Siemens 6ES7214-1BH50-0XB0 – SIMATIC S7-1200 G2: compact CPU 1214C AC/DC/RLY
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | CPU 1214C |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.42 kg |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can 6ES7214-1BH50-0XB0 be shipped?
6ES7214-1BH50-0XB0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6ES7214-1BH50-0XB0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6ES7214-1BH50-0XB0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6ES7214-1BH50-0XB0, subject to availability and destination.
SIMATIC S7-1200 G2: compact CPU 1214C AC/DC/RLY; power supply: AC 85-264 V AC at 47-63 Hz; onboard I/O: 14x DI 24 V DC; 10 DO relay 2 A; memory: program 250 KB data: 750 KB, retentivity: 20 KB
Specifications
General information
| Product type designation | CPU 1214C AC/DC/Relay |
| Firmware version | V4.1 |
| FW update possible | Yes |
| I&M data | Yes; I&M0 to I&M3 |
| Isochronous mode | Yes; For PROFINET only |
| SysLog | Yes |
| Programming package | STEP 7 V21 or higher |
Supply voltage
| Rated value (AC) – 120 V AC | Yes |
| Rated value (AC) – 230 V AC | Yes |
| permissible range, lower limit (AC) | 85 V |
| permissible range, upper limit (AC) | 264 V |
| permissible range, lower limit | 47 Hz |
| permissible range, upper limit | 63 Hz |
Input current
| Current consumption (rated value) | 80 mA at 120 V AC; 44 mA at 240 V AC |
| Current consumption, max. | 480 mA at 120 V AC; 275 mA at 240 V AC |
| Inrush current, max. | 20 A; at 264 V |
| I²t | 0.8 A²·s |
Output current
| for backplane bus (5 V DC), max. | 1 600 mA; Max. 5 V DC for SM and CM |
Encoder supply
| 24 V | Yes; 20.4 to 28.8V |
| Short-circuit protection | Yes |
| Output current, max. | 400 mA |
Power loss
| Power loss, typ. | 4 W |
Storage
| integrated | 1 000 kbyte |
| integrated (for program) | 250 kbyte |
| integrated (for data) | 750 kbyte |
| integrated | 8 Mbyte |
| Plug-in (SIMATIC Memory Card), max. | 32 Gbyte; with SIMATIC memory card |
| present | Yes |
| maintenance-free | Yes |
| without battery | Yes |
CPU processing times
| for bit operations, typ. | 37 ns; / instruction |
| for word operations, typ. | 30 ns; / instruction |
| for floating point arithmetic, typ. | 74 ns; / instruction |
CPU-blocks
| Number of elements (total) | 4 000; Blocks (OB, FB, FC, DB) and UDTs |
| Number of free cycle OBs | 100 |
| Number of time alarm OBs | 20 |
| Number of delay alarm OBs | 20 |
| Number of cyclic interrupt OBs | 20; with minimum OB 3x cycle of 1 ms |
| Number of process alarm OBs | 50 |
| Number of DPV1 alarm OBs | 3 |
| Number of isochronous mode OBs | 1 |
| Number of startup OBs | 100 |
| Number of asynchronous error OBs | 4 |
| Number of synchronous error OBs | 2 |
| Number of diagnostic alarm OBs | 1 |
Data areas and their retentivity
| Retentive data area (incl. timers, counters, flags), max. | 20 kbyte |
| Size, max. | 8 kbyte; Size of bit memory address area |
| per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area
| Inputs | 1 kbyte; All inputs are in the process image |
| Outputs | 1 kbyte; All outputs are in the process image |
| Inputs, adjustable | 1 kbyte |
| Outputs, adjustable | 1 kbyte |
Hardware configuration
| Number of modules per system, max. | 10 |
| number of expansion boards (SB, CB, BB) | 2 |
| number of signal modules (SM) | 10; depends on the number of CMs |
| number of communications modules (CM) | 3 |
Time of day
| Hardware clock (real-time) | Yes |
| Backup time | 480 h; Typical |
| Deviation per day, max. | 2 s; at 25 °C |
| on Ethernet via NTP | Yes |
Digital inputs
| Number of digital inputs | 14; Integrated |
| of which inputs usable for technological functions | 8; HSC (High Speed Counting) |
| Sourcing/sinking input | Yes |
| — up to 40 °C, max. | 14 |
| Rated value (DC) | 24 V |
| for signal "0" | 5 V DC or 0.5 mA |
| for signal "1" | 15 V DC at 2.5 mA |
| — parameterizable | 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms |
| — at "0" to "1", min. | 0.1 µs |
| — at "0" to "1", max. | 20 µs |
| — Parameterizable | Yes |
| — Parameterizable | single phase: 6 HSCs @ 100 kHz & 2 standard @ 30 kHz, quadrature phase: 6 HSCs @ 80 kHz & 2 standard @ 20 kHz |
| shielded, max. | 500 m; 50 m for technological functions |
| unshielded, max. | 300 m; for technological functions: No |
Digital outputs
| Number of digital outputs | 10; Relays |
| with resistive load, max. | 2 A |
| on lamp load, max. | 30 W with DC, 200 W with AC |
| "0" to "1", max. | 10 ms; max. |
| "1" to "0", max. | 10 ms; max. |
| of the pulse outputs, with resistive load, max. | Not recommended |
| Number of relay outputs | 10 |
| Number of operating cycles, max. | mechanically 10 million, at rated load voltage 100 000 |
| shielded, max. | 500 m |
| unshielded, max. | 150 m |
Analog inputs
| Number of analog inputs | 0 |
Analog outputs
| Number of analog outputs | 0 |
Encoder
| 2-wire sensor | Yes |
Interfaces
| Number of PROFINET interfaces | 1 |
1. Interface
| Interface type | PROFINET |
| Isolated | Yes |
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| RJ 45 (Ethernet) | Yes; X1 |
| — Transmission rate, max. | 100 Mbit/s |
| Number of ports | 2 |
| integrated switch | Yes |
| IP protocol | Yes; IPv4 |
| PROFINET IO Controller | Yes |
| PROFINET IO device | Yes |
| SIMATIC communication | Yes |
| Open IE communication | Yes; Optionally also encrypted |
| Web server | Yes |
| Media redundancy | Yes |
| Transmission rate, max. | 100 Mbit/s |
| — PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| — Isochronous mode | Yes |
| — IRT | Yes |
| — Dynamic Frame Packing (DFP) | Yes |
| — PROFIenergy | Yes; per user program |
| — Prioritized startup | Yes |
| — Number of IO devices with prioritized startup, max. | 16 |
| — Number of connectable IO Devices, max. | 31 |
| — Of which IO devices with IRT, max. | 31 |
| — Number of connectable IO Devices for RT, max. | 31 |
| — of which in line, max. | 31 |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
| — Updating time | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
| — for send cycle of 1 ms | 1 ms to 16 ms |
| — for send cycle of 2 ms | 2 ms to 32 ms |
| — for send cycle of 4 ms | 4 ms to 64 ms |
| — for send cycle of 1 ms | 1 ms to 512 ms |
| — for send cycle of 2 ms | 2 ms to 512 ms |
| — for send cycle of 4 ms | 4 ms to 512 ms |
| — PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| — Isochronous mode | No |
| — IRT | Yes |
| — Dynamic Frame Packing (DFP) | No |
| — PROFIenergy | Yes; per user program |
| — Prioritized startup | Yes |
| — Shared device | Yes |
| — Number of IO Controllers with shared device, max. | 2 |
| — Asset management record | Yes |
Protocols
| Supports protocol for PROFINET IO | Yes |
| PROFIsafe | No |
| PROFIBUS | No |
| OPC UA | Yes; OPC UA Server |
| AS-Interface | No |
| TCP/IP | Yes |
| DHCP | Yes |
| SNMP | Yes |
| DCP | Yes |
| LLDP | Yes |
| Number of connections, max. | 128; via integrated interfaces of the CPU and connected CPs / CMs |
| Number of connections reserved for ES/HMI/web | 10 |
| Number of connections via integrated interfaces | 88 |
| Number of S7 routing paths | 16 |
| PROFINET system redundancy (S2) | No |
| PROFINET system redundancy (R1) | No |
| — MRP | Yes; as MRP redundancy manager and/or MRP client |
| — MRP interconnection, supported | Yes |
| — MRPD | Yes; Requirement: IRT |
| — Number of stations in the ring, max. | 50 |
| PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| S7 routing | Yes |
| S7 communication, as server | Yes |
| S7 communication, as client | Yes; only PUT/GET |
| User data per job, max. | See online help (S7 communication, user data size) |
| TCP/IP | Yes |
| — Data length, max. | 64 kbyte |
| — several passive connections per port, supported | Yes |
| ISO-on-TCP (RFC1006) | Yes |
| — Data length, max. | 64 kbyte |
| UDP | Yes |
| — Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
| DHCP | Yes |
| DNS | Yes |
| SNMP | Yes |
| DCP | Yes |
| LLDP | Yes |
| Encryption | Yes; Optional |
| supported | Yes |
| HTTPS | Yes |
| web API | Yes |
| — Number of sessions, max. | 30 |
| — HTTP request body, max. | 131 072 byte |
| User-defined websites | Yes |
| Runtime license required | Yes; "Basic" license required |
| OPC UA Server | Yes; data access (read, write, subscribe), method call, runtime license required |
| — Application authentication | Yes |
| — Security policies | available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss |
| — User authentication | "anonymous" or by user name & password |
| — Number of sessions, max. | 10 |
| — Number of subscriptions per session, max. | 5 |
| — Sampling interval, min. | 100 ms |
| — Publishing interval, min. | 200 ms |
| — Number of server methods, max. | 20 |
| — Number of monitored items, recommended max. | 1 000 |
| — Number of server interfaces, max. | 2 |
| — Number of nodes for user-defined server interfaces, max. | 2 000 |
| MODBUS | Yes; MODBUS RTU/TCP |
Communication functions
| supported | Yes |
| as server | Yes |
| as client | Yes |
| User data per job, max. | See online help (S7 communication, user data size) |
| overall | PG Connections: 4 reserved; HMI Connections: 4 reserved / 82 max; S7 Connections: 78 max; Open User Connections: 78 max; Web Connections: 2 reserved / 80 max; Total Connections: 10 reserved / 88 max |
| overall | PG Connections: 4 reserved; HMI Connections: 4 reserved / 82 max; S7 Connections: 78 max; Open User Connections: 78 max; Web Connections: 2 reserved / 80 max; Total Connections: 10 reserved / 88 max |
S7 message functions
| Number of login stations for message functions, max. | 32 |
| number of subscriptions, max. | 250 |
| number of tags/attributes for subscriptions, max. | 2 000 |
| Program alarms | Yes |
| Number of configurable program messages, max. | 5 000 |
| Number of loadable program messages in RUN, max. | 2 500 |
| Number of simultaneously active program alarms – Number of program alarms | 600 |
| Number of simultaneously active program alarms – Number of alarms for system diagnostics | 100 |
| Number of simultaneously active program alarms – Number of alarms for motion technology objects | 160 |
Test commissioning functions
| Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
| Single step | No |
| Profiling | Yes |
| Status/control variable | Yes |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max. – — of which status variables, max. | 200; per job |
| Number of variables, max. – — of which control variables, max. | 200; per job |
| Number of variables, max. – Forcing | Yes |
| Number of variables, max. – Forcing, variables | Peripheral inputs/outputs |
| Number of variables, max. – Number of variables, max. | 200 |
| Number of variables, max. – present | Yes |
| Number of variables, max. – Number of entries, max. | 500 |
| Number of variables, max. – — of which powerfail-proof | 100 |
| Number of variables, max. – Number of configurable Traces | 4 |
| Number of variables, max. – Memory size per trace, max. | 512 kbyte |
Interrupts/diagnostics/status information
| RUN/STOP LED | Yes |
| ERROR LED | Yes |
| MAINT LED | Yes |
Supported technology objects
| Motion Control | Yes |
| Number of available Motion Control resources for technology objects | 800 |
| Required Motion Control resources – — per speed-controlled axis | 40 |
| Required Motion Control resources – — per positioning axis | 80 |
| Required Motion Control resources – — per synchronous axis | 160 |
| Required Motion Control resources – — per external encoder | 80 |
| Required Motion Control resources – — per output cam | 20 |
| Required Motion Control resources – — per cam track | 160 |
| Required Motion Control resources – — per probe | 40 |
| Required Motion Control resources – Number of available Extended Motion Control resources for technology objects | 40 |
| Required Extended Motion Control resources – — per cam (1 000 points and 50 segments) | 2 |
| Required Extended Motion Control resources – — for each set of kinematics | 30 |
| kinematics functions – — kinematics with up to 4 interpolating axes | Yes |
| kinematics functions – — kinematics with 5 or more interpolating axes | No |
| kinematics functions – — user-defined kinematics | No |
| kinematics functions – — SIMATIC Safe Kinematics | No |
| Positioning axis – — Number of positioning axes at motion control cycle of 4 ms (typical value) | 10 |
| Positioning axis – — Number of positioning axes at motion control cycle of 8 ms (typical value) | 10 |
Integrated Functions
| Counter | Yes |
| Number of counters | 8 |
| Counting frequency, max. | 100 kHz; Ia.0 to Ia.5: 100 kHz (80 kHz in quadrature mode), Ia.6 to Ib.5: 30 kHz (20 kHz in quadrature mode) |
| Frequency measurement | Yes |
| controlled positioning | Yes |
| Number of position-controlled positioning axes, max. | 8 |
| Number of positioning axes via pulse-direction interface | Up to 4 with SB 1222 |
| PID controller | Yes |
| Number of pulse outputs | 8; individually assigned to CPU and Signal Board |
| Limit frequency (pulse) | 100 kHz |
Potential separation
| Potential separation digital inputs | Yes; field side to logic: 707 V DC (type test) |
| between the channels | No |
| Number of potential groups | 1 |
| Potential separation digital outputs | Relays |
| between the channels | No |
| Number of potential groups | 1 |
EMC
| Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
| — Test voltage at air discharge | 8 kV |
| — Test voltage at contact discharge | 6 kV |
| Interference immunity on supply lines acc. to IEC 61000-4-4 | Yes |
| Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes |
| Interference immunity on supply lines acc. to IEC 61000-4-5 | Yes |
| Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes |
| Limit class A, for use in industrial areas | Yes; Group 1 |
| Limit class B, for use in residential areas | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection
| IP degree of protection | IP20 |
Standards, approvals, certificates
| Siemens Eco Profile (SEP) | Siemens EcoTech |
| CE mark | Yes |
| UL approval | Yes |
| cULus | Yes |
| FM approval | No |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| Marine approval | Yes |
| environmental product declaration | Yes; type 2 acc. to ISO 14021 |
| — global warming potential, (total) [CO2 eq] | 68 kg |
| — global warming potential, (during production) [CO2 eq] | 14.4 kg |
| — global warming potential, (during operation) [CO2 eq] | 54.2 kg |
| — global warming potential, (after end of life cycle) [CO2 eq] | -0.72 kg |
Security
| PROFINET Security Class | 1 |
| signed firmware update | Yes |
| Secure Boot | Yes |
Ambient conditions
| Fall height, max. | 0.3 m; five times, in product package |
| min. | -20 °C; No condensation |
| max. | 40 °C; 40 °C horizontal or 30 °C vertical at max. voltages and max. specifications |
| horizontal installation, min. | -20 °C; No condensation |
| horizontal installation, max. | 60 °C; at rated voltages, 50 % of max. specification and alternate IO active |
| vertical installation, min. | -20 °C; No condensation |
| vertical installation, max. | 50 °C; at rated voltages, 50 % of max. specification and alternate IO active |
| min. | -40 °C |
| max. | 70 °C |
| Operation, min. | 540 hPa |
| Operation, max. | 1 140 hPa |
| Storage/transport, min. | 540 hPa |
| Storage/transport, max. | 1 140 hPa |
| Installation altitude, min. | -1 000 m |
| Installation altitude, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Operation, max. | 95 %; no condensation |
| Vibration resistance during operation acc. to IEC 60068-2-6 | 3.5 mm from 5 - 8.4 Hz, 1g from 8.4 - 150 Hz |
| Operation, tested according to IEC 60068-2-6 | Yes |
| tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
| SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60 % condensation-free |
| SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60 % condensation-free |
Configuration
| — LAD | Yes |
| — FBD | Yes |
| — SCL | Yes |
| User program protection/password protection | Yes |
| Copy protection | No |
| Block protection | Yes |
| protection of confidential configuration data | Yes |
| Protection level: Write protection | Yes |
| Protection level: Read/write protection | Yes |
| Protection level: Complete protection | Yes |
| User administration | Yes; device-wide and centralized |
| Number of users | 100 |
| Number of groups | 100 |
| Number of roles | 50 |
| adjustable | Yes |
Dimensions
| Width | 80 mm |
| Height | 125 mm |
| Depth | 100 mm |
Weights
| Weight, approx. | 417 g |
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet 6ES7214-1BH50-0XB0 |
More Siemens parts
Available on requestSiemens 6ES7212-1HE40-0XB0 – SIMATIC S7-1200, CPU 1212C, compact CPU, DC/DC/relay
Available on requestSiemens 6ES7212-1HF40-0XB0 – SIMATIC S7-1200, CPU 1212FC, compact CPU, DC/DC/relay
Available on requestSiemens 6ES7214-1AF40-0XB0 – SIMATIC S7-1200F, CPU 1214 FC, compact CPU, DC/DC/DC
Available on requestSiemens 6ES7214-1BG40-0XB0 – SIMATIC S7-1200, CPU 1214C, compact CPU, AC/DC/relay
Available on requestSiemens 6ES7215-1AG40-0XB0 – SIMATIC S7-1200, CPU 1215C, compact CPU, DC/DC/DC
Available on requestSiemens 6ES7215-1BG40-0XB0 – SIMATIC S7-1200, CPU 1215C, compact CPU, AC/DC/relay
Available on requestSiemens 6ES7221-1BF32-0XB0 – SIMATIC S7-1200, Digital input SM 1221, 8 DI, 24 V DC
Available on requestSiemens 6ES7221-1BH32-0XB0 – SIMATIC S7-1200, Digital input SM 1221, 16 DI, 24 V DC