| — Application authentication | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| — User authentication | "anonymous" or by user name & password |
| — Number of sessions, max. | 10 |
| — Number of subscriptions per session, max. | 5 |
| — Sampling interval, min. | 100 ms |
| — Publishing interval, min. | 200 ms |
| — Number of server methods, max. | 20 |
| — Number of monitored items, recommended max. | 1 000 |
| — Number of server interfaces, max. | 2 |
| — Number of nodes for user-defined server interfaces, max. | 2 000 |
| MODBUS | Yes |
Communication functions
| supported | Yes |
| as server | Yes |
| as client | Yes |
| User data per job, max. | See online help (S7 communication, user data size) |
| overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 68 max |
Test commissioning functions
| Status/control variable | Yes |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Forcing | Yes |
| present | Yes |
| Number of configurable Traces | 2 |
| Memory size per trace, max. | 512 kbyte |
Interrupts/diagnostics/status information
| RUN/STOP LED | Yes |
| ERROR LED | Yes |
| MAINT LED | Yes |
Integrated Functions
| Counter – Number of counters | 6 |
| Counter – Counting frequency, max. | 100 kHz |
| Frequency measurement | Yes |
| controlled positioning | Yes |
| Number of position-controlled positioning axes, max. | 8 |
| Number of positioning axes via pulse-direction interface | Up to 4 with SB 1222 |
| PID controller | Yes |
| Number of alarm inputs | 4 |
Potential separation
| Potential separation digital inputs | 500 V AC for 1 minute |
| between the channels, in groups of | 1 |
| Potential separation digital outputs | Relays |
| between the channels | No |
| between the channels, in groups of | 2 |
EMC
| Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
| — Test voltage at air discharge | 8 kV |
| — Test voltage at contact discharge | 6 kV |
| Interference immunity on supply lines acc. to IEC 61000-4-4 | Yes |
| Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes |
| Interference immunity on supply lines acc. to IEC 61000-4-5 | Yes |
| Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes |
| Limit class A, for use in industrial areas | Yes; Group 1 |
| Limit class B, for use in residential areas | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection
| IP degree of protection | IP20 |
Standards, approvals, certificates
| Siemens Eco Profile (SEP) | Siemens EcoTech |
| CE mark | Yes |
| UL approval | Yes |
| cULus | Yes |
| FM approval | Yes |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| Marine approval | Yes |
| environmental product declaration | Yes; type II acc. to ISO 14021 |
| — global warming potential, (total) [CO2 eq] | 111 kg |
| — global warming potential, (during production) [CO2 eq] | 20.1 kg |
| — global warming potential, (during operation) [CO2 eq] | 91.5 kg |
| — global warming potential, (after end of life cycle) [CO2 eq] | -0.9 kg |
Ambient conditions
| Fall height, max. | 0.3 m; five times, in product package |
| min. | -20 °C |
| max. | 60 °C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or 10 at 55 °C horizontal or 45 °C vertical |
| horizontal installation, min. | -20 °C |
| horizontal installation, max. | 60 °C |
| vertical installation, min. | -20 °C |
| vertical installation, max. | 50 °C |
| min. | -40 °C |
| max. | 70 °C |
| Operation, min. | 795 hPa |
| Operation, max. | 1 080 hPa |
| Storage/transport, min. | 660 hPa |
| Storage/transport, max. | 1 080 hPa |
| Installation altitude, min. | -1 000 m |
| Installation altitude, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Operation, max. | 95 %; no condensation |
| Vibration resistance during operation acc. to IEC 60068-2-6 | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail |
| Operation, tested according to IEC 60068-2-6 | Yes |
| tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
| SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60 % condensation-free |
Configuration
| — LAD | Yes |
| — FBD | Yes |
| — SCL | Yes |
| User program protection/password protection | Yes |
| Copy protection | Yes |
| Block protection | Yes |
| protection of confidential configuration data | Yes |
| Protection level: Write protection | Yes |
| Protection level: Read/write protection | Yes |
| Protection level: Complete protection | Yes |
| User administration | Yes; device-wide |
| Number of users | 42 |
| Number of groups | 14 |
| Number of roles | 20 |
| adjustable | Yes |
Dimensions
| Width | 110 mm |
| Height | 100 mm |
| Depth | 75 mm |
Weights
| Weight, approx. | 455 g |
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet 6ES7214-1BG40-0XB0 |
More Siemens parts
Available on requestSiemens 6ES7212-1BG50-0XB0 – SIMATIC S7-1200 G2: compact CPU 1212C AC/DC/RLY
Available on requestSiemens 6ES7212-1HE40-0XB0 – SIMATIC S7-1200, CPU 1212C, compact CPU, DC/DC/relay
Available on requestSiemens 6ES7212-1HF40-0XB0 – SIMATIC S7-1200, CPU 1212FC, compact CPU, DC/DC/relay
Available on requestSiemens 6ES7214-1AF40-0XB0 – SIMATIC S7-1200F, CPU 1214 FC, compact CPU, DC/DC/DC
Available on requestSiemens 6ES7214-1BH50-0XB0 – SIMATIC S7-1200 G2: compact CPU 1214C AC/DC/RLY
Available on requestSiemens 6ES7215-1AG40-0XB0 – SIMATIC S7-1200, CPU 1215C, compact CPU, DC/DC/DC
Available on requestSiemens 6ES7215-1BG40-0XB0 – SIMATIC S7-1200, CPU 1215C, compact CPU, AC/DC/relay
Available on requestSiemens 6ES7221-1BF32-0XB0 – SIMATIC S7-1200, Digital input SM 1221, 8 DI, 24 V DC